![Crane 3SHV Installation And Operation Manual Download Page 10](http://html.mh-extra.com/html/crane/3shv/3shv_installation-and-operation-manual_2679145010.webp)
10
CHART ‘D’
MODEL
NO
HP
V
O
LT
PH
Hz
RPM (Nom)
NEMA ST
AR
T
CODE
FULL LOA
D
AMPS
SER
VICE
FA
CT
OR
SER
VICE
FA
CT
OR
AMPS
LOCKED R
O
T
OR
AMPS
CORD P/N
▲
CORD SIZE
CORD O.
D
.
WINDING
RESIST
ANCE
6SHVL Pump
6SHVL20064
20.0
208
3
60
1750
G
63.0
1.2
74.6
323.0
138318
6/4 - 18/4
1.47 ± .03
0.098
6SHVL25094
25.0
208
3
60
1750
G
77.8
1.2
93.4
359.0
138319A
2/4 - 18/4
1.47 ± .03
0.098
230
71.4
1.2
82.3
6SHVL30094
30.0
208
3
60
1750
E
93.4
1.2
116.9
359.0
138319A
2/4 - 18/4
1.47 ± .03
0.098
230
82.3
1.2
98.7
6SHVL40034
40.0
230
3
60
1750
E
106.0
1.2
126.4
486.0
138319A
2/4 - 18/4
1.47 ± .03
.063
6SHVL40044
40.0
460
3
60
1750
E
53.0
1.2
63.2
243.0
138318
6/4 - 18/4
1.47 ± .03
.248
6SHVL40054
40.0
575
3
60
1750
E
42.4
1.2
50.6
194.4
138317
8/4 - 18/4
1.12 ± .02
.382
6SHVL50044
50.0
460
3
60
1750
E
67.1
1.2
79.0
339.0
138318
6/4 - 18/4
1.47 ± .03
.15
6SHVL50054
50.0
575
3
60
1750
E
53.7
1.2
63.2
271.2
138318
6/4 - 18/4
1.47 ± .03
.245
6SHVL60044
60.0
460
3
60
1750
E
79.0
1.2
95.5
339.0
138319A
2/4 - 18/4
1.47 ± .03
.15
6SHVL60054
60.0
575
3
60
1750
E
63.2
1.2
76.4
271.2
138318
6/4 - 18/4
1.47 ± .03
.245
6SHVL20096
20.0
208
3
60
1150
H
60.3
1.2
71.5
354.0
138318
6/4 - 18/4
1.47 ± .03
.111
7
230
57.2
1.2
69.8
6SHVL25096
25.0
208
3
60
1150
G
75.2
1.2
90.8
354.0
138319A
2/4 - 18/4
1.47 ± .03
.111
7
230
70.8
1.2
82.6
6SHVL25046
25.0
460
3
60
1150
G
35.4
1.2
41.3
177.0
138317
8/4 - 18/4
1.12 ± .02
.4397
6SHVL25056
25.0
575
3
60
1150
G
28.3
1.2
33.0
141.6
138317
8/4 - 18/4
1.12 ± .02
.6857
6SHVL30096
30.0
208
3
60
1150
E
90.8
1.2
114.9
354.0
138319A
2/4 - 18/4
1.47 ± .03
.111
7
230
82.6
1.2
99.7
6SHVL30046
30.0
460
3
60
1150
E
41.3
1.2
49.9
177.0
138317
8/4 - 18/4
1.12 ± .02
.4397
6SHVL30056
30.0
575
3
60
1150
E
33.0
1.2
39.9
141.6
138317
8/4 - 18/4
1.12 ± .02
.6857
6SHVL40036
40.0
230
3
60
1150
E
110.4
1.2
131.8
476.0
138319A
2/4 - 18/4
1.47 ± .03
.0819
6SHVL40046
40.0
460
3
60
1150
E
55.2
1.2
65.9
238.0
138318
6/4 - 18/4
1.47 ± .03
.3277
6SHVL40056
40.0
575
3
60
1150
E
44.2
1.2
52.7
190.4
138317
8/4 - 18/4
1.12 ± .02
.5443
Moisture and
Temperature sensor leads are integral to power cord.
Winding Resistance ± 7.5%
Winding resistance measured in OHMS @ 25°C (Between Lines) at motor leads.
Pump rated for operation at ± 10% voltage at motor
.
▲ Cord Suffix: XC - 30 Feet, XF - 50 Feet, XJ - 75 Feet, or XL
- 100 Feet
▲ Cord sold separately (After March-2016 ONL
Y). Pumps built Before March-2016 refer to Cord
Assembly Kit, see page 28.
Summary of Contents for 3SHV
Page 29: ...29 FIGURE 10 SH Pump Series Cross Sections Before March 2016 FIGURE 11 SH Vortex SH Enclosed ...
Page 30: ...30 FIGURE 12 SH Enclosed Pump Series Exploded Views Before March 2016 ...
Page 33: ...33 FIGURE 13 SH Pump Series Cross Sections After March 2016 FIGURE 14 SH Vortex SH Enclosed ...
Page 34: ...34 FIGURE 15 SH Enclosed Pump Series Exploded Views After March 2016 ...
Page 59: ...Notes ...
Page 60: ...Notes ...