background image

Read and Save These Safety Precautions

1. Turn off electricity at main switch before wiring or servicing fan in order to avoid 

possible electrical shock.

2.  All wiring must be in accordance with the National Electric Code (ANSI/NFPA 70-

1999) and local electrical codes. Electrical installation should be performed by a 

qualified licensed electrician.

3. After making the wire connections, the wires should be spread apart with the 

grounded conductor and the equipment-grounding conductor on the one side of the 

outlet box and the ungrounded conductor on the other side of the outlet box.

4. The splices after being made should be turned upward and pushed carefully up into 

the outlet box.

5. Conductor of a fan identified as grounded conductor to be connected to grounded 

conductor of power supply, conductor of a fan identified as ungrounded conductor 

to be connected to an ungrounded conductor of power supply, conductor of fan 

identified for equipment grounding to be connected to an equipment-grounding 

conductor.

6. Fan should not be mounted in an area where it might get wet.

7. To reduce the risk of fire, electric shock or personal injury, mount to outlet box 

marked "Acceptable for Fan Support" and use mounting screws provide with the 

outlet box.

8. For safety and best operating results, we recommend that you have a qualified 

electrician assemble and install your fan.

9. WARNING:  To reduce the risk of fire or electric shock, do not use this fan with any 

solid state speed control device.

10. To reduce the risk of personal injury, do not bend the blade brackets when installing 

the brackets, balancing the blades or cleaning the fan. Do not insert foreign objects 

in between rotating fan blades.

Before Assembly

1. Make sure that the fan voltage (120) is compatible with your own electrical system.

2. Check to make sure that your carton contains all the parts mentioned in the parts 

list.

NOTE:

 When the motor is taken out of carton, please put it in a soft cloth to prevent 

any damage on the ornamental surface.

CAUTION: 

Before installing, choose a location for mounting the fan where the blades 

have at least 7 feet of clearance from all objects and floor. Mount an outlet box to the 

ceiling or use an existing box.

CAUTION: 

Do not mount fan to sheet rock or drywall type materials. To insure proper 

support, use the two #1 wood screws to secure mounting bracket to joist or beam. If the 

location you choose does not have a suitable support beam, install a 2”X4” brace between 

ceiling joists to support.

Tools You Need

1. Phillips

Screwdriver

(included)

3. Adjustable 

Wrench

2. Flat Screwdriver

4. Wire Strippers

What You Have

Parts

1A. Mounting Plate
1B.  Mounting Bracket
2. Down Rod Assembly

 6" Rods Supplied

3. Canopy
4. Fan Housing & Motor
5. Blades (sold separately)
6. Glass
7. TCS Hand Held Control
8.     Halogen Bulb
9.     Hanging Cable
10.   Flange Cover

(Downrod Assembly Only)

11.   Canopy Decorative Cover

(Downrod Assembly Only)

Qty

1
1
1

1
1
5
1
1
1
1
1
1
1

1A

2

4

6

3

5

7

MED

LOW

L-1

L-2

REV

HIGH

FAN OFF

1B

8

10

S1. Wood Screws and Washers

2

S2. Screws (for Canopy)

4

S3. Bracket Screws & Washers

2

S4. Blade Screw

16

S5. Motor Screw

11

S6. Wire Connectors

3

S7. Safety Bolt & Nut

1

S8. "J" Hook

1

S9. Zip Tie

1

S2

S3

S5

S1

S4

S6

S8

S9

S7

9

11

Parts

Qty

Summary of Contents for Triumph Fan TR52

Page 1: ...ppell TX 75019 EE UU de 8 heures 17 heures Heure standard du centre Num ro de t l copieur gratuit 877 304 1728 Email customerservice craftmade com www craftmade com P O Box 1037 650 S Royal Lane Suite...

Page 2: ...risk of personal injury do not bend the blade brackets when installing the brackets balancing the blades or cleaning the fan Do not insert foreign objects in between rotating fan blades Before Assembl...

Page 3: ...steeper than 35 Angles greater than 35 will require a 45 angle adapter Downrod Installation Vaulted Ceilings Downrod Installation Normal Ceilings D Step D Setting Frequency Switches The remote control...

Page 4: ...g Outlet Box as a secondary support means Secure Mounting Plate 1A and Mounting Bracket 1B to the outlet box A by tightening bracket screws washers S3 as shown If not mounting to an Outlet Box use Woo...

Page 5: ...r remote to function Safety Bolt Nut S7 Set Screw A Canopy 3 Canopy Decorative Cover 11 Set Screw C Downrod 2 Top Motor Housing 4 Ground Wire Ball Screw Hanging Pin Hanging Ball Threaded Set Screw Hol...

Page 6: ...le for fan support and may need to be replaced Consult a qualified electrician if in doubt Step 6 Connecting Wires 1 Connect fan wires to ceiling wires white fan wire to white outlet wire black to bla...

Page 7: ...Outlet Box as a secondary support means Secure mounting Plate 1A to the outlet box A by tightening Bracket Screws Washers S3 as shown If not mounting to an outlet box use wood screws S1 and washers S...

Page 8: ...ly 3 Fan Motor Housing 2 Top Motor Housing 4 Canopy 3 Remote Antenna Antenna Wires Flange Safety Bolt S7 Safety Bolt Hanging Wire Figure 1 4 Step 4 Attaching Hanging Cable Wire Connectors Hanging Cabl...

Page 9: ...nt outlet box marked acceptable for fan support and use mounting screws provided with the outlet box Most outlet boxes commonly used for the support of lighting fixtures are not acceptable for fan sup...

Page 10: ...or use with ceiling fan Fan and lights controlled by remote control unit Ground Black White Black White Green CAUTION Always turn off power at breaker before attempting any wire connections 7 Step 7 A...

Page 11: ...e encendido apagado y el interruptor selector de control para la pared Consulte las instrucciones de funcionamiento Problema B El ventilador es demasiado ruidoso Soluciones 1 Revise que est n apretado...

Page 12: ...estin la mise la masse de l quipement doit tre connect un conducteur de mise la masse de l quipement 6 Le ventilateur ne peut tre install dans un endroit o il pourrait tre mouill 7 Pour viter les ince...

Page 13: ...ont au moins 2 m tres 7 pi du sol C 2 1 m 84 po min 0 75 m 30 po min Pr paration Important lorsque vous utilisez une bo te de sortie existante assurez vous que cette derni re est correctement attach e...

Page 14: ...vous n installez pas le ventilateur sur une bo te de sortie utilisez les vis bois S1 et les rondelles S1 pour installer solidement l appareil une poutre du plafond N oubliez pas d ins rer les vis de l...

Page 15: ...n et fixez l crou Serrez fermement Serrez la vis de fixation A contre la tige de suspension Enfoncez le couvre bride n 4 Couvre bride n 10 sur l assemblage de la tige de suspension jusqu ce qu il couv...

Page 16: ...avec les dispositifs d clairage ne prennent pas en charge les ventilateurs et doivent tre ventuellement remplac es En cas de doute consultez un lectricien qualifi Poutre de soutien Fil de terre du sup...

Page 17: ...le haut du bo tier du moteur n 4 de la base voir la figure 1 Faites glisser les pales n 5 dans les fentes situ es sur le c t du ventilateur Fixez les pales l aide des vis pr vues cet effet S4 comme l...

Page 18: ...e condition canadienne ventilateur et du moteur Bo tier externe 2 Ampoule d halog ne Pousser le verre le haut et le tourn Bo tier du ventilateur et du moteur Bo tier externe 2 Haut du bo tier du moteu...

Page 19: ...ctez les fils du ventilateur ceux du plafond le fil de ventilateur blanc au fil de sortie blanc le fil noir au fil noir et le fil vert au fil vert Les connecteurs S6 sont fournis au cas o vous en auri...

Page 20: ...u circuit d alimentation voir la figure A Utilisez les connecteurs fournis avec le ventilateur Il ne doit y avoir aucun brin d branch ni connexion desserr e Faites pivoter les pissures vers le haut et...

Page 21: ...ces lectroniques Le poids est marqu sur le dos de la pale c t de l extr mit du moteur Toutes les pales doivent avoir le m me poids pour que le ventilateur n oscille pas 4 Un kit d quilibrage des pales...

Page 22: ...all control selector switch See operation instructions Problem B Fan is Excessively Noisy Remedies 1 Check that all screws in fan assembly are tight and properly seated 2 Check to make sure mounting b...

Page 23: ...esi n personal no doble los soportes de las aspas al instalar los soportes equilibrar las aspas o limpiar el ventilador No introduzca objetos extra os entre las aspas giratorias del ventilador 36 Herr...

Page 24: ...con vara hacia abajo cielos rasos abovedados Instalaci n con vara hacia abajo cielos rasos normales D Paso D Ajuste de los interruptores de frecuencia Ajuste de los interruptores de frecuenciaUn conju...

Page 25: ...s que se encuentran en la parte superior de la caja del motor 4 P ngalos a un lado Luego levante la caja superior del motor 4 de la base vea la figura 1 Deslice la aspa 5 a trav s de la ranura situada...

Page 26: ...TANTE El cable de antena negro debe estar conectado para que el ventilador funcione Perno y tuerca de seguridad Tornillo de fijaci n A C pula 3 Tornillo de fijaci n C Vara hacia abajo 2 Cubierta decor...

Page 27: ...l techo el cable blanco del ventilador con el cable blanco de salida negro con negro y verde con verde Se incluyen los conectores de cables S5 para su conveniencia Si hay un cable azul adicional con c...

Page 28: ...parte superior de la caja del motor 4 P ngalos a un lado Luego levante la caja superior del motor 4 de la base vea la figura 1 Deslice la aspa 5 a trav s de la ranura situada al lado del ventilador F...

Page 29: ...los en los agujeros en pabell n Apriete los tornillos firmemente 3 Caja exterior del motor del ventilador Cubierta decorativa 4 C pula 3 Antena remota Cables del control remoto 4 Para mayor seguridad...

Page 30: ...el tiempo y rozar contra la parte superior de la caja del motor Uno podr a creer que es el sonido causado por el soporte Cable de seguridad Conectores de cables S5 Tierra Verde Blanco Neutro Negro Al...

Page 31: ...cristal 9 Conexiones el ctricas Conecte los cables negros del ventilador al cable negro de salida Conecte el cable blanco del ventilador al cable blanco de salida y al cable conductor a tierra verde...

Reviews: