11 - ENG
D24072
MAINTENANCE
Customer Responsibilities
Daily or
after
each use
Before
each use
Check Safety Valve
Drain Tank
Air Filter
Air compressor pump intake and exhaust valves
To Check Safety Valve
If the safety valve does
not work properly, over-
pressurization may occur, causing air tank
rupture or an explosion. Before starting
compressor, pull the ring on the safety valve
to make sure that the safety valve operates
freely. If the valve is stuck or does not operate
smoothly, it must be replaced with the same
type of valve.
To Drain Tank
1.
Set the On/Auto/Off lever to “OFF”.
2.
Pull the regulator knob out and turn clockwise to
set the outlet pressure to zero.
3.
Remove the air tool or accessory.
4.
Pull ring on safety valve allowing air to bleed from
the tank until tank pressure is approximately 20
psi. Release safety valve ring.
5.
Drain water from air tank by opening drain valve
(counter-clockwise) on bottom of tank.
Water will condense in
the air tank. If not
drained, water will corrode and weaken the air
tank causing a risk of air tank rupture.
●
●
Frequently
●
NOTE:
See “Operation” section for the location of controls.
To ensure efficient operation and longer life of the air compressor outfit, a routine maintenance schedule should
be prepared and followed. The following routine maintenance schedule is geared to an outfit in a normal working
environment operating on a daily basis. If necessary, the schedule should be modified to suit the conditions
under which your compressor is used. The modifications will depend upon the hours of operation and the
working environment. Compressor outfits in an extremely dirty and/or hostile environment will require a greater
frequency of all maintenance checks.
Unit cycles automatically when power is on. When performing maintenance, you may
be exposed to voltage sources, compressed air, or moving parts. Personal injuries
can occur. Before performing any maintenance or repair, disconnect power source from the compressor
and bleed off all air pressure.
Yearly
●
6.
After the water has been drained, close the drain
valve (clockwise). The air compressor can now
be stored.
NOTE
: If drain valve is plugged, release all air pressure.
The valve can then be removed, cleaned, and
reinstalled.
Air Filter - Inspection and Replacement
Hot surfaces. Risk of
burn. Compressor heads
are exposed when filter cover is removed.
Allow compressor to cool prior to servicing.
Keep the air filter clean at
all times. Do not operate
the air compressor with the air filter removed.
A dirty air filter will not allow the compressor pump to
operate at full capacity. Before you use the
compressor pump, check the air filter to be sure it is
clean and in place.
If it is dirty, replace it with a new filter. On some
models,the filter may be removed by using a pair of
needle nose pliers or a screwdriver. Pull or pry out the
old filter and carefully clean the filter area. Push in the
new air filter.
Summary of Contents for 919.167460
Page 34: ...34 SP D24072 ...
Page 35: ...35 SP D24072 ...