background image

19- ENG

D24461

TROUBLESHOOTING

Performing repairs may expose voltage sources, moving
parts or compressed air sources, moving parts or

compressed air sources. Personal injury may occur. Prior to attempting
any repairs, unplug the air compressor and bleed off all air tank air
pressure.

PROBLEM

CAUSE

CORRECTION

Pressure switch does not
shut off  motor when
compressor reaches "cut-
out" pressure.

Pressure switch "cut-out"
too high.

Move On/Auto/Off lever to
the "OFF" position,  if the
outfit does not shut off
contact a Trained Service
Technician.

Contact a Trained Service
Technician.

Excessive tank
pressure - safety
valve pops off.

Tube fittings are not tight
enough.

Tighten fittings where air can
be heard escaping. Check
fittings with soapy water
solution. 

Do Not

Overtighten.

Air leaks at
fittings.

Air leaks in air
tank or at air
tank welds.

Defective air tank.

Air tank must be replaced.
Do not repair the leak.

Do not drill into, weld or
otherwise modify air tank
or it will weaken. The tank
can rupture or explode.

Air leaks
between head
and valve plate. 

Leaking seal.

Contact a Trained Service
Technician.

Possible defect in safety
valve.

Operate safety valve
manually by pulling on ring.
If valve still leaks, it should
be replaced.

Air leak from
safety valve.

Possible defect in safety
valve.

Operate safety valve
manually by pulling on ring.
If valve still leaks, it should
be replaced.

Knocking Noise.

Summary of Contents for 919.72412

Page 1: ...afety Guidelines Assembly Operation Maintenance Service and Adjustments Troubleshooting Repair Parts Model No 919 724120 CAUTION Read the Safety Guidelines and All Instructions Carefully Before Operating Sold by Sears Canada Inc Toronto Ont M5B 2B8 D24461 Rev 5 6 25 02 ...

Page 2: ...m the date of purchase This Craftsman Air Compressor warranty gives you specific legal rights and you may have other rights which vary from province to province Sears Canada Inc Toronto Ont M5B 2B8 TABLE OF CONTENTS WARRANTY 2 SPECIFICATION CHART 3 SAFETY GUIDELINES 3 8 GLOSSARY 9 ACCESSORIES 9 DUTY CYCLE 9 ASSEMBLY 10 INSTALLATION 11 12 OPERATION 13 15 MAINTENANCE 16 SERVICE AND ADJUSTMENTS 17 18...

Page 3: ... symbols below Please read the manual and pay attention to these sections IMPORTANT SAFETY INSTRUCTIONS Some dust created by power sanding sawing grinding drilling and other construction activities contains chemicals known to the State of California to cause cancer birth defects or other reproductive harm Some example of these chemicals are lead from lead based paints crystalline silica from brick...

Page 4: ...CLEAN DRY WELL VENTILATED AREA DO NOT OPERATE UNIT INDOORS OR IN ANY CONFINED AREA ALWAYS REMAIN IN ATTENDANCE WITH THE PRODUCT WHEN IT IS OPERATING ALWAYS DISCONNECT ELECTRICAL POWER BY MOVING PRESSURE SWITCH LEVER TO THE OFF POSITION AND DRAIN TANK DAILY OR AFTER EACH USE HOW TO PREVENT IT IT IS NORMAL FOR ELECTRICAL CONTACTS WITHIN THE MOTOR AND PRESSURE SWITCH TO SPARK IF ELECTRICAL SPARKS FRO...

Page 5: ...BASKETBALLS ETC 1 FAILURE TO PROPERLY DRAIN CONDENSED WATER FROM THE TANK CAUSING RUST AND THINNING OF THE STEEL TANK 2 MODIFICATIONS OR ATTEMPTED REPAIRS TO THE TANK 3 UNAUTHORIZED MODIFICATIONS TO THE UNLOADER VALVE SAFETY VALVE OR ANY OTHER COMPONENTS WHICH CONTROL TANK PRESSURE 4 EXCESSIVE VIBRATION CAN WEAKEN THE AIR TANK AND CAUSE RUPTURE OR EXPLOSION ATTACHMENTS ACCESSORIES EXCEEDING THE PR...

Page 6: ...HE TANK BREATHING THESE CONTAMINANTS CAN CAUSE SERIOUS INJURY OR DEATH SPRAYED MATERIALS SUCH AS PAINT PAINT SOLVENTS PAINT REMOVER INSECTICIDES WEED KILLERS MAY CONTAIN HARMFUL VAPORS AND POISONS RISK OF ELECTRICAL SHOCK NEVER OPERATE THE COMPRESSOR OUTDOORS WHEN IT IS RAINING OR IN WET CONDITIONS NEVER OPERATE COMPRESSOR WITH PROTECTIVE COVERS REMOVED OR DAMAGED ANY ELECTRICAL WIRING OR REPAIRS ...

Page 7: ...MED BY AUTHORIZED SERVICE CENTER PERSONNEL MOVING PARTS SUCH AS THE PULLEY FLYWHEEL AND BELT CAN CAUSE SERIOUS INJURY IF THEY COME INTO CONTACT WITH YOU OR YOUR CLOTHING ATTEMPTING TO OPERATE COMPRESSOR WITH DAMAGED OR MISSING PARTS OR ATTEMPTING TO REPAIR COMPRESSOR WITH PROTECTIVE SHROUDS REMOVED CAN EXPOSE YOU TO MOVING PARTS AND CAN RESULT IN SERIOUS INJURY HOW TO PREVENT IT WHAT CAN HAPPEN RI...

Page 8: ... OF OPERATION WITH A FIRE EXTINGUISHER DO NOT OPERATE MACHINE WITH MISSING BROKEN OR UNAUTHORIZED PARTS UNSAFE OPERATION OF YOUR AIR COMPRESSOR COULD LEAD TO SERIOUS IN JURY OR DEATH TO YOU OR OTHERS HOW TO PREVENT IT WHAT CAN HAPPEN RISK OF PROPERTY DAMAGE WHEN TRANSPORTING COMPRESSOR OIL CAN LEAK OR SPILL AND COULD RESULT IN FIRE OR BREATHING HAZARD SERIOUS INJURY OR DEATH CAN RESULT OIL LEAKS W...

Page 9: ...ing time per hour is 30 minutes When the tank pressure drops to a certain low level the motor will restart automatically The low pressure at which the motor automatically restarts is called cut in pressure Cut Out Pressure When an air compressor is turned on and begins to run air pressure in the air tank begins to build It builds to a certain high pressure before the motor automatically shuts off ...

Page 10: ... underside of air tank leg opposite wheels Remove the protective strip from the adhesive backed molded foot bumpers Attach the foot bumpers to the bottom of leg on each end Press firmly into place Installing Handles Wheels and Molded Foot Bumpers The wheels and handle do not provide adequate clearance stability or support for pulling the unit up and down stairs or steps The unit must be lifted or ...

Page 11: ...of a short circuit grounding reduces the risk of shock by providing an escape wire for the electric current This air compressor must be properly grounded The portable air compressor is equipped with a cord having a grounding wire with an appropriate grounding plug see following illustrations The plug must be used with an outlet that has been installed and grounded in accordance with all local code...

Page 12: ...e and minimum branch circuit requirements Certain air compressors can be operated on a 15 amp circuit if the following conditions are met 1 Voltage supply through branch circuit is 15 amps 2 Circuit is not used to supply any other electrical needs lights appliances etc 3 Extension cords comply with specifications 4 Circuit is equipped with a 15 amp circuit breaker or 15 amp time delay fuse NOTE If...

Page 13: ...e controls before operating the unit On Auto Off Switch Turn this switch ON to provide automatic power to the pressure switch and OFF to remove power at the end of each use Pressure Switch The pressure switch automatically starts the motor when the air tank pressure drops below the factory set cut in pressure It stops the motor when the air tank pressure reaches the factory set cut out pressure Sa...

Page 14: ... result if the following break in instructions are not closely followed This procedure is required before the air compressor is put into service and when the check valve or a complete compressor pump has been replaced 1 Make sure the On Auto Off lever is in the OFF position NOTE Pull coupler back until it clicks to prevent air from escaping through the quick connect 2 Plug the power cord into the ...

Page 15: ...e vapors If the compressor is being used to operate a sprayer DO NOT place near the spray area Before Each Start Up 1 Place On Auto Off lever to OFF and close air regulator 2 Pull regulator knob out turn counter clockwise until it stops Push knob in to lock in place 3 Attach hose and accessories NOTE The hose or accessory will require a quick connect plug if the air outlet is equipped with a quick...

Page 16: ... that the safety valve operates freely If the valve is stuck or does not operate smoothly it must be replaced with the same type of valve To Drain Tank 1 Set the On Auto Off lever to OFF 2 Pull the regulator knob out and turn counter clockwise to set the outlet pressure to zero 3 Remove the air tool or accessory 4 Pull ring on safety valve allowing air to bleed from the tank until tank pressure is...

Page 17: ...SERVICE AND ADJUSTMENTS Unit cycles automatically when power is on When doing Maintenance you may be exposed to voltage sources compressed air or moving parts Personal injuries can occur Before performing any Maintenance or repair unplug the compressor and bleed off all air pressure ALL MAINTENANCE AND REPAIR OPERATIONS NOT LISTED MUST BE PERFORMED BY TRAINED SERVICE TECHNICIAN In closed position ...

Page 18: ...r drain valve NOTE If drain valve is plugged release all air pressure The valve can then be removed cleaned then reinstalled 8 Protect the electrical cord and air hose from damage such as being stepped on or run over Wind them loosely around the compressor handle If so equipped Store the air compressor in a clean and dry location NOTE Arrow indicates flow of air Make sure it is pointing in the dir...

Page 19: ...ssure safety valve pops off Tube fittings are not tight enough Tighten fittings where air can be heard escaping Check fittings with soapy water solution Do Not Overtighten Air leaks at fittings Air leaks in air tank or at air tank welds Defective air tank Air tank must be replaced Do not repair the leak Do not drill into weld or otherwise modify air tank or it will weaken The tank can rupture or e...

Page 20: ... accessory is being used Compressor is not supplying enough air to operate accessories Prolonged excessive use of air Compressor is not large enough for air requirement Hole in hose Check valve restricted Air leaks Decrease amount of air usage Check the accessory air requirement If it is higher than the SCFM or pressure supplied by your air compressor you need a larger compressor Check and replace...

Page 21: ...Check for proper fuse You should use a time delay fuse Check for low voltage problem Check the extension cord Disconnect the other electrical appliances from circuit or operate the compressor on its own branch circuit Have checked by a Trained Service Technician Fuse blown circuit breaker tripped Extension cord is wrong length or gauge Loose electrical connections Faulty motor Check the extension ...

Page 22: ...utilisé à des fins commerciales ou comme appareil de location Cette garantie sur le compresseur d air de Craftsman vous donne des droits particuliers Il se peut que vous ayez d autres droits qui varient d une province à l autre Sears Canada Inc Toronto Ont M5B 2B8 GARANTIE 26 TABLEAU DES SPÉCIFICATIONS 27 MESURES DE SÉCURITÉ DÉFINITIONS 27 MESURES DE SÉCURITÉ IMPORTANTES 27 32 LEXIQUE 33 ACCESSOIR...

Page 23: ... un endroit bien aéré et utilisez de l équipement de sécurité approuvé portez toujours un masque facial ou respirateur homologué MSHA NIOSH bien ajusté lorsque vous utilisez de tels outils Lorsque vous utilisez un outil pneumatique il faut toujours suivre les mesures de sécurité de base afin de réduire le risque de blessures corporelles MESURES DE SÉCURITÉ DÉFINITIONS Indique un danger imminent qu...

Page 24: ...AÉRÉ LOIN DE TOUTE MATIÈRE COMBUSTIBLE ET DES VAPEURS D ESSENCE OU DE SOLVANTS SI DES MATIÈRES INFLAMMABLES DOIVENT ÊTRE VAPORISÉES SITUER LE COMPRESSEUR À UNE DISTANCE D AU MOINS 20 PIEDS DE LA ZONE DE VAPORISATION IL PEUT S AVÉRER NÉCESSAIRE D UTILISER UN BOYAU SUPPLÉMENTAIRE ENTREPOSER LES MATIÈRES INFLAMMABLES DANS UN ENDROIT SÉCURITAIRE LOIN DU COMPRESSEUR NE JAMAIS PLACER DES OBJETS CONTRE O...

Page 25: ... DE CAUSER DES DOMMAGES À LA PROPRIÉTÉ OU DES BLESSURES PORTER TOUJOURS DES LUNETTES DE PROTECTION HOMOLOGUÉES ANSI Z87 1 AVEC DES ÉCRANS LATÉRAUX LORS DE L UTILISATION DU COMPRESSEUR NE JAMAIS DIRIGER LA BUSE OU LE VAPORISATEUR VERS SOI VERS D AUTRES PERSONNES OU VERS DES ANIMAUX TOUJOURS METTRE LE COMPRESSEUR HORS FONCTION ET PURGER LA PRESSION DU BOYAU D AIR ET DU RÉSERVOIR AVANT D ENTAMER L EN...

Page 26: ...ES DE MISE À LA TERRE PRÉVENTION RISQUE PRÉVENTION RISQUE L AIR OBTENU DIRECTEMENT DU COMPRESSEUR NE DEVRAIT JAMAIS ÊTRE UTILISÉ COMME SOURCE D AIR POUR LES ÊTRE HUMAINES SI L AIR PRODUIT PAR CE COMPRESSEUR SERA UTILISÉ POUR LA RESPIRATION IL FAUT INSTALLER DES FILTRES APPROPRIÉS AINSI QUE DU MATÉRIEL DE SÉCURITÉ LES FILTRES EN LIGNE ET LE MATÉRIEL DE SÉCURITÉ UTILISÉS AVEC LE COMPRESSEUR DOIVENT ...

Page 27: ...VENTE AUTORISÉ LES PIÈCES MOBILES TELLES QUE LA POULIE LE VOLANT MOTEUR ET LA COURROIE PEUVENT ENTRAÎNER DES BLESSURES GRAVES SI ELLES ENTRENT EN CONTACT AVEC UNE PARTIE DU CORPS OU DES VÊTEMENTS EN TENTANT DE FAIRE FONCTIONNER LE COMPRESSEUR AVEC DES PIÈCES MANQUANTES OU ENDOMMAGÉES OU DE RÉPARER LE COMPRESSEUR SANS LES GARDES DE PROTECTION ON S EXPOSE AUX PIÈCES MOBILES CE QUI PEUT ENTRAÎNER DES...

Page 28: ...JAMAIS D ANNULER LES CARACTÉRISTIQUES DE SÉCURITÉ DE CE PRODUIT ASSUREZ VOUS QU UN EXTINCTEUR D INCENDIE EST DISPONIBLE DANS L AIRE DE TRAVAIL N UTILISEZ PAS L APPAREIL AVEC DES PIÈCES BRISÉES MANQUANTES OU NON AUTORISÉES RISQUE DE DOMMAGES À LA PROPRIÉTÉ PENDANT LE TRANSPORT DU COMPRESSEUR DES FUITES OU DES DÉVERSEMENTS D HUILE PEUVENT SE PRODUIRE ET ENTRAÎNER DES RISQUES D INCENDIE OU DES PROBLÈ...

Page 29: ...e à s accumuler La pression monte et atteint un niveau élevé réglé à l usine avant que le moteur ne s arrête automatiquement protégeant ainsi le réservoir d air d un taux de pression qui excèderait sa capacité La haute pression à laquelle le moteur s arrête s appelle la pression de rupture Circuit de dérivation Le circuit acheminant l électricité du tableau électrique vers la prise murale CYCLE DE...

Page 30: ...Enlevez la bande protectrice de la surface adhésive des pare chocs moulés pour pieds Attachez un pare chocs sur la surface inférieure de chaque jambe Pressez les fermement en place MISE EN GARDE Installation des poignées des roues et des pare chocs moulés pour pieds Les roues et la poignée n offrent pas assez de dégagement de stabilité ou de support pour tirer l appareil en ascendant ou en descend...

Page 31: ...é d un cordon muni d un fil de mise à la terre et d une fiche appropriée de mise à la terre voir l illustration ci dessous La fiche doit être insérée dans une prise de courant installée et mise à la terre conformément à tous les codes et ordonnances électriques locaux 1 Le cordon fourni avec cet appareil comprend une fiche avec broche de mise à la terre La fiche DOIT être insérée dans une prise de...

Page 32: ...es minimums concernant la tension et le circuit de dérivation Certains modèles de compresseur d air peuvent fonctionner sur un circuit de 15 ampères si les conditions suivantes sont satisfaites 1 la tension d alimentation au circuit de dérivation est de 15 A 2 le circuit n est pas utilisé pour alimenter d autres dispositifs électriques lumières appareils électriques etc 3 les rallonges sont confor...

Page 33: ...l Interrupteur marche automatique arrêt On Auto Off Placez cet interrupteur à la position ON pour alimenter le manostat et à la position OFF pour couper le courant après chaque utilisation Manostat Le manostat démarre automatiquement le moteur lorsque la pression dans le réservoir d air tombe à une valeur inférieure à la pression d amorçage réglée à l usine Il arrête le moteur lorsque la pression ...

Page 34: ...our la première fois et après le remplacement de la soupape de retenue ou de la pompe complète du compresseur 1 Assurez vous que le levier marche automatique arrêt On Auto Off est en position d arrêt OFF REMARQUE Tirez le raccord vers l arrière jusqu à ce qu il s enclenche afin d empêcher la fuite d air du raccord à connexion rapide 2 Branchez le cordon d alimentation dans la prise de courant du c...

Page 35: ...i le compresseur est utilisé avec un vaporisateur NE PAS placer le compresseur près de la région de vaporisation Avant chaque mise en marche 1 Placez le levier On Auto Off à la position OFF 2 Tirez le bouton du régulateur et tournez le dans le sens contraire des aiguilles d une montre jusqu à ce qu il s arrête Poussez le bouton pour le verrouiller 3 Raccordez le boyau et les accessoires REMARQUE L...

Page 36: ...e que la pression dans le réservoir se situe à environ 20 lb po2 Relâchez l anneau de la soupape de sûreté 5 Vidangez l eau du réservoir en ouvrant le robinet de vidange Tournez dans le sens contraire des aiguilles d une montre situé en bas du réservoir L eau dans le réservoir d air peut condenser Si l eau n est pas vidangée cela risque de corroder et d affaiblir le réservoir d air produisant ains...

Page 37: ... section sur l utilisation ENTRETIEN ET RÉGLAGES Le compresseur d air fonctionne automatiquement lorsqu il est sous tension En effectuant l entretien vous pourriez être exposé aux sources de tension à de l air comprimé ou aux pièces en mouvement et subir ainsi des blessures corporelles Avant de procéder à tout entretien ou réparation débranchez le compresseur et purgez tout l air pressurisé TOUS L...

Page 38: ...précédentes et exécutez l entretien requis 2 Placez le levier On Auto Off à la position OFF 3 Tournez le régulateur dans le sens contraire des aiguilles d une montre et réglez la pression de sortie à zéro 4 Débranchez l outil pneumatique ou l accessoire 5 Tirez l anneau de la soupape de sûreté pour purger l air du réservoir jusqu à ce que la pression dans le réservoir soit d environ 20 lb po2 Relâ...

Page 39: ...ntendre l air s échapper Vérifiez les raccords à l aide d une solution d eau savonneuse Ne Pas Trop Serrer Fuites d air aux raccords Fuites d air à la soupape de décharge du manostat Soupape de décharge défectueuse du manostat Contactez un technicien qualifié Fuites d air au réservoir d air ou aux soudures du réservoir Réservoir d air défectueux Le réservoir d air doit être remplacé Ne tentez pas ...

Page 40: ...aire fonctionner les accessoires Utilisation prolongée et excessive de l air Le compresseur n est pas assez gros pour la quantité d air requise Trou dans le boyau Soupape de retenue obstruée Fuites d air Diminuez la quantité d air utilisé Vérifiez les exigences en air de l accessoire Si elles sont plus élevées que la valeur SCFM pi3 min ou la pression produite par le compresseur vous avez besoin d...

Page 41: ...s utiliser un fusible ou un coupe circuit à valeur nominale supérieure à la valeur spécifiée pour le circuit de dérivation utilisé Vérifier si le fusible est du type approprié Vous devriez utiliser un fusible retardé Vérifier s il y a une condition de tension basse Vérifiez la rallonge Déconnectez tout autre appareil électrique du circuit ou branchez le compresseur sur son propre circuit de dériva...

Page 42: ...50 FR D24461 REMARQUE ...

Page 43: ...51 FR D24461 REMARQUE ...

Page 44: ...and appliances in your own home no matter who made it no matter who sold it For your nearest Sears Parts and Service location to bring in products like vacuums lawn equipment and electronics For Sears Parts Service to order the replacement parts accessories and owner s manuals that you need to do it yourself www sears ca To purchase or inquire about a Sears Maintenance Agreement call 1 800 361 666...

Reviews: