background image

For Model:

PAT64

net weight of fan:  27.93 lb (12.67 kg) 

PRINTED IN CHINA

READ THESE INSTRUCTIONS AND

SAVE THEM FOR FUTURE USE

Table of Contents:

Safety Tips. pg. 1
Unpacking Your Fan. pg. 2
Parts Inventory. pg. 2
Installation Preparation. pg. 3
Hanging Bracket Installation. pg. 3
Fan Assembly. pgs. 4 - 5
Wiring. pg. 5
Canopy Assembly. pg. 6
Blade Assembly. pg. 6
Switch Housing Assembly. pg. 7
Testing Your Fan. pg. 7
Troubleshooting. pg. 8
Parts Replacement. pg. 8
Warranty. pg. 8

E192641

Installation Guide

Patterson

Summary of Contents for PAT64

Page 1: ...ety Tips pg 1 Unpacking Your Fan pg 2 Parts Inventory pg 2 Installation Preparation pg 3 Hanging Bracket Installation pg 3 Fan Assembly pgs 4 5 Wiring pg 5 Canopy Assembly pg 6 Blade Assembly pg 6 Swi...

Page 2: ...t an electrician for the proper size wire connectors to use 5 Electrical diagrams are for reference only Light kits that are not packed with the fan must be CUL Canada or UL USA listed and marked suit...

Page 3: ...for repairs Check against parts inventory that all parts have been included IMPORTANT REMINDER You must use the parts provided with this fan for proper installation and safety a e b c d f i j h k g a...

Page 4: ...serious injury Remove existing fixture WARNING When using an existing outlet box be sure the outlet box is securely attached to the building structure and can support the full weight of the fan Ensur...

Page 5: ...nrod Refer to diagram 2 Thread downrod into the motor housing yoke until holes for pin and clip in downrod align with holes in yoke make sure wires do not get twisted Re insert pin and clip that were...

Page 6: ...ent fixture from breaker panel and be sure switch is turned to the OFF position CAUTION Be sure outlet box is properly grounded and that a ground wire GREEN or Bare is present Make sure all electrical...

Page 7: ...may crack and break Time Saver Washers for blade screws can be set on each blade screw prior to installing blades Locate 15 blade attachment screws washers in hardware pack Hold blade arm up to blade...

Page 8: ...itch 10 Testing Your Fan It is recommended that you test fan before finalizing installation Restore power from circuit box and wall switch if applicable Test fan speeds with pull chain Start at the OF...

Page 9: ...r replace at no charge to the original purchaser any fan motor that fails to operate satisfactorily when failure results from normal use RETURN FAN MOTOR ONLY shipping prepaid to Craftmade Industries...

Page 10: ...aci n del soporte de montaje P g 3 Ensamblaje del ventilador P gs 4 5 Instalaci n el ctrica P g 5 Colocaci n de la cubierta decorativa P g 6 Colocaci n de las aspas P g 6 Instalaci n de la caja de enc...

Page 11: ...pales del ventilador al cual correpsonda cada uno Consultar con un electricista para informarse sobre el tama o correcto de conectores para cable que se debe usar 5 Los diagramas el ctricos son nicame...

Page 12: ...paquetes de art culos de ferreter a 1 Desempaquetado del ventilador Abrir el empaque cuidadosamente Sacar los art culos del embalaje Sacar el motor y ponerlo en una alfombra o en el embalaje para evi...

Page 13: ...echo Arreglar el alambrado el ctrico los cables en la parte de atr s del soporte y lejos de la abertura del soporte Nota es muy importante usar los art culos de ferreter a correctos al instalar el sop...

Page 14: ...ello la tapa de la cubierta decorativa y la cubierta decorativa por el tubo Nota se tiene que voltear la tapa de la cubierta decorativa para que el lado brillante d al bastidor del motor Referirse al...

Page 15: ...r el cable AZUL del ventilador al cable NEGRO del techo en lugar de eso Como una medida de seguridad adicional envolver cada conector para cable por separado con cinta aisladora negro del ventilador d...

Page 16: ...los arandelas para fijar las aspas en uno de los paquetes de art culos de ferreter a Agarrar uno de los brazos para las aspas y juntarlo con una de las aspas para alinear los agujeros Introducir 3 tor...

Page 17: ...ido Empezar en estado de APAGADO sin movimiento de las aspas Con el primer tir n el ventilador estar en marcha ALTA El segundo tir n pondr el ventilador en marcha MEDIA El tercer tir n bajar el ventil...

Page 18: ...liente de CRAFTMADE al 1 800 486 4892 para acordar el reenv o del ventilador Devolver el ventilador con los gastos de env o prepagados a Craftmade Nosotros repararemos o reemplazaremos el ventilador y...

Reviews: