12- ENG
OPERATION
kNOW YOUR AIR COMPRESSOR
READ THIS OWNER’S MANUAL AND SAFETY RULES BEFORE OPERATING
YOUR UNIT. Compare the illustrations with your unit to familiarize yourself with the
location of various controls and adjustments. Save this manual for future reference.
VOLTAGE AND CIRCUIT
PROTECTION
Refer to the specification chart for the
voltage and minimum branch circuit
requirements.
Certain air
compressors can
be operated on a 15 amp circuit if
the following conditions are met.
1. Voltage supply to circuit must
comply with the National Electrical
Code.
2. Circuit is not used to supply any
other electrical needs.
3. Extension cords comply with
specifications.
4. Circuit is equipped with a 15 amp
circuit breaker or 15 amp time
delay fuse.
NOTE:
If compressor
is connected to a circuit protected
by fuses, use only time delay
fuses. Time delay fuses should be
marked "D" in Canada and "T" in
the US.
If any of the above conditions cannot
be met, or if operation of the compres-
sor repeatedly causes interruption
of the power, it may be necessary to
operate it from a 20 amp circuit. It is
not necessary to change the cord set.
Air Outlet
Air
Hose
Safety Valve
Regulator
Outlet
Pressure Gauge
Female
Air Chuck
Off (O)/Auto (I)
Switch
Power Cord
Hose
Adapter
Tapered
Nozzles
Inflation Needle
High Flow
Inflator/Deflator
Adapter Body
Nozzles to be used
with the High Flow
inflator/Deflator
adapter body
Tank
pressure
Gauge
Thread Seal
Tape