background image

4. Hanging Bracket Installation.

Turn off circuit breakers to current fixture from breaker 
panel and be sure operating light switch is turned to the 
OFF position. 

WARNING: 

Failure to disconnect power supply prior to 

installation may result in serious injury.

Remove existing fixture. 

WARNING:

 When using an existing outlet box, be sure the 

outlet box is securely attached to the building structure and 
can support the full weight of the fan. Ensure outlet box is 
clearly marked "Suitable for Fan Support." If not, it must be 
replaced with an approved outlet box. Failure to do so can 
result in serious injury.

CAUTION

Be sure outlet box is grounded properly and that a 

ground wire (

GREEN

 or bare) is present.

Install hanging bracket to outlet box, using original screws, 
spring washers and flat washers provided with new or 
original outlet box.* If installing on a vaulted ceiling, face 
opening of hanging bracket towards high point of ceiling. 
Arrange electrical wiring around the back of the hanging 
bracket and away from the bracket opening.

*

Note

: It is very important that you use the proper hardware 

when installing the hanging bracket as this will support the 
fan.

page 3

ON

OFF

ON

OFF

3. Installation Preparation.

To prevent personal injury and damage, ensure 
that the hanging location allows the blades a 
clearance of 9 feet (2.74m) from the floor and 
30in. (76cm) from any wall or obstruction. 
This fan is suitable for room sizes up to 400 
square feet (37.2 square meters).

Installation requires these tools:

Phillips screwdriver, flathead screwdriver, 
adjustable pliers or wrench, stepladder, wire 
cutters, and rated electrical tape

Vaulted ceiling 
angle is not to 
exceed 25 degrees.

downrod

installation

flushmount

installation

12f

t - 20f

t

12ft - 20ft

(3.66m - 6.1m)

9 feet

(2.74m)

(76cm)

30 

inches

This fan can be mounted with a 

downrod

on a regular (no-slope) or vaulted ceiling. The 
hanging length can be extended by purchasing 
a longer downrod (0.5in./1.27cm diameter). 
Other installation, such as 

flushmount

, is 

not

 

available for this fan.

blade edge

(3.66m - 6.1m)

hanging bracket

spring washers

outlet box screws

flat washers

Summary of Contents for VESTA VS60-LED

Page 1: ...Assembly pg 7 Light Kit Assembly Optional pg 8 Handheld Remote Control Assembly pg 9 Automated Learning Process Activating Code pg 10 Remote Control Operation pg 10 Testing Your Fan pg 10 Troubleshooting pg 11 Warranty pg 11 Parts Replacement pg 11 net weight of fan 32 4 lb 14 71 kg PRINTED IN CHINA READ THESE INSTRUCTIONS AND SAVE THEM FOR FUTURE USE For Model VS60 LED Installation Guide E192641 ...

Page 2: ...trol device or control fan speed with a full range dimmer switch Using a full range dimmer switch to control fan speed will cause a loud humming noise from fan 8 Do not operate the reverse switch until the fan has come to a complete stop Note If using remote control with reverse capability reverse fan blade direction only when on LOW speed 9 Do not insert anything between the fan blades while they...

Page 3: ... q blade 5 pieces r hardware packs page 2 d a b c 1 Unpacking Your Fan Carefully open the packaging Remove items from Styrofoam inserts Remove motor housing and place on carpet or Styrofoam to avoid damage to finish The four motor stabilization pieces may be dicarded at this time Do not discard fan carton or Styrofoam inserts should this fan need to be returned for repairs Check against parts inve...

Page 4: ...ical wiring around the back of the hanging bracket and away from the bracket opening Note It is very important that you use the proper hardware when installing the hanging bracket as this will support the fan page 3 ON OFF ON OFF 3 Installation Preparation To prevent personal injury and damage ensure that the hanging location allows the blades a clearance of 9 feet 2 74m from the floor and 30in 76...

Page 5: ...in the installation and operation of this fan motor housing motor housing downrod support red dot plug red dot If you wish to extend the hanging length of your fan you must remove the hanging ball from the downrod provided to use with an extended downrod sold separately If you wish to use the provided downrod please proceed to instructions on the following page To remove hanging ball loosen set sc...

Page 6: ...lock washer not supplied with the safety cable loop If necessary adjust the loop at the end of the safety cable The loop at the end of the safety cable should just fit over the threads on the wood screw Test safety cable by pulling on loose end with pliers If the safety cable slips the loop must be adjusted tighter Extra cable slack can be left in ceiling area Tip To prepare for threading electric...

Page 7: ... or bare wiring for fan PLEASE NOTE Wall and or handheld remote control must be used for fan to operate If you do not wish to use the wall control please proceed to Section 7 page 7 to continue with fan installation To install wall control remove existing wall switch Wire one of the wall controls with wire connectors provided as shown in diagram at right Wrap each wire connector separately with el...

Page 8: ...screw holes and then attach blade arm with lock washers and blade arm screws Before securing screws permanently repeat this procedure with remaining blade arms Secure all screws Note Tighten blade arm screws twice a year 7 Canopy Assembly Locate 2 screws on underside of hanging bracket and remove screw closest to the open end of the hanging bracket Partially loosen the other screw Lift canopy to h...

Page 9: ...te If you will NOT be using the LED light kit do NOT connect the molex Align slotted holes in LED light kit with loosened screws in fitter plate Twist LED light kit to lock Re insert screw that was previously removed and tighten all 3 screws securely Refer to diagram 2 Locate slots on glass shade and align with nodules on inside of LED light kit Gently push up on glass shade and turn to the RIGHT ...

Page 10: ...ed on inside of TOP part of remote control cover and press together firmly Place wall control into BOTTOM part of remote control cover aligning posts in top of remote control cover with post holes in the bottom Refer to diagram 3 NOTE Make sure to align narrower ends of remote control cover before closing Squeeze top and bottom of remote control cover together until you hear a click at each end in...

Page 11: ...f the handheld remote control for 5 seconds or until light blinks twice Test the light and fan functions to confirm the learning process is complete see Section 13 below handheld remote control It is recommended that you test fan before finalizing installation Restore power from circuit box and light switch if applicable Test wall control optional installation by locating ON OFF slider switch on w...

Page 12: ...otor housing yoke is are tightened securely 3 Check to be sure set screw on hanging ball is tightened securely For parts and information please refer to Parts Inventory on page 2 Craftmade Customer Support 1 800 486 4892 www craftmade com CRAFTMADE LIFETIME LIMITED WARRANTY CRAFTMADE warrants this fan to the original household purchaser for indoor use under the following provisions 1 YEAR WARRANTY...