12
ELECTRICAL CORD CONNECTIONS
CORD CABLES
- The cord assembly mounted to the switch must
NOT
be modi
fi
ed in any way except
for shortening to a speci
fi
c application. Any modi
fi
cations to the switch cord will void the warranty.
OVER-TEMPERATURE PROTECTION
- The type of in-line over-temperature protector used in this level
control is referred to as an inherent overheating protector and operates on the affect of temperature rise.
This means that the over-temperature protector will trip out and shut the pump off if the switch becomes
too hot. It will then automatically reset after the switch cools to a safe temperature. In the event of an
over-temperature, the source of this condition should be determined and recti
fi
ed immediately.
DO NOT LET THE PUMP CYCLE OR RUN IF AN OVER-TEMPERATURE CONDITION OCCURS!
CORD CONNECTION -
Insert female end of cord plug into housing bore aligning alignment mark with
detent in terminal block, See Figure Below.
Tighten bolts until the corners of the compression
fl
ange are drawn down to the top of the level control.
DO NOT OVER TORQUE.