3.1. TRANSPORTATION AND STORAGE

TRANSPORT / STORAGE

To avoid PV module damage: 

Store PV module in dry premises. The package is not atmosphere influence resistible! 

Transport the module in its original package until its instalation.  

Use vacuum cupping glass for modules' movement and transportation or hold the module by 
the edges.  Carry the module in vertical position when transporting over long distances. 

Do not pick and do not move the module while using the cables or the junction box area in 
under any circumstances!

Do not pile-up modules one over another!

Do not let the module to recline on its edges, without protecting it.

4. INSTALATION POSITIONING

The module is tested for safety operation in temperate climate. 

Allowed   temperatures   for   the   module   are   between   -40

О

C   and   +85

О

C.  Check   if   there   is 

adequate ventilation under the module, so the maximal temperature exceeding to be avoided.

Observe the requirements for functional grounding in dependence of modules positioning (see 
chapter 5.4 “Grounding”).

Do not expose the module to the chemicals impact

Do not deep the module in water. Th junction box is resistible only to water drops.

Do not position the module neear to flamable gases or vapours (eg. gas containers) or near to 
open fire or flamable materials. 

AVOIDING THE SHADING 

The optimal solar radiation leads to maximal electric production. This for, position the module in a way 
that the photovoltaic cells to be oriented toward the sun. 
Avoid module shading, as this will cause negative effect to its performance. It is believed that a module 
is fully without shading, when there is no shadow over it though the year (eg. shadow from: buildings,  
chimneys, trees). Even partial modules shading (eg. overhead cables, polution, snow) must be avoided  
(see also chapter 7 “Cleaning and maintenance”).
Also carefuly revise the modules' orienatation specification and the inclination degree (see chapter 5.1 
“Mechanical assemblying”).

5. ASSEMBLY AND INSTALATION 

SAFETY INSTRUCTIONS

WARNING! Damaged modules' components can create risk of fire!

Instal only reliable photovoltaic module.

Before the instalation, make sure that junction box, cable and connectors are not damaged. 

Do not open junction box in any circumstances.

Allways keep the photovoltaic module in dry premises. The package is not climate influence 
resistible!

The modules' voltage is higher with lower temperatures and/or when there is higher radiation 
than the Standard Test Conditions (25

O

C cells temperature, 1000W/m

2

, AM 1,5). This must be 

taken into account when you connect several modules, so that the total voltage of the modules 
strings must not exceed 1000 VDC (in agreement with IEC 61215, Edition 1/61730, Edition 2) or 
600 VDC (in agreement with UL1703).

Please   comply   with   the   requirements   for   functional   grounding   in   dependence   of   modules' 
positioning (see Chapter 5.4, “Grounding”)

5

Summary of Contents for CPV36M Series

Page 1: ...e and operation with monocristal photovoltaic modules CPV36Mxx and CPV60Mxx Users manual for monocristal photovoltaic modules Crane Ltd Bulgaria 4004 Plovdiv 26 Komatevsko shose Str phone 35932657578 fax 35932657580 e mail office crane bg com www crane bg com ...

Page 2: ... Transportation and storage Page 5 4 Instalation positioning Page 5 5 Assembly and instalation Page 6 5 1 Mechanical assemblying Page 6 5 2 Electric scheme Page 7 5 3 Grounding Page 8 5 4 Electric instalation Page 8 6 Cleaning and maintenance Page 9 7 Problems in operation Page 10 8 Contacts Page 10 2 ...

Page 3: ...during the time of delivery and instalation of photovoltaic module CPV36M140 and CPV60M240 Please keep this instruction during whole service life of PV module Please read very carefully chapters 6 cleaning and maintenance and 7 problems in operation The instalation and maintenance of your photovoltaic module must be performed only by well trained personal who can perform the technical procedure de...

Page 4: ...ver the photovoltaic module with opaque material during the whole assemblying period Only by this way it will be surely de energized It is nesessary to comply with the regulations and the safety instructions when instaling the electric devices and systems In case of module or phase voltage over 120V the additional low voltage remains Provide the necessary protection and safety measures Do not put ...

Page 5: ...eads to maximal electric production This for position the module in a way that the photovoltaic cells to be oriented toward the sun Avoid module shading as this will cause negative effect to its performance It is believed that a module is fully without shading when there is no shadow over it though the year eg shadow from buildings chimneys trees Even partial modules shading eg overhead cables pol...

Page 6: ...instaled in horizontal or in vertical position During modules instalation the junction box must be at their upper side and the cables to drop down The modul must be installed in way that the rain water and melting snow to drain freely After the instalation the draining holes must be opened to be avoided the water retention and puddles formation so the risk of damages caused of freezing to be broug...

Page 7: ... though standard test conditions This for it is necessary the safety factor of 1 25 to be included for Determination of the values for components voltage measuring Voc Determinating of the values for wires current measuring Isc Evaluation of the control systems connected to the photovoltaic modules output Alternatively the valid national regulations for electrical systems instaling should be imple...

Page 8: ...onnectors from the same type and manufacturer and compatible connectors for the invertors connection Check if all electric components are in right dry and safety condition Tat is how you avoid electric shortcuts or dangerous contact voltage due to deffect or damaged cables Allways avoid mechanical presure on the connecting cables Ensure tight connection between individual connectors especially to ...

Page 9: ...Do not use abrasive cleaning materials or surface active agents eg soap Do not scrap out the contaminations This might damage the modules surface Compulsory snow and ice removement from modules surface can lead to mechanical damages MAINTENANCE Modules must be inspected yearly by skilled specialist about the following Examination of the fixing and not corroded systems components Examination of the...

Reviews: