background image

5 — ENG

D20346    Rev. 0    2/28/00

READ AND UNDERSTAND ALL WARNINGS BEFORE

ATTEMPTING TO OPERATE GENERATOR.

RISK OF FIRE

Turn engine off and allow it to cool
before adding fuel to the tank.
Equip area of operation with a fire
extinguisher certified to handle
gasoline or fuel fires.

Add fuel to tank in well ventilated
area. Make sure there are no
sources of ignition near the
generator.

Store fuel in a OSHA approved
container designed to hold gaso-
line. Store container in secure
location to prevent use by others.

Operate generator in a clean, dry,
well ventilated area a minimum of
four feet from any building, object
or wall.  

DO NOT OPERATE UNIT

INDOORS OR IN ANY CON-
FINED AREA.

Gasoline and gasoline vapors can
become ignited by coming in contact
with hot components such as the
muffler, engine exhaust gases, or from
an electrical spark.

Cigarettes, sparks, fires, or other hot
objects can cause gasoline or gaso-
line vapors to ignite.

Improperly stored fuel could lead to
accidental ignition. Fuel improperly
secured could get into the hands of
children or other unqualified persons.

Materials placed against or near the
generator or operating the generator
in areas where the temperature
exceeds 104° F. ambient (such as
storage rooms or garages) can
interfere with its proper ventilation
features causing overheating and
possible ignition of the materials or
buildings.

Attempting to fill the fuel tank while
the engine is running.

Sparks, fire, hot objects

Improper storage of fuel

Inadequate ventilation for genera-
tor

Never attempt to

 “speed-up”

 the

engine to obtain more perfor-
mance. Both the output voltage
and frequency will be thrown out
of standard by this practice,
endangering attachments and the
user.

Use care in filling the tank to avoid
spilling fuel.  Make sure fuel cap is
secured tightly and check engine
for fuel leaks before starting
engine.  Move generator away
from refueling area or any spillage
before starting engine.  Allow for
fuel expansion. Keep maximum
fuel level ¼ inch below the tip of
the fuel tank.  Never refuel with the
engine running.

Engine speed has been factory set to
provide safe operation. Tampering
with the engine speed adjustment
could result in overheating of attach-
ments and could cause a fire.

Spilled fuel and its vapors can be-
come ignited from hot surfaces or
sparks.

Tampering with factory set engine
speed settings.

Overfilling the fuel tank –
fuel spillage.

HAZARD

HOW TO PREVENT IT

WHAT COULD HAPPEN

Summary of Contents for 919.670031

Page 1: ...NCE TROUBLESHOOTING REPAIR PARTS IMPORTANT Read the Safety Guidelines and All Instructions Carefully Before Operating Model No 919 670031 Sold by Sears Canada Inc Toronto Ont M5B 2B8 120 VOLT 3000 WATT GENERATOR D20346 Rev 0 2 28 00 OWNER S MANUAL ...

Page 2: ...ned and operated accord ing to the instructions in this owner s manual Sears will repair free of charge any defect in material and workmanship If your Craftsman Generator is used for commercial or rental purposes this warranty applies for only 90 days from the original date of purchase FULL ONE YEAR WARRANTY ON CRAFTSMAN ENGINE For one year from the date of purchase when this Craftsman engine is m...

Page 3: ...rical system can damage appliances and WILL VOID the manufacturers warranty Never backfeed electricity through a structure s electrical system To connect to a structure s electri cal system in a safe manner always have a Double Throw Transfer Switch installed by a qualified electrician and in compli ance with local ordinances When installing a Double Throw Transfer Switch a minimum of 10 gauge wir...

Page 4: ... high load ratings to it could result in overheating of some items or their attachment wiring result ing in fire or electrical shock Attempting to use the unit when it has been damaged or when it is not func tioning normally could result in fire or electrocution Removal of guarding could expose electrically charged components and result in electrocution Operate generator in a clean dry well ventil...

Page 5: ...enerator or operating the generator in areas where the temperature exceeds 104 F ambient such as storage rooms or garages can interfere with its proper ventilation features causing overheating and possible ignition of the materials or buildings Attempting to fill the fuel tank while the engine is running Sparks fire hot objects Improper storage of fuel Inadequate ventilation for genera tor Never a...

Page 6: ...ing Generator If generator is equipped with a fuel shut off valve turn the valve to the off position before transporting to avoid fuel leaks If generator is not equipped with a fuel shut off valve drain the fuel from tank before transporting Transport fuel only in an OSHA approved container Always place generator on a protective mat when transporting to protect against damage to vehicle from leaks...

Page 7: ...ath to you or others Any gasoline operated household generator will incur voltage variations causing damage to voltage sensitive appliances or could result in fire Operation of generator in careless manner Operation of voltage sensitive appli ances without a voltage surge pro tector RISK OF UNSAFE OPERATION HAZARD HOW TO PREVENT IT WHAT COULD HAPPEN Raising or suspending generators equipped with l...

Page 8: ...r cover plates removed Avoid wearing loose fitting clothing or jewelry which could be caught by moving parts The generator contains parts which rotate at high speed during operation These parts are covered by guarding to prevent injury Contact with moving parts can result in serious injury HAZARD HOW TO PREVENT IT WHAT COULD HAPPEN During operation touch only the control surfaces of the generator ...

Page 9: ...nserts Remove generator through opening in carton IMPORTANT Before any attempt to start your genera tor be sure to check engine oil See Adding Engine Oil paragraph in the Operation section on page 12 of this manual 1 Owner s Manual 1 Generator GROUNDING THE GENERATOR A grounding lug is supplied with the generator for use when required by local electrical ordinances Refer to article 250 of the Nati...

Page 10: ...es filter element cartridge and foam pre cleaner that limits the amount of dirt that enters the engine CIRCUIT BREAKER Protects the generator from overloading 120 VOLT RECEPTACLE Used to supply 3000 watts of electrical power Protected by two 15 amp circuit breakers RECEPTACLES Your generator is equipped with a duplex 120 volt receptacle The unit is also equipped with two 15 amp and one 25 amp circ...

Page 11: ...aves have a resistive load Starting wattage and running wattage are the same B Items such as refrigerators air compressors washer dryer and hand tools that use an electrical motor have an inductive load Inductive load appliances and tools require approximately 2 to 4 times the listed wattage for starting the equipment This initial load only lasts for a few seconds on start up but is very important...

Page 12: ... is 4 cycle Use unleaded fuel only Never mix oil with gasoline Remove gas cap Add unleaded gasoline slowly to fuel tank BEFORE STARTING ENGINE Always check engine oil level before every start Running engine low of oil or out of oil could result in serious damage to the engine Adding Engine Oil Your generator has been shipped without oil in the engine Begin by removing the oil dipstick and plug Sta...

Page 13: ...oorly ventilated areas or where fuel fumes may reach an open flame CONNECTING ELECTRICAL LOADS Let engine run and warm up for five minutes after starting with no electrical load Connect loads in the following manner to prevent damage to equipment Connect inductive load equipment first inductive loads consist of refrigerators freezers water pumps air conditioners or small hand tools Connect the ite...

Page 14: ...ments that include excessive moisture dust or any corrosive vapors If these substances are on the generator clean with a cloth or soft bristle brush Do not use a garden hose or anything with water pressure to clean the generator Water may enter the cooling air slots and could possibly damage the rotor stator and the internal windings of the generator head All adjustments in the Maintenance section...

Page 15: ...ange the oil as follows To keep dirt grass clippings etc out of the engine clean the area around the drain plug and dipstickbefore removing it Remove the oil drain plug and oil fill plug Tilt the engine slightly towards the oil drain to obtain better drainage Be sure to allow ample time for complete drainage Reinstall the drain plug Tighten securely Fill the crankcase with new oil of the proper ty...

Page 16: ...gine above factory high speed set ting can be dangerous and could possibly cause per sonal injury or property damage If you believe the en gine is running too fast or slow take your generator to a Authorized Craftsman Service Center for repair and ad justment Clean Cooling System Debris may clog engine s air cooling system espe cially after prolonged operation Internal cooling fins and surfaces ma...

Page 17: ... GUIDE TROUBLESHOOTING GUIDE If you are going to store your generator for more than 30 days use the following information as a guide to prepare the generator for storage Never store generator with fuel in the tank indoors or in enclosed poorly ventilated areas where fumes can reach an open flame spark or pilot light as on a furnace water heater clothes dryer or other gas appliances Engine Preparat...

Page 18: ... defects warranty Defects are judged on normal engine performance The warranty is not related to an in use emission test Briggs Stratton Emission Control Defects Warranty Provisions The following are specific provisions relative to your Emission Control Defects Warranty Coverage It is in addition to the B S engine warranty for non regulated engines found in the Operating and Maintenance Instructio...

Page 19: ...mber of the part you wish to order Dear Customer In manufacturing this product many steps have been taken to provide you with the highest quality Unfortunately errors or omissions occasionally occur In the event that you find a missing or defec tive part please contact your nearest Sears store If you have any suggestions that would help us to improve our assembly operation instructions or this pro...

Page 20: ... RECHANGE IMPORTANT Avant d utiliser cet appareil lire les mesures de sécurité ainsi que toutes les direc tives de fonctionnement Modèle no 919 670031 GUIDE DE L UTILISATEUR Vendu par Sears Canada Inc Toronto Ont M5B 2B8 GÉNÉRATRICE DE 120 VOLTS 3000 WATTS D20346 Rev 0 2 28 00 ...

Page 21: ...n est utilisé à des fins commerciales ou comme appareil de location Cette garantie ne couvre pas les pièces non réutilisables telles que les bougies d allumage et les filtres à air qui subissent une usure normale au cours d une utilisation appropriée Cette garantie ne s applique pas sur toutes réparations nécessaires en raison d un emploi abusif ou d une négligence de la part de l utilisateur y co...

Page 22: ...as être utilisé en Californie à moins que le moteur ne soit équipé d un éclateur pare étincelles tel que décrit dans la section 4442 et à moins que l appareil ne soit maintenu en bon état de fonctionnement Des éclateurs pare étincelles sont également requis sur certaines terres forestières des États Unis et peuvent être exigés légalement sous certains autres lois et arrêtés Les gaz d échappement c...

Page 23: ...l essence Garder le niveau d essence à un maximum de 1 4 de pouce sous la partie supérieure du réservoir d essence Ne jamais remplir le réservoir lorsque le moteur est en marche L essence ou les vapeurs d essence peuvent s enflammer au contact de composantes chaudes telles que silencieux gaz d échappement du moteur ou d une étincelle électrique Les cigarettes les étincelles les incendies ou d autr...

Page 24: ...T LE TRANSPORT DE LA GÉNÉRATRICE Si la génératrice est munie d une soupape d arrêt tourner la soupape à la position fermée avant le transport de façon à éviter tout risque de fuite Si la génératrice n est pas munie d une soupape d arrêt vidanger l essence du réservoir avant le transport Ne transporter l essence que dans des contenants approuvés par l OSHA Pour le transport toujours placer la génér...

Page 25: ...T LE TRANSPORT DE LA GÉNÉRATRICE Si la génératrice est munie d une soupape d arrêt tourner la soupape à la position fermée avant le transport de façon à éviter tout risque de fuite Si la génératrice n est pas munie d une soupape d arrêt vidanger l essence du réservoir avant le transport Ne transporter l essence que dans des contenants approuvés par l OSHA Pour le transport toujours placer la génér...

Page 26: ...trices domestiques à essence produisent des variations de tension pouvant endommager les appareils sensibles aux variations de tension ou provoquer un incendie Utilisation de la génératrice avec négligence Fonctionnement des appareils électroménagers sensibles aux variations de tension sans protecteur de surtension RISQUES D UNE UTILISATION DANGEREUSE DANGER PRÉVENTION RISQUES AVERTISSEMENT Suspen...

Page 27: ...t d entrer en contact avec les pièces mobiles Pendant le fonctionnement de la génératrice certaines de ses pièces tournent à des vitesses élevées Ces pièces sont recouvertes de dispositifs de sécurité pour éviter toute blessure Le contact avec des pièces mobiles peut entraîner des blessures graves AVERTISSEMENT DANGER PRÉVENTION RISQUES Lors du fonctionnement ne toucher que les surfaces de command...

Page 28: ... ASSEMBLAGE CONTENU DE L EMBALLAGE 1 Guide de l utilisateur 1 Generator Lisez le Guide de l utilisateur Ne tentez pas de faire fonctionner cet appareil avant d avoir lu les directives sur les mesures de sécurité de assemblage le fonctionnement l entretien et l entreposage contenues dans le Guide de l utilisateur MISE À LA TERRE DE LA GÉNÉRATRICE Une patte de mise à la terre est fournie avec la gén...

Page 29: ... élément filtrant ainsi qu un filtre préliminaire en mousse réduisant la quantité de poussière entrant dans le moteur COUPE CIRCUIT Protège la génératrice contre les surcharges PRISE DE 120 VOLTS Utilisée pour fournir une puissance électrique de 3 000 watts Protégée par deux coupe circuit de 15 ampères PRISES DE COURANT Votre génératrice est équipée d une prise duplex de 120 volts L appareil est é...

Page 30: ...s et outils inductifs indiquent sur la plaque signalétique du moteur les tensions d amorçage et de service ainsi que l intensité requis Utiliser le formule suivant pour convertir la tension et l intensité en watts volts x ampères watts Toujours démarrer le moteur électrique le plus puissant en premier et brancher ensuite les autres appareils un à la fois Le guide ci dessous est fourni pour vous ai...

Page 31: ...ser de l essence ordinaire pure propre et sans plomb ayant un indice d octane d au moins 85 Ne pas mélanger de l huile avec l essence Démarrage de la génératrice MISE EN GARDE Ne jamais faire tourner le moteur à l intérieur ou dans un endroit fermé sans aération adéquate Les gaz d échappement du moteur contiennent du monoxyde de carbone un gaz toxique sans odeur Régler la commande d étranglement s...

Page 32: ...érieur dans un endroit fermé sans aération adéquate ou dans un endroit où les gaz de carburant risquent d atteindre une flamme nue Interrupteur ON OFF Soupape de coupure de carburant BRANCHEMENT DE CHARGES ÉLECTRIQUES 1 Pour réchauffer le moteur après le démarrage le laisser tourner sans charge électrique pendant cinq minutes Brancher les charges de la façon suivante afin d éviter d endommager l é...

Page 33: ...nts Changer l huile tandis que le moteur est encore chaud L huile s écoulera librement et transportera plus d impuretés S assurer que le moteur est à niveau lors du remplissage de la vérification et du changement d huile ENTRETIEN Remarque 1 Changer l huile après les premières cinq 5 heures de service à toutes les 50 heures de service par la suite et à toutes les 25 heures si l appareil est utilis...

Page 34: ...détergent liquide Exprimer l eau à l aide d un chiffon propre et laisser le filtre sécher complètement NE PAS appliquer d huile au filtre préliminaire Pour nettoyer la cartouche la taper légèrement sur une surface plate Ne pas appliquer d huile à la cartouche Remplacer la cartouche si elle est trop sale ou endommagée Une fois l entretien terminé placer le filtre préliminaire flèches vers le haut s...

Page 35: ...résistance RJ 17M de marque Champion Vérifier la distance d écartement des électrodes à l aide d un calibre d épaisseur à fils et régler la distance à 0 030 po si nécessaire Poser la bougie et bien serrer Le fait de faire tourner le moteur à une vitesse supérieure à la vitesse maximale réglée à l usine peut être dangereux et ris que de causer des blessures corporelles ou des dommages à la propriét...

Page 36: ...re utilisée pendant 30 jours ou plus utiliser les renseignements suivants comme guide pour la préparer pour l entreposage DIRECTIVES POUR L ENTREPOSAGE MISE EN GARDE Ne jamais entreposer la génératrice lorsqu il y a du carburant dans le réservoir à l intérieur ou dans un endroit fermé sans aération adéquate où les gaz risquent d atteindre une flamme nue une étincelle ou une veilleuse par exemple s...

Page 37: ...est une garantie contre les défectuosités Les défectuosités sont déterminées selon le rendement normal du moteur La garantie n est pas reliée aux essais sur les gaz d échappement lors de l utilisation Dispositions de la garantie de Briggs Stratton concernant les défectuosités du système de contrôle des émissions Les articles suivants sont des dispositions particulières sur la garantie concernant l...

Page 38: ... de suggestions nous permettant d améliorer nos instructions relatives au montage et ou à l utilisation du produit ou le produit lui mê veuillez remplir le formulaire ci dessous et l envoyer à Si vous appelex un centre d entretien local composez un des numeros suivants Regina 566 5124 Montreal 333 5740 Toronto 744 4900 Halifax 454 2444 Kitchener 894 7590 Ottawa 738 4440 Vancouver 420 8211 ENTRETIE...

Reviews: