background image

Summary of Contents for 919.168700

Page 1: ...Safety Guidelines Assembly Operation Maintenance Service and AdJustments Troubleshooting Repair Parts CAUTION Read the Safety Guidelines and All Instructions Carefully Before Operating Sears Roebuck and Co Hoffman Estates IL 60179 U S A visit our Craftsman website www sears com craftsman A05563 Rev 0 7 01 04 ...

Page 2: ...ir Compressor fails due to a defect in material or workmanship within one year from the date of purchase Sears will at its option repair or replace it free of charge Contact your nearest Sears Service Center 1 800 4 MY HOME _ to arrange for repair or return the Air Compressor to the place of purchase for replacement If this Air Compressor is used for commercial or rental purposes this warranty app...

Page 3: ...ath or serious injury _lndicates a potentially hazardous situation which if not avoided _ result in minor or moderate injury _Used without the safety alert symbol indicates a potentially hazardous situation which if not avoided may result in ro_ damage Some dust created by power sanding sawing grinding drilling and other construction activities contains chemicals known to the State of California t...

Page 4: ...To reduce the risk of fire do not allow the compressor to operate unattended How To Prevent It Always operate the compressor in a well ventilated area free of combustible materials gasoline or solvent vapors If spraying flammable materials locate compressor at least 20 feet away from spray area An additional length of hose may be required Store flammable materials in a secure location away from co...

Page 5: ...tank or its attachments The tank is designed to withstand specific operating pressures Never make adjustments or parts substitutions to alter the factory set operating pressures For essential control of air pressure you must install a pressure regulator and pressure gauge to the air outlet if not equipped of your compressor Follow the equipment manufacturers recommendation and never exceed the max...

Page 6: ...e and adequate fuse protection I r 1 1 _lm WARNING Risk to Breathing What Could Happen How To Prevent It The compressed air directly from your compressor is not safe for breathing The air stream may contain carbon monoxide toxic vapors or solid particles from the tank Breathing these contaminants can cause serious injury or death Sprayed materials such as paint paint solvents paint remover insecti...

Page 7: ...perate compressor with damaged or missing parts or attempting to repair compressor with protective shrouds removed can expose you to moving parts and can result in serious injury How To Prevent It Never operate the compressor with guards or covers which are damaged or removed Any repairs required on this product should be performed by authorized service center personnel I r 1 J _ lm WARNING Risk o...

Page 8: ...n I r 4 1 N m WARNING Risk of Unsafe Operation What Could Happen unsafe operation of your air compressor could lead to serious injury or death to you or others How To Prevent It Review and understand all instructions and warnings in this manual Become familiar with the operation and controls of the air compressor Keep operating area clear of all persons pets and obstacles Keep children away from t...

Page 9: ...ns to build It builds to a certain high pressure before the motor automatically shuts off protecting your air tank from pressure higher than its capacity The high pressure at which the motor shuts off is called cut out pressure Branch Circuit Circuit carrying electricity from electrical panel to outlet This unit is capable of powering the following Accessories The accessories are available through...

Page 10: ...aving a grounding wire with an appropriate grounding plug see following illustrations 1 The cord set and plug with this unit contains a grounding pin This plug MUST be used with a grounded outlet IMPORTANT The outlet being used must be installed and grounded in accordance with all local codes and ordinances Make sure the outlet being used has the same configuration as the grounded plug DO NOT USE ...

Page 11: ...16 AWG Voltage and Circuit Protection Refer to the specification chart for the voltage and minimum branch circuit requirements Certain air compressors can be operated on a 15 amp circuit if the following conditions are met 1 Voltage supply to circuit must comply with the National Electrical Code 2 Circuit is not used to supply any other electrical needs 3 Extension cords comply with specifications...

Page 12: ...st high pressure by popping out at its factory set pressure slightly higher than the pressure switch cut out setting Outlet Pressure Gauge The outlet pressure gauge indicates the air pressure available at the outlet side of the regulator This pressure is controlled by the regulator and is always less than or equal to the tank pressure Tank Pressure Gauge The tank pressure gauge indicates the reser...

Page 13: ...ermal overload protector If the motor overheats for any reason the overload protector will shut off the motor The motor must be allowed to cool down before restarting The compressor will automatically restart after the motor cools How to Use Your Unit How to Stop 1 Set the On Auto Off lever to OFF Before First Start up Risk of Unsafe Operation Serious damage may result if the following break in in...

Page 14: ...he air outlet is equipped with a quick connect Risk of Bursting Too much air pressure causes a hazardous risk of bursting Check the manufacturer s maximum pressure rating for air tools and accessories The regulator outlet pressure must never exceed the maximum pressure rating How to Start 1 Turn the On Auto Off lever to AUTO and allow tank pressure to build Motor will stop when tank pressure reach...

Page 15: ... and the working environment Compressor units in an extremely dirty and or hostile environment will require a greater frequency of all maintenance checks NOTE See Operation section for the location of controls To Check Safety Valve Risk of Bursting If the safety valve does not work properly over pressurization may occur causing air tank rupture or an explosion 1 Before starting compressor pull the...

Page 16: ... will not allow the compressor to operate at full capacity Keep the air filter clean at all times 1 Remove the air filter and make sure it is clean IMPORTANT Do not operate the compressor with the air filter removed 2 If dirty rinse air filter with warm water and squeeze dry 3 Replace air filter NOTE If the air filter is extremely dirty it will need to be replaced Refer to the Repair Parts for the...

Page 17: ...rn counterclockwise using a 7 8 open end wrench Note the orientation for reassembly Using a screwdriver carefully push the valve disc up and down NOTE The valve disc should move freely up and down on a spring which holds the valve disc in the closed position if not the check valve needs to be cleaned or replaced position nothing is visible In closed position disc is visible 7 Clean or replace the ...

Page 18: ... from the regulator 6 Assemble the regulator and orient as shown NOTE Arrow indicates flow or air Make sure it is pointing in the direction of air flow 4 Remove the regulator 5 Apply pipe sealant tape to the nipple Reapply pipe sealant to outlet pressure gauge and quick connect Reassemble outlet pressure gauge and quick connect Orient outlet pressure gauge to read correctly Tighten quick connect w...

Page 19: ...ve ring 6 Drain water from air tank by opening drain valve on bottom of tank Risk of Bursting Water will condense in the air tank If not drained water will corrode and weaken the air tank causing a risk of air tank rupture and possible serious personal injury 7 After the water has been drained close the drain or drain valve NOTE If drain valve is plugged release all air pressure The valve can then...

Page 20: ...ive pressure switch release valve Defective air tank Leaking seal Air leaks between head and valve plate CORRECTION Move On Auto Off lever to the OFF position if the unit does not shut off contact a Trained Service Technician Contact a Trained Service Technician Tighten fittings where air can be heard escaping Check fittings with soapy water solution Do Not Overti9hten A defective check valve resu...

Page 21: ...uctions in the Description of Operation paragraph in the Operation Section NOTE Adjust the regulated pressure under flow conditions while accessory is being used Operate safety valve manually by pulling on ring If valve still leaks it should be replaced Remove and clean or replace Decrease amount of air usage Check the accessory air requirement If it is higher than the SCFM or pressure supplied by...

Page 22: ...or proper gauge wire and cord length Remove and clean or replace Check wiring connection inside pressure switch and terminal box area Have checked by a Trained Service Technician Have checked by a Trained Service Technician Do not operate the compressor in the paint spray area See flammable vapor warning Bleed the line by pushing the lever on the pressure switch to the OFF position if the valve do...

Page 23: ...23 SP A05563 ...

Page 24: ...t o _I 1 _ _ _o_ _ m r I_ T I _1 Air Compressor Model Number 919 168700 1 Torque 15 25 In Lbs Torque 2 9 12 Ft Lbs 11 9_ 20 35 35 Torque 100 120 In Lbs 34 33 27 25 1 Torque 15 25 In Lbs 54 j_ 24 A05563 24 ENG ...

Page 25: ...egulator 23 D20675 Quick Connect Body 250 UNIV 250 M NPT 24 D23000 Drain Valve 25 Z A05565 Tank 33 Gallon 26 SSP 7811 Nut Sleeve Assembly 1 4 2 27 AC 0631 Check Valve 28 D21172 Screw 1 4 20 x 500 30 D23363 Rear Shroud 31 SSP 7813 Nut Sleeve Assembly 3 8 32 AC 0774 Isolator 3 33 AC 0292 Outlet Tube 34 SSP 7821 1 Nut Tubing 3 8 OD 35 SSG 3105 O Ring 36 Pump Assembly 45 LA 3069 Label Craftsman 46 LA ...

Page 26: ...19 168700 The picture shown is for reference only It may differ from actual unit 85 Torque 7 10 Ft Lbs 84 83 82 80 79 4 Torque 51 63 In Lbs Torque 42 48 In Lbs 78 Torque 100 120 In Lbs Q 72 74 73 Torque 100 120 In Lbs A05563 26 ENG ...

Page 27: ...F 3158 1 Screw 10 24 x 75 T25 x 80 SSG 8156 O Ring 2 759 2 7191D 073 067W 81 Z AC 0032 Valve Plate Assembly 82 CAC 1371 Muffler x83 ACG 45 O Ring 84 AC 0037 Head 85 SSF 927 Screw 250 20 x 1 125 HHW Not Illustrated A05563 Owners Manual x K 0650 Compression Ring Kit KK 4835 Connecting Rod Kit To determine which capacitor kit is needed look on label under rear shroud for motor supplier 6E Start Capac...

Page 28: ...AIRE Si este compresor de aire Craftsman fallase debido a defectos de materiales o de fabricacion dentro del at_o de su fecha de compra Sears a su opcion Io reparara o reemplazara sin costo alguno Comuniquese con el Centro de Servicio Sears mas cercano 1 800 4 MY HOME para coordinar su reparacion o devuelva el compresor de aire al lugar donde Io compro para que Io cambien Si este compresor de aire...

Page 29: ...peligrosa la cual si no es evitada podria resultar en lesiones menores o moderadas Usado sin el slmbolo de seguridad de alerta indica una situacion potencialmente riesgosa la que si no es evitada podria causar dar_os en la propiedad I hVd Z i If 1 _i I 111_611 i _ I K_ _Ia lIm a e lJ q Im7_ I m Algunos tipos de aserrin creados por maquinas electricas de lijado aserrado amolado perforado u otras ac...

Page 30: ...propiedad Para reducir el riesgo de incendio no permita que el compresor opere desatendido como prevenirlo opere siempre el eompresor ee un sector bien ventilado y libre de materiales combustibles gasolina o emanaciones de solvente En un area de rociado de materiales inflamables ubique al compresor por Io menos a 6 1m 20 pies de distancia del area de rociado Podria requerirse una extension de la m...

Page 31: ...rramientas neumaticas pistelas rociadoras acceserios activados per aire cubiertas y otros ebjetos inflables puede causar su explosion o ser arrejades pudiende ocasienar serias lesiones Para un control esencial de la presi0n debe usted instalar un regulador y un medidor de presion a la salida del aire de su compreser Si no estuviese equipado Siga las recemendaciones de los fabricantes de su eguipe ...

Page 32: ...esta a tierra l l tTo ADVERTENClA Riesgo de Inhalaci6n _ que puede occurrir El aire comprimido preveniente del compresor no es sano para respirar El ehorro de aire puede eontener monoxido de carbono vapores t6xicos o part eulas s61idas provenientes del tanque La inhalacion de dichos eontaminantes puede Ilegar a causar serias lesiones o la muerte El rociado de materiales tales como pintura solvente...

Page 33: ...tas remevidas o danadas serias lesiones si elias entraral eli col tacte con usted o sus repas Intentar operar el compresor con sus Cualquier reparaciOn requerida per este partes dafiadas o faltantes o la reparaei6n produeto debe ser efectuada per personal del compresor con sus protecciones autorizado de los servieentros removidas puede exponerlo a usted a partes movibles que podrian resultar en le...

Page 34: ...n Lasegura I_1 como prevenirlo que puede occurrir La operacion insegura de su compresor de aire podria ocasionarle serias lesiones o la muerte a usted u otros Revise y comprenda todas las instrucciones y advertencias contenidas en este manual Familiaricese con los metodos de operacion y control del compresor de aire Mantenga libre la zona de operaciones de persona alguna animales domesticos y obst...

Page 35: ...za a funcionar la presion de aire en el tanque comienza a aumentar Aumenta hasta un valor de presion alto fijado en fabrica antes de que el motor automaticamente se apague protegiendo a su tanque de aire de presiones mas altas que su capacidad La presion alta a la cual el motor se apaga se llama presion maxima de corte Ramal Circuito electrico que transporta electricidad desde el panel de control ...

Page 36: ...traciones El enchufe debe ser utilizado con un toma corriente que haya sido instalado y conectado a tierra de acuerdo a todos los codigos y ordenanzas locales 1 El cable que acompaha a esta unidad tiene una espiga para conexion a tierra Esta DEBE ser utilizada con un tomacorriente conectado a tierra IMPORTANTE El tomacorriente que sera utilizado debera haber sido conectado a tierra conforme a todo...

Page 37: ...oteccion del voltaje y del circuito Acerca del voltaje y la minima cantidad de circuitos requeridos refierase al cuadro de especificaciones Riesgo de Operacion Lasegura Ciertos compresores de aire pueden ser operados en un circuito de 15 A siempre que se cumplan las siguientes condiciones 1 Que el voltaje suministrado a traves de los ramales del circuito sea de 15 A 2 Que el circuito no sea utiliz...

Page 38: ...sion elevada saltando de acuerdo a los valores prefijados en fabrica ligeramente superiores a los de presion de corte de la Nave interruptora Manometro para controlar la presion de salida Este manometro indicara la presion de aire disponible a la salida del regulador Esta presion esta controlada por el regulador yes siempre menor o igual que la presion del tanque Man6metro de la presi6n del tanque...

Page 39: ...a apaga el motor con mucha frecuencia verifique si hay algt3n posible problema de voltaje Tambien se puede sospechar de bajo voltaje cuando 1 El motor no alcanza toda su potencia o velocidad 2 Los fusibles se queman cuando se arranca el motor las luces se atenL_an y siguen atenuadas cuando el motor es arrancado y esta en funcionamiento Como utilizar su unidad Como detenerla 1 Coloque la posicion d...

Page 40: ...mientas neumziticas y los accesorios La presi6n de salida del regulador jam_is debe exceder los valores de m_ixima presion especificados Como poner en marcha 1 Mueva la palanca On Auto Off a la posicion AUTO y deje que se incremente la presion del tanque El motor se detendra una vez alcanzado el valor de presion de corte del tanque 2 Tire de la perilla del regulador y gire en sentido horario para ...

Page 41: ...e las horas de operacion y del ambiente de trabajo Los equipos de compresion funcionando en un ambiente sumamente sucio y hostil requeriran mayor frecuencia de todas las verificaciones de mantenimiento NOTA Vea en la secci0n Operacion la ubicacion de los controles Como verificar la valvula de seguridad Riesgo de Explosi6n Si la v_ilvula de seguridad no trabaja adecuadamente ello po r_ determinar l...

Page 42: ...Perrnitir que el cornpresor se enfrie antes de darle servicio Un filtro de aire sucio no permitira que el compresor opere a plena capacidad Mantenga el filtro de aire limpio en todo momento 1 Extraiga el reten del filtro de aire 2 Retire el filtro de aire y asegL_rese de que este limpio IMPORTANTE No opere el compresor sin el filtro de aire 3 Si esta sucio enjuague el filtro de aire con agua tibia...

Page 43: ...ire y el interruptor de presion Retire cuidadosamente la tuberla de alivio de presion de la valvula de retenci0n Desenrosque la valvula de retenci0n girandola hacia la izquierda usando una Ilave de boca de 7 8 plug 22 mm Tome nora de la orientacion para volverla a ensamblar Usando un destornillador empuje con cuidado el disco de la valvula hacia arriba y hacia abajo NOTA El disco de la valvula deb...

Page 44: ...l regulador 6 Ensamble el regulador y orientelo de acuerdo a Io mostrado NOTA La flecha indica el sentido del flujo del aire Asegurese que este apuntando a la direcci0n en la que fluye el aire Aplique cinta selladora de caherlas sobre el niple del tubo vertical 7 8 Reaplique sellador de caherlas al manometro de presion externa y a la conexion rapida Rearme el manometro de presi0n de salida y el co...

Page 45: ...e seguridad 6 Drene el agua del tanque de aire abriendo la valvula de drenaje ubicada en el rondo del tanque Riesgo de Explosion El agua se condensa dentro del tanque de aire Si no se drena ella corroera debilitando la paredes del tanque de aire originando un riesgo de ruptura de sus paredes 7 Una vez que el agua haya sido drenada cierre la valvula de drenaje NOTA Si la valvula de drenaje estuvies...

Page 46: ...el equipo no corta contacte a un tecnico calificado para el servicio Contacte a un tecnico de servicio calificado Ajuste las conexiones en las que el aire puede ser escuchado escapandose Verifique las conexiones con solucion jabonosa y agua NO SOBREAJUSTE Una valvula de retencion defectuosa causa una fuga constante de aire en la valvula de alivio de presion cuando hay presion en el tanque y se apa...

Page 47: ... dahado Regulador dahado CORRECCION Si hubiese una calda excesiva de presion durante el uso del accesorio ajuste el regulador de acuerdo alas instrucciones de la seccion Operaci0n NOTA Ajuste la presion regulada bajo condiciones de flujo mientras se este usando el accesorio Opere la valvula de seguridad manualmente tirando de su anillo Si la valvula aun pierde debera ser reemplazada Extraiga y lim...

Page 48: ... cordon Extraiga limpie o reemplace Compruebe la conexion de cableado dentro del interruptor de presion y del area de la caja de terminales Haga inspeccionar por un tecnico capacitado de servicio Haga inspeccionar por un tecnico capacitado de servicio No haga funcionar el compresor en el area de pintura por rociado Vea la advertencia acerca de vapores inrlamables Purgue la Iinea empujando la palan...

Page 49: ...49 SP A05563 ...

Page 50: ...A05563 50 SP ...

Page 51: ...cer una compra inteligente Su nueva unidad Crafisman _ esta diser ada y tabricada para ar os de operacion confiable pero como todos los productos de calidad podrfan requirir reparaciones de vez en cuando Ahf es cuando el Contrato de Proteccion para Reparaciones le puede ahorrar dinero y molestias Cornpre ahora un Contrato de Proteccidn para Reparaciones y protejase contra apuros y gastos inesperad...

Page 52: ...ums lawn equipment and electronics call or go on line for the nearest Sears Parts and Repair Center 1 800 488 1222 Anytime day or night U S A onty www sears com iiiiiil il il il il il il il il il il il iiiiiiiiiiiiii iiiiiiiiiiiiii iiiiiiiiiiiiii iiiiiiiiiiiiii iiiiiiiiiiiiii iiiiiiiiiiiiii iiiiiiiiiiiiii iiiiiiiiiiiiii iiiiiiiiiiiiii iiiiiiiiiiiiii iiiiiiiiiiiiii iiiiiiiiiiiiii iiiiiiiiiiiiii iii...