background image

  

EXTERNAL COMMUNICATION INTERFACE FEATURES: 
 

MDB INTERFACE 

 

Country Code = 1840h 

 

Decimal Place = 2 

 

Scaling Factor = 100 

 
DIP SWITCHES SETTING: 

 

Switch 

ON state 

OFF state 

Default 

Setting 

SW1 

Reserved 

Reserved 

ON 

SW2 

Reserved 

Reserved 

ON 

SW3 

Reserved 

Reserved 

ON 

SW4 

Reserved 

Reserved 

ON 

SW5 

Reserved 

Reserved 

ON 

SW6 

Reserved 

Reserved 

ON 

SW7 

Reserved 

Reserved 

OFF 

SW8 

Service Mode 

To work with a “Vending 

Machine Controller” 

OFF 

 
RECYCLING CASSETTE CONTROLS: 

 

The Recycling Cassette controls are shown on the drawing below. 

 
RECYCLING CASSETTE DIP SWITCHES SETTING:* 

Switch 

ON state 

OFF state 

Default Setting 

SW1 

Reserved 

Reserved 

OFF 

SW2 

Cassette setup mode 

Normal operation 

OFF 

*Recycling cassette is always assigned to 1$.  
 
 

RECYCLING CASSETTE INDICATOR: 

 

Recycling cassette indicator shows number of the bills inside of the recycling cassette. In 
case of an error it will start flashing showing consequently number of bills and one of the 
following error codes: 

E0h    

– there was a hardware error detected 

E1h    – 

no communication with Coin Changer. In this case device will emulate Coin 

Changer with 1 tube (1$ US).This feature not active in Recycler mode. 

E2h    

– Recycling Cassette operations are disabled if jam occurs (1 red flash is blinked 

on bezel every 4 sec). 
 
FEED/UNLOAD BUTTONS: 

 

The feed button is used for setting a loading mode. This mode makes the entered bills of 
a selected denomination to be loaded into the recycling cassette. To cancel a loading 
mode, the feed button must be pressed again. If the bills do not enter within 20 seconds, 
the loading mode will be canceled automatically. 
By pressing the unload button one bill will be dispensed from the recycling cassette 
through the entry channel. If the feed and unload buttons are pressed simultaneously then 
all bills will be unloaded from the recycling cassette into the drop cassette.  
If  the feed or unload button is pressed and held for  4 sec. then the unloading or 
dispensing mode is interrupted. 
 
RECYCLING CASSETTE SETUP MODE: 

 

Recycling Cassette setup mode allows user to adjust recycling cassette feed and unload 
levels (maximal number of bills accepted into the cassette and number of bills to be left 
in the cassette during unload operation correspondingly) without need of special 
equipment. In order to enter the setup mode set SW2 to ON. The cassette indicator will 
start blinking “FL”(Fill level) or “UL”(unload level) and the set level consequently. 
Press FEED button to increase level and UNLOAD to decrease it. In order to switch 
between feed and unload settings press two buttons simultaneously. 
When setting is done set SW2 to OFF. Unit will switch to normal operation. No power 
cycling is necessary. 

 

CURRENZA CONFIGURATION CARDS: 

 

 

Fill in configuration card blocks as needed, use black pen or marker. 

 

Place DIP switches 1 through 6 in ON, switches 7 and 8 in OFF and  

power-up recycler. 

 

Remove the drop cassette. 

 

Place configuration card into bezel, all the way in. 

 

Mount drop cassette, unit will take the card right in and give a blinking pattern. 

 

4 long BLUE flashes means Ok. 

 

4 long RED flashes means wrong Config.Card 

 

“N” short RED flashes means error in row “N” of Configuration Cards.  

Two red short blinks

 will be showed in case of rejecting of banknote because it was 

disabled by VMC. 

DIP Switches

Unload button

Feed button

LCD display