8
MODEL
NO
HP
V
O
LT
PH
Hz
RPM (Nom)
NEMA ST
AR
T
CODE
FULL LOA
D
AMPS
SER
VICE
FA
CT
OR
SER
VICE
FA
CT
OR
AMPS
LOCKED R
O
T
OR
AMPS
CORD P/N
▲
CORD SIZE
CORD O.
D
.
WINDING
RESIST
ANCE
4SHME Pump
4SHME30094
30.0
208
3
60
1750
E
93.4
1.2
116.9
359.0
138319
2/4 - 18/4
1.47 ± .03
0.098
230
82.3
98.7
4SHME40034
40.0
230
3
60
1750
E
106.0
1.2
126.4
486.0
138319
2/4 - 18/4
1.47 ± .03
.063
4SHME40044
40.0
460
3
60
1750
E
53.0
1.2
63.2
243.0
138318
6/4 - 18/4
1.14 ± .03
.248
4SHME40054
40.0
575
3
60
1750
E
42.4
1.2
50.6
194.4
138317
8/4 - 18/4
1.12 ± .02
.382
4SHME50044
50.0
460
3
60
1750
F
67.1
1.2
79.0
339.0
138318
6/4 - 18/4
1.14 ± .03
.15
4SHME50054
50.0
575
3
60
1750
F
53.7
1.2
63.2
271.2
138318
6/4 - 18/4
1.14 ± .03
.245
4SHME60044
60.0
460
3
60
1750
E
79.0
1.2
95.5
339.0
138319
2/4 - 18/4
1.47 ± .03
.15
4SHME60054
60.0
575
3
60
1750
E
63.2
1.2
76.4
271.2
138318
6/4 - 18/4
1.14 ± .03
.245
4SHME20096
20.0
208
3
60
1150
H
60.3
1.2
71.5
354.0
138318
6/4 - 18/4
1.14 ± .03
.111
7
230
57.2
1.2
69.8
4SHME25096
25.0
208
3
60
1150
G
75.2
1.2
90.8
354.0
138319
2/4 - 18/4
1.47 ± .03
.111
7
230
70.8
1.2
82.6
4SHME25046
25.0
460
3
60
1150
G
35.4
1.2
41.3
177.0
138317
8/4 - 18/4
1.12 ± .02
.4397
4SHME25056
25.0
575
3
60
1150
G
28.3
1.2
33.0
141.6
138317
8/4 - 18/4
1.12 ± .02
.6857
4SHME30096
30.0
208
3
60
1150
E
90.8
1.2
114.9
354.0
138319
2/4 - 18/4
1.47 ± .03
.111
7
230
82.6
1.2
99.7
4SHME30046
30.0
460
3
60
1150
E
41.3
1.2
49.9
177.0
138317
8/4 - 18/4
1.12 ± .02
.4397
4SHME30056
30.0
575
3
60
1150
E
33.0
1.2
39.9
141.6
138317
8/4 - 18/4
1.12 ± .02
.6857
4SHMEA
Pump
4SHMEA20096
20.0
208
3
60
1150
H
60.3
1.2
71.5
354.0
138318
6/4 - 18/4
1.14 ± .03
0.1
117
230
57.2
1.2
69.8
4SHMEA25096
25.0
208
3
60
1150
G
75.2
1.2
90.8
354.0
138319
2/4 - 18/4
1.47 ± .03
0.1
117
230
70.8
1.2
82.6
4SHMEA25046
25.0
460
3
60
1150
G
35.4
1.2
41.3
177.0
138317
8/4 - 18/4
1.12 ± .02
0.4397
4SHMEA25056
25.0
575
3
60
1150
G
28.3
1.2
33.0
141.6
138317
8/4 - 18/4
1.12 ± .02
0.6857
Moisture and
Temperature sensor leads are integral to power cord.
Winding Resistance ± 7.5%
Winding resistance measured in OHMS @ 25°C (Between Lines) at motor leads.
Pump rated for operation at ± 10% voltage at motor
.
▲ Cord Suffix: XF - 50 Feet, XJ - 75 Feet, or XL
- 100 Feet
▲ Cord sold separately (After March-2016 ONL
Y). Pumps built Before March-2016 refer to Cord
Assembly Kit, see page 28.
Summary of Contents for BARNES 10SHD Series
Page 27: ...27 FIGURE 10 SH Pump Series Cross Sections Before March 2016 FIGURE 11 SH Vortex SH Enclosed ...
Page 28: ...28 FIGURE 12 SH Enclosed Pump Series Exploded Views Before March 2016 ...
Page 31: ...31 FIGURE 13 SH Pump Series Cross Sections After March 2016 FIGURE 14 SH Vortex SH Enclosed ...
Page 32: ...32 FIGURE 15 SH Enclosed Pump Series Exploded Views After March 2016 ...
Page 55: ...Notes ...
Page 56: ...Notes ...