background image

page 11

11. Automated Learning Process./Activating Code.

CAUTION

:

 The wall and/or handheld remote control can be programmed to multiple receivers or fans. If this is 

not desired, turn wall switch off to any other programmable receiver or fan.

  
Restore electrical power and then, if using wall control, set slider switch on wall control to the ON 
position. Within 60 seconds of turning on the wall control, press and hold the 

OFF

 button on the wall 

control for 5 seconds or until light blinks twice.

  

Turn power off again for at least 5 seconds

 and then turn power back on. Within 60 seconds of restoring 

the power, press and hold the 

OFF

 button on the front of the handheld remote control for 5 seconds or 

until light blinks twice.

  
Test the fan functions to confirm learning process is complete -- 

See Section 13.

13. Testing Your Fan.

12. Remote Control Operation.

ON/OFF

 slider switch - turns 

wall control

 ON or OFF 

(ON/OFF slider switch not 
functional on handheld remote)

HIGH

 button - turns 

fan

 to HIGH speed

MED

 button - turns 

fan

 to MEDIUM speed

LOW

 button - turns 

fan

 to LOW speed

OFF

 button - turns 

fan

 OFF

L1

 button - turns 

light kit

 ON/OFF when pressed once; 

dims 

light kit

 when pressed and held down

wall control

handheld

remote control

1

1

-

1

1

-

It is recommended that you test fan before finalizing installation. Restore 
power from circuit box and light switch (if applicable). Test wall control 
(optional installation) by locating ON/OFF slider switch on wall control, then 
set to the ON position. Test light and dimmer function and then test fan 
speeds. Next, locate handheld remote control. Test the light ON/OFF 
function by pressing the L1 button; test the dimmer function by pressing the 
L1 button and holding it down for up to 5 seconds. Test fan speeds with the 
different fan speed buttons. If the wall and/or handheld remote control 
operates all of the functions of the fan, battery (batteries) has (have) been 
installed correctly. If the wall and/or handheld remote control do (does) not 
operate all of the fan/light functions, refer to "Troubleshooting" section to 
solve any issues before contacting Customer Service.
 
Turn fan completely off 

before

 moving the reverse switch (located on top of 

motor housing). Set reverse switch to recirculate air depending on the 
season:
           - LEFT position in summer (

diagram 1

)

           - RIGHT position in winter (

diagram 2

)

A ceiling fan will allow you to raise your thermostat setting in summer and 
lower your thermostat setting in winter without feeling a difference in your 
comfort.

Important

: Reverse switch must be set either 

completely LEFT

 or 

completely 

RIGHT

 for fan to function. If the reverse switch is set in the 

middle

 position 

(

diagram 3

), fan will not operate.

 
NOTE

: If the wall control/handheld remote control interferes with other 

appliances, 

turn power off first

 and then go back to the instructions in 

Section 11.

diagram 1

diagram 2

diagram 3

motor

housing

reverse
switch

Summary of Contents for MRN52

Page 1: ...arts Inventory pg 3 Installation Preparation pg 4 Hanging Bracket Installation pg 4 Fan Assembly pgs 5 6 Wiring pg 7 Canopy Assembly pg 8 Blade Assembly pg 8 Light Kit Assembly pg 9 Handheld Remote Co...

Page 2: ...m fan 8 Do not operate the reverse switch until the fan has come to a complete stop Note If using remote control with reverse capability reverse fan blade direction only when on LOW speed 9 Do not ins...

Page 3: ...ts have been included 2 Parts Inventory a canopy 1 piece b hanging bracket 1 piece c downrod and hanging ball 1 piece d canopy cover 1 piece e motor housing 1 piece f yoke cover 1 piece g fitter plate...

Page 4: ...t towards high point of ceiling Arrange electrical wiring around the back of the hanging bracket and away from the bracket opening Note It is very important that you use the proper hardware when insta...

Page 5: ...rely Refer to diagram 2 Slide yoke cover canopy cover and canopy over downrod Refer to diagram 3 Note Canopy cover must be turned with shiny side toward the motor housing Thread safety cable and wires...

Page 6: ...er in place and to lift the fan up to you once you are set on the ladder Find a secure attachment point wood ceiling joist highly recommended and secure safety cable It will be necessary to use a heav...

Page 7: ...e of hanging bracket PLEASE NOTE Wall and or handheld remote control must be used for fan to operate If you do not wish to use the wall control please proceed to Section 7 page 8 to continue with fan...

Page 8: ...na for remote control receiver must rest outside of hanging bracket WARNING To reduce the risk of serious bodily injury DO NOT use power tools to assemble the blades If screws are overtightened blades...

Page 9: ...re from motor housing to BLACK wire from LED light kit Make sure molex connections snap together completely Carefully arrange wiring within the back of LED light kit Align slotted holes in LED light k...

Page 10: ...trol cover and press together firmly Place wall control into BOTTOM part of remote control cover aligning posts in top of remote control cover with post holes in the bottom Refer to diagram 3 NOTE Mak...

Page 11: ...witch if applicable Test wall control optional installation by locating ON OFF slider switch on wall control then set to the ON position Test light and dimmer function and then test fan speeds Next lo...

Page 12: ...pany be liable for any consequential damages for breach of this or any other warranty expressed or implied whatsoever This limitation as to consequential damages shall not apply in states where prohib...

Reviews: