background image

 

GENERAL SAFETY INSTRUCTIONS 

WARNING! 

Read and understand all instructions. Failure to follow all instructions listed 

below may result in electric shock, fire or serious personal injury. The warnings, cautions, and 
instructions discussed in this instruction manual cannot cover all possible conditions and 
situations that may occur. It must be understood by the user that common sense and 
caution are a factor which cannot be built into this product, but must be supplied by the 
user. 

THIS HUMIDIFIER IS NOT A TOY! 

Do not let your child play with this humidifier. 

Serious injury and electrocution might 

be possible. This humidifier has to be operated by an adult only. Children should be 
supervised to ensure that they do not play with the humidifier. 

SAVE ALL INSTRUCTIONS! 

CAUTION: 

A short Power Supply Cord is provided to reduce the risk of personal injury 

resulting from becoming entangled in or tripping over a longer cord. Extension cords are 
available from local hardware stores and may be used if care is exercised in their use. If an 
extension cord is required, special care and caution is necessary. Also the extension cord 
must be (1) marked with an electrical rating of 125 V and at least 13 A., 1625 W., and (2) the 
cord must be arranged so that it will not drape over the countertop or tabletop where it can 
be pulled on by children or accidently tripped over. 

 

ELECTRIC POWER 

If the electric circuit is overloaded by other appliances, your humidifier and/or appliances 
may not operate properly. The humidifier should be operated on a separate electrical circuit 
from other operating appliances. 

 

POLARIZED PLUG 

This humidifier has a polarized plug (one blade is wider than the other). 
As a safety feature to reduce the risk of electrical shock, this plug is 
intended to fit in a polarized outlet only one way. If the plug does not fit 
fully in the outlet, reverse the plug. If it still does not fit, contact a 
qualified electrician. Do not attempt to defeat this safety feature. 

 

SAFETY WARNING 

Although your humidifier is easy to operate, for your safety, the below warnings must be 
followed: 

1.

 

Do not place the humidifier near a heat source. 

2.

 

Never leave the humidifier unattended while connected to the electrical outlet. 

3.

 

To avoid any accidents, never cover the Mist Lid when the humidifier is in operation. 

4.

 

Use the humidifier on a smooth, flat, lint-free, non-metallic, waterproof, and level surface 
away from water. 

5.

 

Do not unplug from the wall socket by pulling on the supply cord. 

6.

 

The humidifier must be unplugged: 

A.

 

Before either filling or emptying the Water Basin and/or Water Tank. 

B.

 

Before any cleaning or maintenance is performed. 

C.

 

After each use. 

D.

 

If it appears to be faulty. 

 

THIS PRODUCT IS INTENDED FOR HOUSEHOLD USE ONLY. 

Summary of Contents for EE-5951AD

Page 1: ... please contact Crane Customer Care Telephone no 8376 6466 Email sales crane philippines com PERSONAL Ultrasonic Cool Mist Humidifier and Aroma Diffuser FOR MODEL EE 5951AD PLEASE READ AND SAVE ALL INSTRUCTIONS TO ENSURE THE SAFE AND EFFECTIVE USE OF THIS HUMIDIFIER ...

Page 2: ...SAVE YOUR DATED PROOF OF PURCHASE You will need this in case of warranty ...

Page 3: ...and outside your home We know if cleaned and maintained properly our products last for years helping to reduce unnecessary use of resources and emissions making new products The Crane manual you are holding is from recycled materials with no added finishes or harmful dyes If the humidifier should no longer operate please be sure to dispose of the unit in an environmentally friendly way by taking i...

Page 4: ...at lint free non metallic waterproof and level surface and position unit away from direct sunlight Keep the cord away from heated surfaces and areas where it could be walked on or tripped over Unplug the unit when not in use and whenever you clean or move the unit 9 Do not cover any openings on the unit or insert objects into any openings 10 The unit should not be left unattended in a closed room ...

Page 5: ... over the countertop or tabletop where it can be pulled on by children or accidently tripped over ELECTRIC POWER If the electric circuit is overloaded by other appliances your humidifier and or appliances may not operate properly The humidifier should be operated on a separate electrical circuit from other operating appliances POLARIZED PLUG This humidifier has a polarized plug one blade is wider ...

Page 6: ... Humidifier Base 1 Power Icon 2 Light Icon 3 Power Indicator Light 4 Nebulizer 3 4 1 2 Fig 2 Bottom of Water Tank 5 Mist Outlet Channel 6 Water Fill Hole 7 Water Tank Cap 6 5 7 Fig 3 Other Parts 8 Mist Lid 9 Detachable Cord 9 8 ...

Page 7: ... on an elevated non metallic lint free waterproof level surface at least 2 feet above the floor DO NOT PLACE ON CARPET OR TOWEL The fan vent is located on the bottom of the humidifier base The fan vent MUST NOT be obstructed DO NOT PLACE ON WOOD SURFACE or near furniture that can be damaged by too much moisture CAUTION DO NOT attempt to operate the humidifier without water in the Water Tank DO NOT...

Page 8: ...umidifier Base and mist will begin emitting through the Mist Lid 1st Press Power Icon Humidifier on Low 2nd Press Power Icon Humidifier on High 3rd Press Power Icon Humidifier will turn off 1st Press Light Icon Humidifier light will cycle through colors 2nd Press Light Icon Humidifier light will stay on the last color 3rd Press Light Icon All Light options off Light options can function without th...

Page 9: ... until ready for next use WEEKLY MAINTENANCE 1 Turn off unplug from outlet and empty water from tank base 2 Fill the water tank halfway warm water and add 2 Tablespoons of white vinegar Shake vigorously and let sit for 20 30 minutes Empty tank and rinse with plain water 3 Fill base with warm water add 1 tablespoon of white vinegar and let sit for30 min Empty base wipe with a dry cloth TIP Clean th...

Page 10: ...tank Too much water in the base Empty base and let tank refill the base properly If there is a strange odor Clean the Water Tank with the water and vinegar solution and rinse with clean water Leave the empty Water Tank open for 12 hours without the Water Tank Cap attached in a cool place The mist output volume is low Clean the nebulizer as described in the weekly maintenance Too much water in the ...

Page 11: ...o normal wear and tear or commercial use In no event shall liability exceed the purchase price paid by the purchaser of the product Under no circumstances shall there be liability for any loss direct indirect or incidental or consequential damage arising out of or in connection with the use of this product This warranty is valid only in the 48 contiguous states plus the District of Columbia and ex...

Page 12: ...10 ...