13- ENG
D29495
safety valve will protect against high
pressure by "popping out" at its
factory set pressure (slightly higher
than the pressure switch "cut-out"
setting).
Outlet Pressure Gauge:
The outlet
pressure gauge indicates the air
pressure available at the outlet side
of the regulator. This pressure is
controlled by the regulator and is
always less than or equal to the tank
pressure.
Regulator:
Controls the air pressure
shown on the outlet pressure gauge.
Turn knob clockwise to increase
pressure and counterclockwise to
decrease pressure.
Description of Operation
Become familiar with these controls
before operating the unit.
Off/Auto Switch
: Turn this switch
to"Auto" to provide automatic power
to the pressure switch and "OFF" to
shut off power at the end of each use.
Pressure Switch (not shown):
The
pressure switch automatically starts
the motor when the air tank pressure
drops below the factory set "cut-in"
pressure. It stops the motor when the
air tank pressure reaches the factory
set "cut-out" pressure.
Safety Valve:
If the pressure switch
does not shut off the air compressor
at its "cut-out" pressure setting, the
OPERATION
Know Your Air Compressor
READ THIS OWNER’S MANUAL AND SAFETY RULES BEFORE OPERATING
YOUR UNIT. Compare the illustrations with your unit to familiarize yourself with the
location of various controls and adjustments. Save this manual for future reference.
Air
Outlet
Air
Hose
Safety Valve
Regulator
Outlet
Pressure Gauge
Female
Air Chuck
Drain Valve,
not shown
Off/Auto
Switch
Power Cord
Hose Adapter
Tapered
Inflator
Blow Gun
Adapter
Extension
Tube
Inflating
Needle