Page 1: ...mbly Operation Maintenance Service and Adjustments Troubleshooting Repair Parts CAUTION Read the Safety Guidelines and All Instructions Carefully Before Operating Sears Roebuck and Co Hoffman Estates IL 60179 U S A Visit our Craftsman website www sears com craftsman N01 421 2 Rev 0 7 24 08 ...

Page 2: ...ANTY If this product fails due to a defect in material or workmanship within one year from the date of purchase Sears will at its option repair or replace it free of charge Contact Sears at 1 800 4 MY HOME to arrange for repair or return it to the place of purchase for replacement If this product is used for commercial or rental purposes this warranty applies for only ninety days from the date of ...

Page 3: ...ill result in death or serious inNury _ ndicates a potentially hazardous situation which if not avoided could result in death or serious injury_ _ ndicates a potentially hazardous situation which if not avoided _ result in minor or moderate injury Used without the safety alert symbol indicates a potentially hazardous situation which if not avoided may result in property damaq _ This product contai...

Page 4: ...ressor Operate compressor in an open area at least 12 30 5 cm away from any wall or obstruction that would restrict the flow of fresh air to the ventilation openings Operate compressor in a clean dry well ventilated area Do not operate unit indoors or in any confined area Always remain in attendance with the product when it is operating Always turn off and unplug unit when not in use __ RiSK TO BR...

Page 5: ...lt in a violent air tank explosion WHAT CAN HAPPEN Failure to properly drain condensed water from air tank causing rust and thinning of the steel air tank Modifications or attempted repairs to the air tank HOW TO PREVENT IT Drain air tank daily or after each use If air tank develops a leak replace it immediately with a new air tank or replace the entire corn pressor Never drill into weld or make a...

Page 6: ... powered device If it is not used properly it may cause electric shock Repairs attempted by unqualified personnel can result in serious injury or death by electrocution Electrical Grounding Failure to provide adequate grounding to this product could result in serious injury or death from electrocution Refer to Grounding Instructions paragraph in the Installation section Never operate the compresso...

Page 7: ...utes after operation Do not reach around protective shrouds or attempt maintenance until unit has been allowed to cool _r_ __ R SK FROM MOV NG PARTS Touching exposed metal such as the compressor head engine head engine exhaust or outlet tubes can result in serious burns WHAT CAN HAPPEN HOW TO PREVENT IT Moving parts such as the pulley fly wheel and belt can cause serious injury if they come into c...

Page 8: ...tion with a fire extinguisher Do not operate machine with miss ing broken or unauthorized parts Risk OF FALLING WHAT CAN HAPPEN HOW TO PREVENT IT Always operate compressor in a stable secure position to prevent accidental movement of the unit Never operate compressor on a roof or other elevated position Use additional air hose to reach high locations _ m D A portable compressor can fall from a tab...

Page 9: ...y shuts off protecting your air tank from pressure higher than its capacity The high pressure at which the motor shuts off is called cut out pressure Branch Circuit Circuit carrying elec tricity from electrical panel to outlet This unit is capable of powering the following accessories The accessories are available through the current Power and Hand Tool Catalog or full line Sears stores Accessorie...

Page 10: ...ed with a cord having a grounding wire with an appropriate grounding plug see following illustrations 1 The cord set and plug with this unit contains a grounding pin This plug MUST be used with a grounded outlet iMPORTANT The outlet being used must be installed and grounded in accordance with all local codes and ordinances 2 Make sure the outlet being used has the same configuration as the grounde...

Page 11: ...uit Protection Refer to the specification chart for the voltage and minimum branch circuit requirements Risk of Opertion Certain air compressors can be operated on a 15 amp circuit if the following conditions are met 1 Voltage supply to circuit must comply with the National Electrical Code 2 Circuit is not used to supply any other electrical needs 3 Extension cords comply with specifications 4 Cir...

Page 12: ...gher than the pressure switch cut out setting Tank Pressure Gauge The tank pressure gauge indicates the reserve air pressure in the tank Outlet Pressure Gauge The outlet pressure gauge indicates the air pressure available at the outlet side of the regulator This pressure is controlled by the regulator and is always less than or equal to the tank pressure Regulator Controls the air pressure shown o...

Page 13: ...e counter clockwise fully to permit air to escape and prevent air pressure build up in the air tank during the break in period 4 Move the On Off switch to On position The compressor will start 5 Run the compressor for 15 min utes Make sure the drain valve is open and there is minimal air pressure build up in tank 6 After 15 minutes close the drain valve by turning clockwise The air receiver will f...

Page 14: ...e ANSI Z87 1 eye protection CAN OSA Z94 3 when draining as debris can be kicked up into face Use ear protection ANSI S12 6 3 19 hearing protection as air flow noise is loud when draining To Check Safety Valve _Risk of Bursting if the safety valve does not work properly over pressurization may occur causing air tank rupture or an explosion _Risk from Flying __ Objects Always wear certified safety e...

Page 15: ... To Drain Tank in the Maintenance section 2 Unplug unit 3 Remove the hose by removing the hose clamp NOTE The hose clamp is not reusable You must purchase a new hose clamp see the Parts List or purchase a standard hose clamp at a local hardware store Hose Clamp Check Valve 6 Apply sealant to the check valve threads Reinstall the check valve turn clockwise 7 Replace hose and new hose clamp 8 Perfor...

Page 16: ...view the Maintenance section on the preceding pages and perform scheduled maintenance as necessary 2 Set the On Off switch to Off and unplug unit 3 Turn the regulator counterclock wise and set the outlet pressure to zero 4 Remove the air tool or accessory 5 Pull ring on safety valve allowing air to bleed from the tank until tank pressure is approximately 20 PSI Release safety valve ring 6 Drain wa...

Page 17: ...switch cut out too high Tube firings are nottight enough Defective air tank Leaking seal Possible ddectin safety valve Possible defect in safety valve Move On Off lever to the Off position if the outfit does not shut off contact a Trained Service Technician Contact a Trained Service Technician Tighten fittings where air can be heard escaping Check fittings with soapy water solution Do Not Overtigh...

Page 18: ...d adjust the regulator following the instructions in the Description of Operation paragraph in the Operation Section NOTE Adjust the regulated pressure under flow conditions while accessory is being used Hole in hose Check valve restricted Air leaks Damaged regulator Decrease amount of air usage Check the accessory air requirement If it is higher than the SCFM or pressure supplied by your air comp...

Page 19: ... circuit breaker with higher rating than that specified for your particular branch circuit Check for proper fuse You should use a time delay fuse Check for low voltage problem Check the extension cord Disconnect the other electrical appliances from circuit or operate the compressor on its own branch circuit Check the extension cord Check wiring connection inside terminal box Have checked by a Trai...

Page 20: ...Air Compressor Model Number 919 152160 PARTS SHOWN FOR REFERENCE ONLY 34 4 36 28 856 4 t N014212 Air Compressor MODEL NUMBER 919 15216 07 31 08 N014212 20 ENG ...

Page 21: ...ve 1 9 1000002226 Manifold incl 5 10 11 35 1 10 A16182 Quick Connect Body 2 11 A17166 Gauge 1 18 A19714 Check Valve 1 19 CAC 1254 Pump Isolator 4 24 LA 3109 Drain Tank Warning Label 1 28 LA 3108 Hot Surface Label 1 31 LA 3270 Warning Label 1 32 LA 2876 Power Cord Label 1 33 1000003194 Identification Label 1 34 N014220 Nameplate 1 35 A17135 Gauge 1 36 1000002886 Rating Label 1 21 ENG N014212 ...

Page 22: ...Air Compressor Model Number 919 152160 N014212 22 ENG ...

Page 23: ...117 A04770 Cordset 1 118 CAC 1206 1 Hose Clamp 4 119 H 7051 Air Hose 1 120 SSF 3156 Screw 1 121 Z D23825 Brush Motor Ametek 1 121 Z D27196 Brush Motor Gold Tuning 1 122 N002119 Pressure Switch 1 123 A00470 Support Handle 1 124 A05239 Bracket 1 125 A10162 Air Hose 1 128 D29132 Screw 5 140 KK 4964 Connecting Rod Kit 1 141 D30324 Ring Kit 1 142 D21127 Screw 1 0143 A19123 Screw 1 846 KK 4929 Fastener ...

Page 24: ...L DE UN ANO Siesta unidad fallase debido a defectos de materiales o de fabricaci6n dentro del ado de su fecha de compra Sears a su opci6n Io reparar o reemplazara sin costo alguno Comuniquese con Sears al 1 800 4 MY HOME para coordi nar su reparaci6n o devuelva la unidad al lugar donde Io compr6 para que Io cambien Siesta unidad se usase con fines comerciales o para alquiler esta garantia se aplic...

Page 25: ... inminente que si potencialmente no se evita causarA la rnuerte o lesiones peligrosa que si no se evita puede causar serias lesiones menores o moderadas Indica una Usado sin el simbolo de situaci6n _ seguridad de alerta indica potencialmente riesgosa que si no se una situaci6n potencialmente riesgosa la evita podria causar la rnuerte o lesiones que si no se evita podria causar da_os serias en la p...

Page 26: ...compresor Opere el compresor en un lugar abi erto con una distancia de al menos 30 5 cm 12 pulg a cualquier pared u obstrucci6n que pudiera restringir el flujo de aire fresco alas aberturas de ventilaci6n Opere el compresor en un Area limpia seca y bien ventilada No opere la unidad dentro de la casa o en un Area muy cerrada Permanezca siempre controlando el producto cuando estA en funciona miento ...

Page 27: ...el tanque de aire y provo car una explosi6n violenta del tanque _QUE PUEDE SUCEDER COMO EVITARLO No drenar correctamente el agua condensada del tanque de aire que provoca 6xido y adelgazamiento del tanque de aire de acero Modificaciones o intento de reparaci6n del tanque de aire Drene el tanque diariamente o luego de cada uso Si un tanque de aire presenta una perdida reemplAcelo inmediatamente con...

Page 28: ...que funciona con electric idad si no se Io utiliza correctamente puede provocar descargas el6ctricas Que personal no calificado intente realizar reparaciones puede provocar lesiones graves o muerte pot electro cuci6n Puesta a tierra La no colocaci6n de la puesta a tierra adecuada para este producto puede provocar lesiones graves o muerte por electrocuci6n Consulte las Instrucciones de Conexi6n a t...

Page 29: ...o toque las cubiertas protectoras ni intente realizar mantenimiento hasta que la unidad se haya enfriado QUE PUEDE SUCEDER Tocar metal expuesto como el cabezal del compresor el cabezal del motor el escape del motor o los tubos de salida puede provocar quemaduras graves i RIESGO POR PIEZAS M6VlLES QUE PUEDE SUCEDER COMO EVITARLO Las piezas m6viles como la polea el volante y la correa pueden provoca...

Page 30: ...xtintor de incendios No opere la mAquina si faltan piezas si 6stas estan rotas o si no son las autorizadas 0 RIEsGo DE CAiDAS COMO EVITAR LO Opere siempre el compresor en una posici6n estable y segura para evitar que la unidad se mueva accidental mente Nunca opere el compresor sobre un techo u otra ubicaci6n elevada Utilice una manguera de aire adicional para alcanzar las ubicaciones elevadas 0 QU...

Page 31: ...ndo a su tanque de aire de presiones m s altas que su capacidad La presi6n alta a la cual el motor se apaga se llama presi6n m xima de corte Rarnal Circuito el6ctrico que transporta electricidad desde el panel de control hasta el tomacorriente Esta unidad es suficiente para abastecer de energia el6ctrica a los siguientes accesorios Estos se encuentran disponibles a trav6s del catAlogo para herrami...

Page 32: ...rra El compresor port til de aire est equipado con un cable con un conductor y un enchufe adecuado para conexi6n a tierra vea las siguientes ilustraciones 1 El cable de esta unidad tiene un enchufe de 3 espigas para conexi6n a tierra que DEBE enchufarse en un tomacorriente conectado a tierra IMPORTANTE El tomacorriente que que se use debe estar conectado a tierra conforme a todos los c6digos y ord...

Page 33: ...aje y del circuito Refi6rase a la cartilla de voltajes para determinar los requisitos minimos que el ramal del circuito requiere _ iesgo de Operaci6n Insegura Ciertos compresores de aire pueden operearse en un circuito de 15 A siempre que se cumplan las siguientes condieiones 1 Que el voltaje suministrado al ramal cumpla con el c6digo el6ctrico nacional 2 Que el circuito no sea utilizado para alim...

Page 34: ...etro de la presi6n deJ tanque El man6metro que controla la presi6n del tanque indica la reserva de presi6n del tanque de aire Man6rnetro para controlar la presi6n de salida Este man6metro indicara la presi6n de aire disponible a la salida del regulador Esta presi6n esta controlada pot el regulador y siempre es menor o igual que la presi6n del tanque Regulador Controla la presi6n de aire indicada e...

Page 35: ...rafo Protecci6n del voltaje y del circuito en la secci6n Instalacidn de este manual 3 Abrir por completo contra el sentido del reloj para dejar escapar aire y evi tar que la presi6n del tanque aumente durante el periodo de asentamiento 4 Mueva el interruptor a la posici6n de encendido El compresor se pondrA en marcha 5 Haga funcionar el compresor durante 15 minutos AsegOrese de que la vAIvula de d...

Page 36: ...quier mantenimiento desconecte el compresor del suministro el_ctrico y dr_nele toda la presi6n de aire NOTA Vea en la secci6n Operacidn la ubicaci6n de los controles C6mo verificar la v_lvula de seguridad _ Riesgo de Explosibn Si la valvula de seguridad no trabaja adecuadamente ello podra determinar Antes de poner en marcha el motor tire del anillo de la v lvula de seguridad para confirmar que ope...

Page 37: ...6n de aire del tanque y esperar a que el compresor se enfrie Para reemplazar o limpiar la v_lvula retenci6n 1 Libere toda presi6n de aire del tanque Vea Drenaje del tanque en la secci6n Mantenimiento 2 Desenchufe el equipo 3 Saquela mangueraquitandolelaabrazadera NOTA La abrazaderano es reutilizable debe comprarotra nueva Refierasea laLista de Piezasen el Manualo compreuna abrazadera estandarparam...

Page 38: ...nas precedentes y ejecute el mantenimiento programado de acuerdo ala necesidad 2 Apague la unidad colocando el interruptor Encendido Apagado en posici6n Apagado y desenchQfela 3 Gire el regulador en sentido antihorario y fije la presi6n de salida en cero 4 Extraiga la herramienta neumAtica o el accesorio 5 Tire del anillo de la v lvula de seguridad permitiendo el purgado del aire del tanque haste ...

Page 39: ... ajustadas Tanque de aire defectuoso Mueva la palanca Encendido Apagado a la posici6n Apagado si el equipo no corta contacte a un t6cnico calificado para el servicio Contacte a un t6cnico de servicio calificado Ajuste las conexiones en las que el aire puede ser escuchado escapandose Verifique las conexiones con solu ci6n jabonosa y agua No sobreajuste El tanque de aire debe ser reemplazado No repa...

Page 40: ...presi6n durante el uso del accesorio ajuste el regulador de acuerdo alas instrucciones de la Descripci6n de opera ciones en la secci6n Operacidn NOTA Ajuste la presi6n regulada bajo condiciones de flujo mien tras se est6 usando el accesorio Disminuya la cantidad de uso de aire Verifique el requerimiento de aire del accesorio Si es mayor que SCFM o la presi6n suministrada pot su compresor de aire s...

Page 41: ... especificados parala rama de su circuito Verifique el uso del fusible adecuado Debe usarse un fusible de acci6n retardada Verifique la existencia de problemas con el bajo voltaje Verifique la extension del conductor electrico Desconecte los otros artefactos electricos del circuito u opere el compresor en su ramal de circuito correspondiente Verifique la extensi6n del conductor el6ctrico Verifique...

Page 42: ...N0142128 42 ...

Page 43: ...Su nueva unidad Craftsman esta disenada y fabricada para anos de operaci6n confiable pero como todos los productos de calidad podr a requirir reparaciones de vez en cuando Ahi es cuando el Contrato de Protecci6n Maestra le puede ahorrar dinero y molestias Compre ahora un Contrato de Protecci6n Maestra y prot_jase contra apuros y gastos inesperados El Contrato de Protecci6n Maestra tambien permite ...

Page 44: ... i i i i i i i Our Home For repair of carry in products like vacuums lawn equipment and electronics call or go on line for the nearest Sears Parts and Repair Center 1 800 488 1222 Anytime day or night U S A only www sears com To purchase a protection agreement U S A or maintenance agreement Canada on a product serviced by Sears 1 800 827 6655 u sA Pard pedir servido de reparaci6n a domicilio y par...

Reviews: