Please Read This Before Installing Or Operating Pump. 
This information is provided for 

SAFETY

 and to 

PREVENT 

EQUIPMENT PROBLEMS.

 To help recognize this information, 

observe the following symbols:

IMPORTANT!

 Warns about hazards that can result 

in personal injury orIndicates factors concerned with 
assembly, installation, operation, or maintenance which 
could result in damage to the machine or equipment if 
ignored.

CAUTION!

 Warns about hazards that 

can or will cause minor

 

personal injury or property damage if ignored. Used with symbols 
below.

WARNING!

  Warns about hazards that can or will cause serious 

personal injury, death, or major property damage if ignored. Used 
with symbols below.

Only qualifi 

ed personnel should install, operate and repair 

pump. Any wiring of pumps should be performed by a qualifi ed 
electrician.

WARNING !

 To reduce risk of electrical shock, pumps 

and control panels must be properly grounded in 
accordance with the National Electric Code (NEC) or 
the Canadian Electrical Code (CEC) and all applicable 
state, province, local codes and ordinances. Improper 
grounding voids warranty.

WARNING!

 To reduce risk of electrical shock, always 

disconnect the pump from the power source before 
handling or servicing. Lock out power and tag. 

WARNING!

 Operation against a closed 

discharge valve will cause premature bearing 
and seal failure on any pump, and on end 
suction and self priming pump the heat build 

may cause the generation of steam with resulting dangerous 
pressures. It is recommended that a high case temperature 
switch or pressure relief valve be installed on the pump body.

CAUTION !

 Never operate a pump with a plug-in  type 

power cord without a ground fault  circuit interrupter.

 

CAUTION !

 Pumps build up heat and pressure 

during operation-allow time for pumps to cool 
before handling or servicing.

 

WARNING !

 Do not pump hazardous materials 

(fl ammable, caustic, etc.) unless the pump is specifi cally 
designed and designated to handle them.

 

CAUTION !

 

Do not

 block or restrict discharge hose, as 

discharge hose may whip under pressure.

 

WARNING !

 Do not wear loose clothing that may  

become entangled in moving parts.

  

WARNING !

 Keep clear of suction and discharge 

openings. 

DO NOT 

insert fi ngers in pump with power 

connected.  

Always wear eye protection when working on pumps. 

Make sure lifting handles are securely fastened each 

 

time before lifting. 

DO NOT

 operate pump without safety 

devices in place. Always replace safety devices that 

 

have been removed during service or repair. Secure the 
pump in its operating position so it can not tip over, fall  
or slide.

 

DO NOT

 exceed manufacturers recommendation for 

maximum performance, as this could cause the motor  
to overheat.

 

DO NOT

 remove cord and strain relief. 

DO NOT

 connect 

conduit to pump.

 

WARNING !

 Cable should be protected at all times to  

avoid punctures, cut, bruises and abrasions. Inspect 
frequently. Never handle connected power cords with 

 

wet hands.

 

WARNING !

 To reduce risk of electrical shock, all  wiring 

and junction connections should be made per  the NEC 
or CEC and applicable state or province and  local 
codes. Requirements may vary depending on  usage 
and location.

 

WARNING!

 Submersible Pumps are not approved for 

 

use in swimming pools, recreational water installations 
decorative fountains or any installation where human 
contact with the pumped fl uid is common.

  

WARNING!

 Products returned must be cleaned, 

sanitized, or decontaminated as necessary prior to 
shipment, to insure that employees will not be exposed 
to health hazards in handling said material. All Applicable 
Laws And Regulations Shall Apply.

 

Bronze/brass and bronze/brass fi tted pumps may 
contain lead levels higher than considered safe for 
potable water systems. Lead is known to cause cancer 
and birth defects or other reproductive harm. Various 
government agencies have determined that leaded 
copper alloys should not be used in  potable water 
applications. For non-leaded copper  alloy materials of 
construction, please contact factory.

 

Crane Pumps & Systems, Inc. is not responsible for 
losses, injury, or death resulting from a failure to observe 
these safety precautions, misuse or abuse of pumps or 
equipment.

SAFETY FIRST!

Hazardous fl uids can 
cause fi re or explo-
sions, burnes or death 
could result.

Extremely hot - Severe 
burnes can occur on contact.

Biohazard can cause 
serious personal injury.

Hazardous fl uids can Hazard-
ous pressure, eruptions or ex-
plosions could cause personal 
injury or property damage.

Rotating machinery
Amputation or severe 
laceration can result.

Hazardous voltage can 
shock, burn or cause death.

Other brand and product names are trademarks or registered trademarks of their respective holders.
® Barnes is a registered trademark of Crane Pumps & Systems, Inc.
1998, 

2002, 

1/2006, 

4/06, 

9/06        Alteration 

Rights 

Reserved

Summary of Contents for BARNES BAF-E3

Page 1: ...ems Inc constant product improvement program product changes may occur As such Crane Pumps Systems reserves the right to change product without prior written notification 420 Third Street 83 West Drive Bramton Piqua Ohio 45356 Ontario Canada L6T 2J6 Phone 937 778 8947 Phone 905 457 6223 Fax 937 773 7157 Fax 905 457 2650 www cranepumps com Form No 105750 Rev F Series BAF E3 P N N014 00035 Manual Ind...

Page 2: ...ake sure lifting handles are securely fastened each time before lifting DO NOT operate pump without safety devices in place Always replace safety devices that have been removed during service or repair Secure the pump in its operating position so it can not tip over fall or slide DO NOT exceed manufacturers recommendation for maximum performance as this could cause the motor to overheat DO NOT rem...

Page 3: ...nbolt the pump flanges STATIONARY ELBOW Cast iron ASTM A48 Class 30 MOVABLE FITTING Bronze 81 3 7 9 GUIDE RAIL CAP Bracket 304 stainless steel Plugs Cast iron ASTM A48 Class 30 HARDWARE 300 Series stainless steel O RINGS Buna N 70 5 Duro GASKETS Rubber PAINT Air Dry Enamel OPTIONAL INTERMEDIATE SUPPORT Bracket 304 stainless steel Plugs Cast iron ASTM A48 Class 30 Hardware 300 Series stainless steel...

Page 4: ...nc Bramton Ontario 905 457 6223 SECTION C INSTALLATION C 1 Location The Non Sparking Break A Way Fitting Model BAF E3 when used in conjunction with Barnes Pumps 3 Explosion Proof Submersible Sewage Pumps Series 3XSE is recommended for operation in a non hazardous or Class 1 Group D Division 1 hazardous location wet well basin or lift station C 2 Design Layout Models BAF E3 assembled with pumps lis...

Page 5: ...5 FIGURE 4 Duplex Installation Standard FIGURE 5 Duplex Installation Optional FIGURE 3 Simplex Installation ...

Page 6: ...o 10º C 8 Installation Descent Speed When lowering pump into wet well on the guide rails do not exceed a descent speed of 3 2 inches per second or 16 feet per minute SECTION D MAINTENANCE AND REPAIR D 1 Maintenance Whenever the pump is lifted for inspection it is recommended any foreign material be flushed from moveable fitting guide plugs and stationary base elbow face before replacement in wet wel...

Page 7: ...7 FIGURE 6 ...

Page 8: ...8 FIGURE 7 ...

Page 9: ... 3 3 118 2 Flat Hd Screw 1 4 20 x 1 00 Lg Silicon Bronze 7 1 014 00153 201 O Ring Plate Bronze 8 1 625 00143 Tetra Seal 9 1 014 00151 101 Angle Adapter 10 1 625 01077 Ring Gasket 11 4 1 93 6 Hex Hd Screw 5 8 11 x 1 75 Lg Zp 12 3 1 93 6 Hex Hd Screw 5 8 11 x 1 75 Lg Zp 13 2 625 02549 Spring Washer 250 1250 Stainless 14 7 20 24 6 Lock Washer 5 8 Zp 15 1 014 00060 101 Slide Assy 16 2 014 00059 201 Bu...

Page 10: ...OSE RESULTING FROM SYSTEMS ANALYSES AND EVALUATIONS WE CONDUCT WILL BE BASED ON OUR BEST AVAILABLE EXPERIENCE AND PUBLISHED INDUSTRY INFORMATION SUCH RECOMMENDATIONS DO NOT CONSTITUTE A WARRANTY OF SATISFACTORY PERFORMANCE AND NO SUCH WARRANTY IS GIVEN This warranty shall not apply when damage is caused by a improper installation b improper voltage c lightning d excessive sand or other abrasive ma...

Page 11: ...E CITY STATE ZIP MODEL NO SERIAL NO PART NO BRAND IMPORTANT WARRANTY REGISTRATION Your product is covered by the enclosed Warranty Complete the Warranty Registration Form and return to Crane Pumps Systems Inc Warranty Service Group If you have a claim under the provision of the warranty contact your local Crane Pumps Systems Inc Distributor ...

Page 12: ...CRANE PUMPS SYSTEMS INC WARRANTY SERVICE GROUP 420 THIRD STREET PIQUA OHIO 45356 U S A FOLD HERE AND TAPE DO NOT STAPLE PLACE STAMP HERE ...

Reviews: