background image

Notes

Summary of Contents for BARNES SP33 Series

Page 1: ...roduct improvement program product changes may occur As such Crane Pumps Systems reserves the right to change product without prior written notification 420 Third Street 83 West Drive Bramton Piqua Ohio 45356 Ontario Canada L6T 2J6 Phone 937 778 8947 Phone 905 457 6223 Fax 937 773 7157 Fax 905 457 2650 www cranepumps com Form No 112251 Rev P Series SP33 33 HP 3450 RPM 60 Hz 2 HP 2850 RPM 50 Hz ...

Page 2: ...ake sure lifting handles are securely fastened each time before lifting DO NOT operate pump without safety devices in place Always replace safety devices that have been removed during service or repair Secure the pump in its operating position so it can not tip over fall or slide DO NOT exceed manufacturers recommendation for maximum performance as this could cause the motor to overheat DO NOT rem...

Page 3: ...ARING Design Single Row Ball Oil Lubricated Load Radial LOWER BEARING Design Single Row Ball Oil Lubricated Load Radial Thrust MOTOR Design Oil Filled Insulation Class B SINGLE PHASE Permanent Split Capacitor PSC ELECTRICAL 120 Volt 1 Phase 60 Hz 5 8FLA 50 Hz 5 0FLA WINDING RESISTANCE Main 4 3 Ω Start 12 7Ω LEVEL CONTROLS SP33 None SP33A Wide Angle Mechanical 10 Ft 3m Cord or 20 Ft 6m Cord SP33V V...

Page 4: ...arnes representative or Crane Pumps Systems Inc Service Department in Piqua Ohio telephone 937 778 8947 or Crane Pumps Systems Canada Inc Bramton Ontario 905 457 6223 SECTION C INSTALLATION C 1 Location These pumping units are self contained and are recom mended for use in a sump or basin This pump is designed to pump rain water or light effluent nonexplosive and noncorrosive liquids and shall NOT ...

Page 5: ...t the pump off if the windings become too hot or the load current passing through them becomes too high It will then automatically reset and start the pump up after the motor cools to a safe temperature In the event of an overload the source of this condition should be determined and rectified immediately DO NOT LET THE PUMP CYCLE OR RUN IF AN OVERLOAD CONDITION OCCURS SECTION D SERVICE AND REPAIR ...

Page 6: ...ge and pump design This number is used for ordering and obtain ing information E 3 Date Code The Date Code consists of two numbers which are punched holes in the nameplate This specifies the month and year which indicates the date the unit was built SERVICE PARTS AVAILABLE LEVEL CONTROLS 113647 Vertical Float 10 Ft Piggy Back 113647A Vertical Float 20 Ft Piggy Back 106929 Mech Wide Angle 10 Ft Pigg...

Page 7: ...heck cutter for freedom of operation security and condition Clean cutter and inlet of any obstruction 9 Loosen union slightly to allow trapped air to escape Verify that turn off level of switch is set so that the suction is always flooded Clean vent hole 10 Remove examine for damage Replace pump stator if required 11 Repair fixtures as required to eliminate leakage 12 Check pump temperature limits fl...

Page 8: ...rformance specifications must be in writing and such writing must be signed by our authorized representative Due to inaccuracies in field testing if a conflict arises between the results of field testing conducted by or for user and laboratory tests corrected for field performance the latter shall control RECOMMENDATIONS FOR SPECIAL APPLICATIONS OR THOSE RESULTING FROM SYSTEMS ANALYSES AND EVALUATIONS ...

Page 9: ...nt To Insure That Employees Will Not Be Exposed To Health Hazards In Handling Said Material All Applicable Laws And Regulations Shall Apply IMPORTANT WARRANTY REGISTRATION Your product is covered by the enclosed Warranty To complete the Warranty Registration Form go to http www cranepumps com ProductRegistration If you have a claim under the provision of the warranty contact your local Crane Pumps...

Page 10: ...Notes ...

Reviews: