![Creavit ES2210 Installation Instruction Download Page 7](http://html.mh-extra.com/html/creavit/es2210/es2210_installation-instruction_2681728007.webp)
DESCRIPTION
MALFUNCTION CAUSE
TREATMENT
no water out
the battery is exhausted(DC item)
change the battery
water supply cut off
check supply
dirt in the filter
clean the filter
water pressure is too low
raise the pressure
water will not turn off
dirt on the sensor window
clear the dirt
too little water flow
water supply is turned too small
adjust water supply
the filter is too dirty
clean the filter
water pressure is too low
raise the pressure
too much water flow
water supply is turned too high
adjust supply
water pressure is too high
adjust pressure
short cycles of battery
incorrect batteries
change to 4AA alkaline battery
the indicator
light is not on
the light is broken
change the light or circuitry board
the circuitry board is wet or signal line is wet
dry out
the battery is exhausted
change the battery
poor connection of battery
check the battery connection