Technical Support Group for assistance at 1-
800-688-9090.
It is recommended that the machine be located so
that the GFCI device will be accessible after the
machine is installed. After installation, visually
inspect the GFCI and power supply cord to be sure it
is not crushed, pinched, or stretched.
Protect the power supply cord during transportation
and use. Periodically inspect the power supply cord
for damage. If the cord or plug is worn or damaged,
it must be replaced with a power supply cord of the
same type, size and specification as originally
provided with the machine.
DO
NOT USE THE
VENDING MACHINE UNTIL THE WORN OR
DAMAGED CORD IS REPLACED.
FAILURE TO COMPLY WITH
THESE INSTRUCTIONS MAY
SUBJECT A SERVICE PERSON
OR USER TO THE RISK OF
INJURY OR ELECTRICAL
SHOCK WHICH CAN BE
SERIOUS OR FATAL.
PLACING THE VENDER ON LOCATION
!! CAUTION !!
DO NOT TRANSPORT THE
VENDER TO OR FROM THE
LOCATION LOADED WITH
PRODUCT OR DAMAGE TO THE
VENDER MAY RESULT.
The vender must be located on a solid, flat, and
level surface. Ensure the flooring can bear the
weight of a fully loaded vender (approx. 1134 lbs).
The vender must be positioned close enough to an
electrical outlet that an extension cord is not
required. If the machine will be subject to user
misuse or vandalism, it is recommended that the
vender be secured to the floor or wall as described
in Dixie-Narco Technical Bulletin 344. Call the Dixie-
Narco Technical Service Department or your Dixie-
Narco Representative for assistance.
LEVEL THE VENDER
When the vender is level, the door can be opened to
any position and it will not move by itself. Open the
door to several different positions before deciding
the vender is level. A carpenter’s level will help
verify the machine is level.
Make sure that all leveling legs are in contact with
the floor. If you cannot level the vender in its current
location, select another location. DO NOT place any
objects under the machine.
DANGER
THE VENDER MUST BE
PROPERLY LOCATED AND
LEVELED. IF THE MACHINE WILL
BE SUBJECT TO USER MISUSE
OR VANDALISM IT IS
RECOMMENDED THAT THE
VENDER BE SECURED TO THE
FLOOR OR WALL AS DESCRIBED
IN DIXIE-NARCO TECHNICAL
BULLETIN 344 TO MINIMIZE THE
RISK OF INJURY OR DEATH
FROM TIPPING. CALL THE DIXIE-
NARCO TECHNICAL SERVICE
DEPARTMENT OR YOUR DIXIE-
NARCO REPRESENTATIVE FOR
ASSISTANCE.
SPACE THE VENDER
Do not block the rear of the vender. Keep the vender 4
inches (10 cm) from the wall to ensure adequate airflow to
the condenser and compressor. At the front of the vender,
make sure that nothing obstructs the air intake at the
bottom of the main door. At the rear of the vender, make
sure nothing obstructs the air exhaust at the bottom of the
cabinet.
WARNING
TO AVOID THE POSSIBILITY OF A
FIRE HAZARD, DO NOT STORE
ANYTHING OR ALLOW DEBRIS OF
ANY KIND TO ACCUMULATE IN
THE BOTTOM OF THE DOOR, IN
AND AROUND THE
REFRIGERATION
COMPARTMENT, THE CABINET,
OR IN FRONT OF THE
EVAPORATOR AND CONDENSER
COILS.
COIN CHANGERS & OTHER
ACCESSORIES
The vender must have an MDB coin changer
installed and can have an MDB bill acceptor
installed. If the MDB coin changer and other MDB
accessories are not factory installed, refer to the
instructions received from the manufacturer of the
MDB coin changer and other MDB accessories for
proper set-up and installation.
The vender will support the following MDB coin
changers:
Multi-Drop Coin Mech (Domestic)
Summary of Contents for Dixie-Narco 504 P Series
Page 32: ...TROUBLESHOOTING FLOWCHARTS P SERIES Page 32 of 99 ALL BILLS ARE REJECTED ...
Page 33: ...TROUBLESHOOTING FLOWCHARTS P SERIES Page 33 of 99 INCORRECT CHANGE DISPENSED ...
Page 36: ...TROUBLESHOOTING FLOWCHARTS P SERIES Page 36 of 99 COMPRESSOR WILL NOT START ...
Page 39: ...TROUBLESHOOTING FLOWCHARTS P SERIES Page 39 of 99 LIGHTS ARE NOT ON ...
Page 41: ...TROUBLESHOOTING FLOWCHARTS P SERIES Page 41 of 99 SOLD OUT ...
Page 43: ...TROUBLESHOOTING FLOWCHARTS P SERIES Page 43 of 99 CAN T READ THE DISPLAY ...
Page 44: ...WIRING DIAGRAMS AND SCHEMATICS P SERIES Page 44 of 99 10 SELECT 10 COLUMN ...
Page 47: ...PARTS LIST P SERIES Page 47 of 99 MAIN DOOR EXTERIOR Dr Pepper V4 3 10 18 11 13 14 16 9 2 8 1 ...
Page 49: ...PARTS LIST P SERIES Page 49 of 99 MAIN DOOR EXTERIOR Chameleon 11 13 8 14 16 10 2 18 9 3 1 ...
Page 56: ...PARTS LIST P SERIES Page 56 of 99 MAIN DOOR INTERIOR A Dual Display 10 8 9 17 1 3 2 18 ...
Page 57: ...PARTS LIST P SERIES Page 57 of 99 MAIN DOOR INTERIOR A DP SL5 1 2 7 9 8 19 18 6 10 ...
Page 58: ...PARTS LIST P SERIES Page 58 of 99 MAIN DOOR INTERIOR A Chameleon 11 18 17 4 1 9 8 3 10 ...
Page 77: ...PARTS LIST P SERIES Page 77 of 99 ELECTRONIC COMPONENTS 4 6 7 2 2 1 SL5 2 A 2 B ...
Page 79: ...PARTS LIST P SERIES Page 79 of 99 INNER DOOR ASSEMBLY 9 8 2 7 5 11 10 4 5 6 16 1 17 ...
Page 82: ...PARTS LIST P SERIES Page 82 of 99 HARNESSING Single Board Controller 6 7 5 4 3 2 ...
Page 84: ...PARTS LIST P SERIES Page 84 of 99 POWER DISTRIBUTION 11 12 10 5 7 5 4 3 8 2 1 9 ...
Page 93: ...PARTS LIST P SERIES Page 93 of 99 RERFRIGERATION SYSTEM 5 6 7 13 12 15 11 10 2 4 3 1 8 14 ...
Page 95: ...PARTS LIST P SERIES Page 95 of 99 SCREWS NUTS ...
Page 97: ...PARTS LIST P SERIES Page 97 of 99 WASHERS BOLTS MISC HARDWARE ...