Please Read This Before Installing Or Operating Pump. This
information is provided for 

SAFETY and to PREVENT EQUIPMENT

PROBLEMS.

 To help recognize this information, observe the

following symbols:

IMPORTANT!

 Warns about hazards that can result in

personal injury or Indicates factors concerned with
assembly, installation, operation, or maintenance which

could result in damage to the machine or equipment if ignored.

CAUTION !

   Warns about hazards that 

can or will cause minor

personal injury or property damage if ignored. Used with symbols
below.

WARNING ! 

  Warns about hazards that 

can or will cause serious

personal injury, death, or major property damage if ignored. Used
with symbols below.

 

Only qualified personnel should install, operate and repair pump. Any
wiring of pumps should be performed by a qualified electrician.

   WARNING !

 To reduce risk of electrical shock, pumps and

  control panels must be properly grounded in accordance
  with the National Electric Code (NEC) or the Canadian
  Electrical Code (CEC) and all applicable state, province,
  local codes and ordinances. Improper grounding voids
  warranty

  

WARNING !

 To reduce risk of electrical shock, always

  disconnect the pump from the power source before
  handling or servicing. Lock out power and tag.

 

WARNING !

 Operation aga inst a closed

discharge valve will cause premature bearing
and seal failure on any pump, and on end suction

and self priming pump the heat build may cause the generation of
steam with resulting dangerous pressures. It is recommended that
a high case temperature switch or pressure relief valve be installed
on the pump body.

  

CAUTION !

  Never operate a pump with a plug-in 

  type power cord without a ground fault 
  circuit interrupter.

  

CAUTION ! 

Pumps build up heat and pressure

  during operation-allow time for pumps to cool
  before handling or servicing.

  

WARNING !

  Do not pump hazardous materials

  (flammable, caustic, etc.) unless the pump is
  specifically designed and designated to handle them.

  

CAUTION !

 Do not block or restrict discharge hose,

  as discharge hose may whip under pressure.

  

WARNING !

 Do not wear loose clothing that may 

  become entangled in moving parts.

 

  WARNING ! 

Keep clear of suction and discharge

  openings. DO NOT insert fingers in pump with
  power connected.

 

 

  Always wear eye protection when working on pumps.

  Make sure lifting handles are securely fastened each 
  time before lifting. 

DO NOT

 operate pump without safety

  devices in place. Always replace safety devices that 
  have been removed during service or repair. Secure the
  pump in its operating position so it can not tip over, fall 
  or slide.

  DO NOT

 exceed manufacturers recommendation for

  maximum performance, as this could cause the motor 
  to overheat.

  

DO NOT

 remove cord and strain relief. 

DO NOT 

connect

  conduit to pump.

  

WARNING !

 Cable should be protected at all times to 

  avoid punctures, cut, bruises and abrasions. Inspect
  frequently. Never handle connected power cords with 
  wet hands.

  

WARNING !

  To reduce risk of electrical shock, all 

  wiring and junction connections should be made per 
  the NEC or CEC and applicable state or province and 
  local codes. Requirements may vary depending on 
  usage and location.

  

WARNING !

  Submersible Pumps are not approved for 

  use in swimming pools, recreational water installations
  decorative fountains or any installation where human
  contact with the pumped fluid is common.

  

 WARNING !

  Products returned must be cleaned,

   sanitized, or decontaminated as necessary prior to
   shipment, to insure that employees will not be exposed to
   health hazards in handling said material. All Applicable
   Laws And Regulations Shall Apply.

   Bronze/brass and bronze/brass fitted pumps may contain
   lead levels higher than considered safe for potable water
   systems. Various government agencies have determined
   that leaded copper alloys should not be used in 
   potable water applications. For non-leaded copper 
   alloy materials of construction, please contact factory.

  BARNES® Pumps, Inc.  is not responsible for losses, injury,
 or death resulting from a failure to observe these safety
  precautions, misuse or abuse of pumps or equipment.

SAFETY  FIRST!

Hazardous fluids

 can

cause fire or explosions,
burns or death could result.

Extremely hot

 -

Severe burns can
occur on contact.

Eye protection
required

Hazardous voltage

 can

shock, burn or cause
death.

Toxic Fumes

 -

Breathing can cause 
nausea, fainting or death.

Hazardous pressure

Eruptions or explosions
could cause personal 
injury or property damage

Biohazard

 can cause 

serious personal injury.

Rotating machinery 

 Amputation or severe 
 laceration can result.

3

Manual Index

HOME

MENU

Summary of Contents for Barnes 2ADG8

Page 1: ...roduct changes may occur As such Crane Pumps Systems Inc reserves the right to change product without prior written notification Models 2ADG8 2CDG8 3ADG8 3CDG8 BARNES 420 Third Street P O Box 603 83 West Drive Brampton Piqua Ohio 45356 0603 Ontario Canada L6T 2J6 Phone 937 778 8947 Phone 905 457 6223 Fax 937 773 7157 Fax 905 457 2650 www cranepumps com PUMPS SYSTEMS A Crane Co Company Manual Index...

Page 2: ... LIST ADG8 13 14 RETURNED GOODS POLICY 15 WARRANTY WARRANTY INFORMATION REGISTRATION Other brand and product names are trademarks or registered trademarks of their respective holders Barnes is a registered trademark of Barnes Pumps Inc Barnes Pumps Inc 1987 1997 1998 2002 Alteration Rights Reserved Printed in U S A WARNING The engine exhaust from this product contains chemicals known to the State ...

Page 3: ...ngs DO NOT insert fingers in pump with power connected Always wear eye protection when working on pumps Make sure lifting handles are securely fastened each time before lifting DO NOT operate pump without safety devices in place Always replace safety devices that have been removed during service or repair Secure the pump in its operating position so it can not tip over fall or slide DO NOT exceed ...

Page 4: ...ile 80 60 03 GEAR CASE Aluminum Class 319 GEAR COVER Aluminum Class 319 BEARINGS Ball FLAP VALVE Natural Rubber PINIONS Steel HC C1144 Hardened VALVE WEIGHTS Steel Iridite Plated PAINT Air Dry Enamel TRANSMISSION Enclosed Oil Bath Double Reduction GEAR RATIO 43 1 OUTPUT STROKES 60 per Minute Note speed may be adjusted between approx 50 and 65 strokes per minute ENGINE Make Model Briggs Stratton 19...

Page 5: ... Ductile 80 60 03 INTERMEDIATE GEAR Ductile 80 60 03 GEAR CASE Aluminum Class 319 GEAR COVER Aluminum Class 319 BEARINGS Ball FLAP VALVE Natural Rubber PINIONS Steel HC C1144 Hardened VALVE WEIGHTS Steel Iridite Plated PAINT Air Dry Enamel TRANSMISSION Enclosed Oil Bath Double Reduction GEAR RATIO 43 1 OUTPUT STROKES 60 per Minute Note Speed may be adjusted between approx 50 and 65 strokes per min...

Page 6: ...ture s recommendations Be familiar with engine START UP and SHUT DOWN procedures before operation Operate engine in accordance with the manufacture s instructions 2 Check oil level in the pump transmission If it is not up to the oil level plug in the cover top off with an SAE 80 90 EP gear lub Transmission oil capacity is 20 oz 550ml 3 For best performance locate pump as close to water as possible...

Page 7: ... transmission oil after the first 40 hours of operation Use an SAE80 90 wt EP gear lube Capacity is 20 oz 550ml Fill to the oil level plug in the transmission cover Check oil level periodically and change oil every 400 hours 11 Change engine oil per manufacturer s specifications Check oil level frequently SECTION E TROUBLE SHOOTING If your pump does not prime or operate properly check the followin...

Page 8: ...Fig 1 8 Manual Index HOME MENU ...

Page 9: ...Fig 2 9 Manual Index HOME MENU ...

Page 10: ...Fig 3 10 Manual Index HOME MENU ...

Page 11: ...ing Washer P3360 P3317 23 1 Connecting Rod P3352 P3305 24 1 Grease Fitting 3 16 Alemite 1728B W33 3 16 W33 3 16 25 1 Connecting Rod Bearing P5582 P5581 26 2 Woodruff Key 1 4 x 7 8 W70 807 W70 807 27 1 Crank Arm P5584 P5583 28 1 Set Socket Hd Screw 5 16 18 x 5 16 BC090 C031 031 same 29 1 Hex Screw 1 2 13 x 1 1 2 A010 050 0150 A010 050 0150 30 1 Lip Seal W35 C12329CRW1 same 31 1 Hex Jam Nut 5 8 18 E...

