background image

ASSEMBLY 

 

ALWAYS use fresh cool water when operating the humidifier. 

 

1.  Turn Water Tank upside down and unscrew Water Tank Cap. 

 

2.  Fill Water Tank with cool water. DO NOT fill water all the way to the rim. 

 

DO NOT CARRY FULL WATER TANK BY HANDLE. 

 

ALWAYS HOLD FULL WATER TANK WITH TWO HANDS. 

 

DO NOT use hot water. Use cool tap water. 

 

DO NOT add any medication, essential oils, or salt. 

 

DO NOT pour water into Mist Outlet Channel. 

 

3.  Screw Water Tank Cap back onto Water Tank. Turn the Water Tank over and place on 

Water Base, making sure it fits perfectly. 

 

Note: Do not attempt to move the humidifier while Water Tank is placed on Water Base. 
Doing so may cause leakage of water and/or Water Base to overfill. 

 

4.  Plug the power cord into a wall socket and turn on the unit by using the Control Knob. 

 

 

5.  Use the Digital Control Panel to select the mode of your choice. The blue Power Indicator 

Light will illuminate. In a few seconds, mist will start emitting. 

 

6.  Use the Digital Control Panel to adjust the intensity of the mist output. 

 

SET THE CORRECT HUMIDITY OUTPUT: Adjust the Digital Control Panel so that the mist rises 
up to be absorbed by the room air. Do not set the mist output too high, as the mist cannot be 
absorbed by the air and may accumulate on the surfaces around the humidifier. 

 

 

7.  When the humidifier runs out of water, the humidifier will automatically shut off and the mist 

will stop. The Low Water Indicator Light will illuminate red. This safety feature uses a water 
level sensor to stop the Nebulizer once the water level sinks below the required level in the 
Humidifier Base. 

 

Note: The indicator light on the humidifier will remain on. The red light indicates that the 
humidifier is turned on and needs to be refilled. 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

 

Summary of Contents for EE-6905

Page 1: ...DIGITAL ULTRASONIC COOL WARM MIST HUMIDIFIER ITEM EE 6905 PLEASE READ AND SAVE ALL INSTRUCTIONS TO ENSURE THE SAFE AND EFFCTIVE USE OF THIS APPLIANCE ...

Page 2: ... of Contents P 1 Safety Instructions P 2 3 List of Main Parts Technical Specifications P 4 Humidifier Features P 5 Operation and Use P 5 Digital Control Panel Instructions P 6 Assembly P 7 Maintenance P 8 Trouble Shooting P 9 ...

Page 3: ...Customer Care P 10 Warranty P 11 ...

Page 4: ... avoid electric shock 7 Never operate the unit with a damaged cord or plug 8 Always place the unit on a smooth flat lint free non metallic waterproof and level surface and position unit away from direct sunlight Keep the cord away from heated surfaces and areas where it could be walked on or tripped over Unplug the unit when not in use and whenever you clean or move the unit 9 Do not add medicatio...

Page 5: ...rtop or tabletop where it can be pulled on by children or accidently tripped over ELECTRIC POWER If the electric circuit is overloaded by other appliances your humidifier and or appliances may not operate properly The humidifier should be operated on a separate electrical circuit from other operating appliances POLARIZED PLUG This humidifier has a polarized plug one blade is wider than the other A...

Page 6: ...5 Water Tank Cap 4 6 Water Base 7 Fan Vent 8 Nebulizer 3 9 Water Level Sensor Float 9 8 7 6 5 TECHNICAL SPECIFICATIONS Rating Voltage 120V Frequency 60Hz Power Cool Mist 30W Power Warm Mist 110W Water Tank Capacity 1 3 Gallon Run Time Per Tank Up to 24 hours Humidifying Capacity Up to 500 sq ft 46 m2 4 ...

Page 7: ...y much like the element in a high frequency stereo speaker to create mist An ultrasonic humidifier is whisper quiet and produces a fine mist into the room REMOTE CONTROL This Digital Humidifier includes a Remote Control that can be used to operate your device Simply pull the small plastic tab before use to activate OPERATION AND USE BEFORE EACH USE CHECK HUMIDIFIER PLACEMENT Place the Humidifier o...

Page 8: ...MIST CONTROL Press this button to change the mist output to Low Medium or High SET HUMIDITY LEVEL Press this button to set desired humidity level You can set the humidity level between 40 80 The recommended humidity level is between 40 60 COOL WARM MIST SELECTOR When humidifier is on cool mist will automatically start To select warm mist press this button and the warm mist setting will activate wi...

Page 9: ... using the Control Knob 5 Use the Digital Control Panel to select the mode of your choice The blue Power Indicator Light will illuminate In a few seconds mist will start emitting 6 Use the Digital Control Panel to adjust the intensity of the mist output SET THE CORRECT HUMIDITY OUTPUT Adjust the Digital Control Panel so that the mist rises up to be absorbed by the room air Do not set the mist outp...

Page 10: ... and empty water from tank base daily 2 Allow tank base to air dry 3 Leave cap off the tank until ready for next use WEEKLY MAINTENANCE 1 Turn off unplug from outlet and empty water from tank base 2 Fill the water tank halfway with warm water Add 2 Tablespoons of white vinegar Shake vigorously and let sit for 30 min Empty tank rinse with plain water TIP Use crushed ice or wire brush to help scrub ...

Page 11: ...eck for possible mineral deposits on the nebulizer Make sure that nothing blocks the mist output slot The digital display is on Check that the fan vent on bottom of humidifier is not but there is no mist blocked Empty the humidifier and rinse the water base with cool tap water and allow to dry for 30 minutes If this does not solve the problem please contact Crane Customer Care White dust appears a...

Reviews: