2

Please Read This Before Installing Or Operating Pump. 
This information is provided for 

SAFETY

 and to 

PREVENT 

EQUIPMENT PROBLEMS.

 To help recognize this information, 

observe the following symbols:

IMPORTANT!

 Warns about hazards that can result 

in personal injury orIndicates factors concerned with 
assembly, installation, operation, or maintenance which 
could result in damage to the machine or equipment if 
ignored.

CAUTION!

 Warns about hazards that 

can or will cause minor

 

personal injury or property damage if ignored. Used with symbols 
below.

WARNING!

  Warns about hazards that can or will cause serious 

personal injury, death, or major property damage if ignored. Used 
with symbols below.

Only quali

fi

 ed personnel should install, operate and repair 

pump. Any wiring of pumps should be performed by a quali

fi

 ed 

electrician.

WARNING !

 To reduce risk of electrical shock, pumps 

and control panels must be properly grounded in 
accordance with the National Electric Code (NEC) or 
the Canadian Electrical Code (CEC) and all applicable 
state, province, local codes and ordinances. Improper 
grounding voids warranty.

WARNING!

 To reduce risk of electrical shock, always 

disconnect the pump from the power source before 
handling or servicing. Lock out power and tag. 

WARNING!

 Operation against a closed 

discharge valve will cause premature bearing 
and seal failure on any pump, and on end 
suction and self priming pump the heat build 

may cause the generation of steam with resulting dangerous 
pressures. It is recommended that a high case temperature 
switch or pressure relief valve be installed on the pump body.

 

CAUTION !

 Pumps build up heat and pressure 

during operation-allow time for pumps to cool 
before handling or servicing.

 

WARNING !

 Do not pump hazardous materials 

(

fl

 ammable, caustic, etc.) unless the pump is speci

fi

 cally 

designed and designated to handle them.

 

 

WARNING !

 Do not wear loose clothing that may  

become entangled in moving parts.

  

WARNING !

 Keep clear of suction and discharge 

openings. 

DO NOT 

insert 

fi

 ngers in pump with power 

connected.  

Always wear eye protection when working on pumps. 

Make sure lifting handles are securely fastened each  
time before lifting. 

DO NOT

 operate pump without safety 

devices in place. Always replace safety devices that  
have been removed during service or repair. Secure the 
pump in its operating position so it can not tip over, fall  
or slide.

 

DO NOT

 exceed manufacturers recommendation for 

maximum performance, as this could cause the motor  
to overheat.

 

WARNING !

 To reduce risk of electrical shock, all  wiring 

and junction connections should be made per  the NEC 
or CEC and applicable state or province and  local 
codes. Requirements may vary depending on  usage 
and location.

  

WARNING!

 Products returned must be cleaned, 

sanitized, or decontaminated as necessary prior to 
shipment, to insure that employees will not be exposed 
to health hazards in handling said material. All Applicable 
Laws And Regulations Shall Apply.

 

Bronze/brass and bronze/brass 

fi

 tted pumps may 

contain lead levels higher than considered safe for 
potable water systems. Lead is known to cause cancer 
and birth defects or other reproductive harm. Various 
government agencies have determined that leaded 
copper alloys should not be used in  potable water 
applications. For non-leaded copper  alloy materials of 
construction, please contact factory.

 

Crane Pumps & Systems, Inc. is not responsible for 
losses, injury, or death resulting from a failure to observe 
these safety precautions, misuse or abuse of pumps or 
equipment.

SAFETY FIRST!

Hazardous fl uids can 
cause fi re or explo-
sions, burnes or death 
could result.

Extremely hot - Severe 
burnes can occur on contact.

Biohazard can cause 
serious personal injury.

Hazardous fl uids can Hazard-
ous pressure, eruptions or ex-
plosions could cause personal 
injury or property damage.

Rotating machinery
Amputation or severe 
laceration can result.

Hazardous voltage can 
shock, burn or cause death.

Other brand and product names are trademarks or registered trademarks of their respective holders.
Weinman® is a registered trademark of Crane Pumps & Systems, Inc.
 

8/2004, 

5/06, 

9/06 

         Alteration 

Rights 

Reserved

Summary of Contents for Weinman B Series

Page 1: ... product changes may occur As such Crane Pumps Systems reserves the right to change product without prior written notification 420 Third Street 83 West Drive Bramton Piqua Ohio 45356 Ontario Canada L6T 2J6 Phone 937 778 8947 Phone 905 457 6223 Fax 937 773 7157 Fax 905 457 2650 www cranepumps com Form No 119980 Rev E Series B VB VBM Type VB Vertical Pump Type VBM Vertical Frame Mounted Pump Type B ...

Page 2: ...discharge openings DO NOT insert fingers in pump with power connected Always wear eye protection when working on pumps Make sure lifting handles are securely fastened each time before lifting DO NOT operate pump without safety devices in place Always replace safety devices that have been removed during service or repair Secure the pump in its operating position so it can not tip over fall or slide...

Page 3: ...e Center check your Weinman representative or Crane Pumps Systems Inc Service Department in Piqua Ohio telephone 937 778 8947 or Crane Pumps Systems Canada Inc Bramton Ontario 905 457 6223 B INSTALLATION 1 FOUNDATION The pump foundation should be sufficiently substantial to form a level rigid support for the combined weight of the pump and driver and maintain alignment of the installed unit Founda...

Page 4: ...nment when the straight edge rests evenly on the coupling rim at all positions Allowance may be necessary for temperature changes and for coupling halves that are not of the same outside diameter Care must be taken to have the straight edge parallel to the axis of the shafts Correction for Angular and Parallel Misalignment is made by adjusting the shims under the driver After each change it is nec...

Page 5: ...on arrow on the pump casing Separate the coupling halves then start motor to see that it rotates in the direction required by the pump If it does not reverse any two main leads of the 3 phase wiring to the motor The coupling halves can be reconnected and the pump primed for starting C OPERATION 1 PRIMING CAUTION Before starting the pump the casing and suction line must be filled with liquid and ai...

Page 6: ... Heat exchanger is required for higher liquid temperatures 3 Pumps with seal chamber may be pressurized with Shell Alvania EPRO 71030 grease through suitable grease fitting if liquid lubrication is not available 2 IMPELLER ADJUSTMENT An outstanding feature of this pump is the axial adjustment of the impeller to compensate for eventual wear or corrosion Correct impeller adjustment will insure optim...

Page 7: ...rox 1 8 wide cut a groove axially along the sleeve to the shoulder of the shaft Grind the groove as deep as possible without damaging the shaft 2 After the groove has been cut insert a wedge tipped cold chisel into the groove at the impeller end of the sleeve Support shaft on a V block under the sleeve Tap chisel sharply with a hammer until crack occurs along the base of the groove 3 Pry groove ap...

Page 8: ...y light oil to the inside of the seal bellow and shaft sleeve 14 and slide the rotating seat assembly 89B onto the shaft sleeve 3 Place packing box cover 11 against frame 19 Be sure register is aligned and flange is fully seated in power frame and in proper position Then attach seal gland 251 to packing box cover with belts and nuts 209 210 Tighten securely Seal may be tested for leakage by applyi...

Page 9: ...ase 57 Elbow Suction 59 Cover Handhole 69 Lockwasher Bearing 73 Gasket Casing 203 Plate Name 204 Locknut Adjusting 206 Clip Split Gland 207 Fitting Grease 208 Plug Pipe 209 Bolt Machine 210 Nut Hex 211 Screw Set 212 Screw Cap 213 Screw Cap 214 Screw Drive Nameplate 215 Screw Cap 216 Plug Pipe 217 O ring ITEM DESCRITION 218 Screw Cap 220 O ring 221 Screw Cap 223 Cover Handhole 224 Screw Cap 226 Scr...

Page 10: ...e 40 Deflector 46 Key Coupling ITEM DESCRITION 51 Retainer Grease 59 Cover Handhole 69 Lockwasher Bearing 73 Gasket Casing 195 Screw Set 203 Plate Name 204 Locknut Adjusting 206 Clip Split Gland 207 Fitting Grease 208 Plug Pipe 209 Bolt Machine 210 Nut Hex 211 Screw Set 212 Screw Cap 213 Screw Cap 214 Screw Drive Nameplate 215 Screw Cap 216 Plug Pipe 217 O ring 218 Screw Cap 236 Plug Pipe ITEM DES...

Page 11: ...tboard 51 Retainer Grease 53 Base 57 Elbow Suction 59 Cover Handhole 69 Lockwasher Bearing 73 Gasket Casing 203 Plate Name 204 Locknut Adjusting 206 Clip Split Gland 207 Fitting Grease 208 Plug Pipe 209 Bolt Machine 210 Nut Hex 211 Screw Set 213 Screw Cap 214 Screw Drive Nameplate 215 Screw Cap 216 Plug Pipe 217 O ring 218 Screw Cap 220 O ring 221 Screw Cap 223 Cover Handhole ITEM DESCRITION 224 S...

Page 12: ...formance specifications must be in writing and such writing must be signed by our authorized representative Due to inaccuracies in field testing if a conflict arises between the results of field testing conducted by or for user and laboratory tests corrected for field performance the latter shall control RECOMMENDATIONS FOR SPECIAL APPLICATIONS OR THOSE RESULTING FROM SYSTEMS ANALYSES AND EVALUATI...

Page 13: ...nt To Insure That Employees Will Not Be Exposed To Health Hazards In Handling Said Material All Applicable Laws And Regulations Shall Apply IMPORTANT WARRANTY REGISTRATION Your product is covered by the enclosed Warranty To complete the Warranty Registration Form go to http www cranepumps com ProductRegistration If you have a claim under the provision of the warranty contact your local Crane Pumps...

Page 14: ...__ Type _________________________________ Number and size of short circuit device s ___________ Amp rating ___________________ Overload Type _____________ Size ______________ Amp rating ___________________ Do protection devices comply with pump and motor Amp rating YES___ NO___ Are all electrical and panel entry connections tight YES___ NO___ Is the interior of the panel dry YES___ NO___ Liquid le...

Page 15: ...s installed away from turbulence YES___ NO___ Is level control operating properly YES___ NO___ Is pump fully submerged during operation YES___ NO___ Follow up Corrective Action Required YES___ NO___ Additional Comments ____________________________________________________________________________ ____________________________________________________________________________ ___________________________...

Page 16: ...Notes ...

Reviews: