CLS Atmosphere LED panel

Protection from burns and fire

• Provide a clearance of at least 26mm at the back of the unit.

• Do not install the CLS Atmosphere Panel near a heat source.

• Do not install this CLS Atmosphere Panel in a corrosive, flammable or explosive area.

• Do not modify the CLS Atmosphere Panel, or install other than genuine parts.

• Do not operate the CLS Atmosphere Panel if the ambient temperature exceeds 40 ºC.

Protection from injury due falls

• Verify that all covers and mounting hardware is securely fastened

• Block access below the work area whenever installing or removing the fixture.

INSTALLATION

This section describes in general terms how to install the fixture, and to connect it to AC power,  

and to set up a data link (for multiple units only)

Installing the fixture

There are 2 ways of installing the Atmosphere panel.

• Floor mount: Place the Atmosphere panel on a flat surface, facing the

back side, with the power cable's up. Pull out the big metal support at 

the back of the unit, then pull out the small metal support underneath, 

fold it out and  place the big support in one of the cut-outs on the small 

support. Adjust the angle by repositioning the big support.

• Wall mount. Locate the 4 U-holes at the back of the unit. Mount the 4

wall mount adapters on a flat surface on the wall at the right spacing.  

Mount the Atmosphere on the 4 adapters, with the power cable's at 

the top side. 

AC power

You can power the Atmosphere panel with the supplied power cable.

• First you unscrew the end cap of the power cable. Then plug the male

AC connector of the Atmosphere panel in the female AC connector of the 

power cord. Tighten the connection ring on the connectors firmly.

• Multiple units can be wired in series by connecting the female

connector of the first unit to the male connector on the second, and 

so on. Be sure to mount the end cap on the last unit in a link. Never 

connect more than 32 units in series on one 16 amps breaker circuit 

to avoid peakloads due to high inrush currents. 

• Now you can plug the units in a grounded AC wall outlet.

U-hole

Master/Slave Switch

DMX in - DMX out

DATA LINKING MULTIPLE FIXTURES

You need to create a data link if you want to:

• Run multiple Atmosphere panels in a synchronous way using the optional remote control.

• Run multiple Atmosphere panels in a synchronous way in stand alone mode. 

• Control one or more fixtures by a DMX controller.

The Atmosphere panel can be data-linked by using the RJ45 input and output connectors at the backside of 

the unit.

To set up a data link you have to take the following steps

• Disconnect all the units from the AC supply. 

• Connect the RJ45 output of the first fixture to the RJ45 input of the next fixture by using the Cat5 cable 

   which is supplied with every unit.

• Continue connecting fixture's RJ45 output to next fixture's RJ45 input.

• A maximum of 32 units can be connected in this way.

• Never connect other DMX products with RJ45 connectors directly to an Atmosphere link, but use  

   dedicated adapters for these purposes! 