Page 12: ...t P3319R P3319R 74 1 Bracket Left P3319L P3319L 75 1 Extension Angle Right P4869R P4869R 76 1 Extension Angle Left P4869L P4869L 77 1 Coupling Guard P4873A P4873A 78 1 Engine Support P5609 P5609 79 1 Engine B S 192432 8HP 3600RPM W1 D110 W1 D110 103 4 Hex Screw 3 8 x 1 1 2 A 010 037 0150 A 010 037 0150 81 4 Hex Screw 5 16 x 1 3 4 82 6 Hex Screw 3 8 x 1 A 010 037 0100 A 010 037 0100 83 10 Hex Screw...

Page 13: ...ing Washer P3360 P3317 23 1 Connecting Rod P3352 P3305 24 1 Grease Fitting 3 16 Alemite 1728B W33 3 16 W33 3 16 25 1 Connecting Rod Bearing P5582 P5581 26 2 Woodruff Key 1 4 x 7 8 W70 807 W70 807 27 1 Crank Arm P5584 P5583 28 1 Set Socket Hd Screw 5 16 18 x 5 16 BC090 C031 031 same 29 1 Hex Screw 1 2 13 x 1 1 2 A010 050 0150 A010 050 0150 30 1 Lip Seal W35 C12329CRW1 same 31 1 Hex Jam Nut 5 8 18 E...

Page 14: ...t P3319R P3319R 74 1 Bracket Left P3319L P3319L 75 1 Extension Angle Right P4869R P4869R 76 1 Extension Angle Left P4869L P4869L 77 1 Coupling Guard P4873A P4873A 78 1 Engine Support P5609 P5609 79 1 Engine B S 192432 8HP 3600RPM W1 D110 W1 D110 103 4 Hex Screw 3 8 x 1 1 2 A 010 037 0150 A 010 037 0150 81 4 Hex Screw 5 16 x 1 3 4 82 6 Hex Screw 3 8 x 1 A 010 037 0100 A 010 037 0100 83 10 Hex Screw...

Page 15: ...anty contact your local Crane Pumps Systems Inc Distributor RETURNED GOODS RETURN OF MERCHANDISE REQUIRES A RETURNED GOODS AUTHORIZATION CONTACT YOUR LOCAL CRANE PUMPS SYSTEMS INC DISTRIBUTOR Products Returned Must Be Cleaned Sanitized Or Decontaminated As Necessary Prior To Shipment To Insure That Employees Will Not Be Exposed To Health Hazards In Handling Said Material All Applicable Laws And Re...

Page 16: ...performance Any additional guarantees in the nature of performance specifications must be in writing and such writing must be signed by our authorized representative Due to inaccuracies in field testing if a conflict arises between the results of field testing conducted by or for user and laboratory tests corrected for field performance the latter shall control Components or accessories supplied b...

Page 17: ...Charge of Pump Phone Purchased from Crane Pumps Systems Representative Distributor Pumps Model Brand Part Number Trailer type Skid Mounted Contractor Trailer Highway Trailer Other Condition of Equipment Good Fair Poor Condition of Trailer Good Fair Poor Condition of Pump Good Fair Poor Condition of Engine Good Fair Poor Startup Checklist BEFORE Starting Engine Check Add Engine Oil Check Add Fuel A...

Page 18: ... Date I Certify this report to be accurate Name of Start Up person Employed by Date Date and Time of Start Up Present at Start Up Engineer Operator Contractor Other To be filled out by factory Start Up form checked by Date warranty registration mailed Manual Index HOME MENU ...

Page 19: ...RT NO BRAND FOLD HERE IMPORTANT WARRANTY REGISTRATION Your product is covered by the enclosed Warranty Complete the Warranty Registration Form and returned to Crane Pumps Systems Inc Warranty Service Group IMPORTANT If you have a claim under the provision of the warranty contact your local Crane Pumps Systems Inc Distributor Manual Index HOME MENU ...

Page 20: ...CRANE PUMPS SYSTEMS INC WARRANTY SERVICE GROUP 420 THIRD STREET P O BOX 603 PIQUA OHIO 45356 0603 U S A PLACE STAMP HERE FOLD HERE AND TAPE DO NOT STAPLE Manual Index HOME MENU ...

Reviews: