![Creator CRT-531 Series Product Specification Download Page 8](http://html.mh-extra.com/html/creator/crt-531-series/crt-531-series_product-specification_2681705008.webp)
SPECIFICATION
Model No.
CRT-531
Date
2010-2-1
Card Dispenser
Ver.
3.0
Page
8/13
4.4 Extend
CRT Command
C
Parameter
Return
Comment
“FC”+ Position
<06H>
Card stop on the specified position
,
,
1
,
2
,
3
,
4
,
5
,
6} parameter:
0x30,0x34,0x33,0x32,0x31,0x36,0x37}
“CS”+ Position
<06H>
Set up Baud rate.(0-5,
indicate 1200BPS-38400BPS)
“IN”+ Parameter
<06H>
Setting of card inserted from
dispenser mouth:
Parameter
=0x30 Prohibit cards in
=0x31 Allow cards into error card bin
=0x32 Allow cards into card
read/write position (I.e. card stop
location 2)
“SI”
SI +Parameter(similar
to RF command returned)
Check the setting status of card
inserted from the dispenser mouth
Note
: (
1
)
“
4
”
is the position for card pre-dispense, program will execute “pre-dispense”
automatically(Except press “Reset” keystoke on the dispenser by hand); Execute “FC+4”, no any
reaction for this command, and this will cause unpredictable damage, so please don’t use this
command in a hurry.
(2)The operation of checking status for “SI” inserting card from dispenser mouth is similar to
“RF” and “AP”. The parameter of command returned with 1byte is same as the “IN”parameter.
(3) “IN” is a operation command for EEPRON. The setting status will not be affected even if
it is power on or reset, that means the last setting is still valid when power on. And It is defaulted
that the card is captured to the error card bin when ex-work.
4.5 Specification of photoelectricity sensor and card stop location
4.3.1 Definition of graph
Card Stop Location
photoelectricity sensor
photoelectricity sensor preserved
4.5.2 Sketch map of card stop location and photoelectricity sensor
n
n