background image

SAFETY TIPS.

page 2

WARNING

:  To reduce the risk of electrical shock, turn off the electricity to the fan at the main fuse box or circuit panel before you begin the 

fan installation or before servicing the fan or installing accessories.

1.        

 READ ALL INSTRUCTIONS AND SAFETY INFORMATION CAREFULLY BEFORE INSTALLING YOUR FAN AND SAVE THESE 

INSTRUCTIONS.

CAUTION

:  To avoid personal injury, the use of gloves may be necessary while handling fan parts with sharp edges.

2.         Make sure all electrical connections comply with Local Codes or Ordinances, the National Electrical Code, and ANSI/NFPA 70-1999.  If 

you are unfamiliar with electrical wiring or if the house/building wires are different colors than those referred to in the 
instructions, please use a qualified electrician.

3.         Make sure you have a location selected for your fan that allows clear space for the blades to rotate, and at least seven (7) feet          

(2.13 meters) of clearance between the floor and the fan blade tips.  The fan should be mounted so that the tips of the blades are 
at least thirty (30) inches (76 centimeters) from walls or other upright structures.

4.        The outlet box and ceiling support joist used must be securely mounted, and capable of supporting at least 35 pounds (16 kilograms).  

The outlet box must be supported directly by the building structure.  Use only CETL or CUL in Canada or ETL or UL in USA listed 
outlet boxes marked "FOR FAN SUPPORT."

WARNING

:  To reduce the risk of fire, electrical shock, or personal injury, mount to the outlet box marked "Acceptable for Fan Support of 15.9 

kg (35 lb) or less," and use the mounting screws provided with the outlet box.  Most outlet boxes commonly used for the support of lighting 
fixtures are not acceptable for fan support and may need to be replaced.  Consult a qualified electrician if in doubt.

WARNING

:  To reduce the risk of fire, electrical shock, or personal injury, wire connectors provided with this fan are designed to accept only 

one 12 gauge house wire and two lead wires from the fan. If your house wire is larger than 12 gauge or there is more than one house wire to 
connect to the corresponding fan lead wires, consult an electrician for the proper size wire connectors to use.

5.         Electrical diagrams are for reference only. 
6.         After installation is complete, check that all connections are absolutely secure.
7.         After making electrical connections, spliced conductors should be turned upward and pushed carefully up into the outlet box.  The 

wires should be spread apart with the grounded conductor and the equipment-grounding conductor on opposite sides of the 
outlet box.

WARNING

:  To reduce the risk of serious bodily injury, DO NOT use power tools to assemble any part of the fan, including the blades.

WARNING

:  To reduce the risk of fire or electrical shock, do not use this fan with any solid state speed control device or control fan speed 

with a full range dimmer switch.  [Using a full range dimmer switch to control fan speed will cause a loud humming noise from fan.] 

8.        Do not operate the reverse switch until the fan has come to a complete stop. [

Note

: If using remote control with reverse capability, 

reverse fan blade direction only when on LOW speed.]

9.        Do not insert anything between the fan blades while they are rotating.

WARNING

:  To reduce the risk of personal injury, do not bend the blade arms during assembly or after installation. 

WARNING

:  To avoid personal injury or damage to the fan and other items, be cautious when working around or cleaning the fan.

10.      Do not use water or detergents when cleaning the fan or fan blades. A dry dust cloth or lightly dampened cloth will be suitable for 

most cleaning.

WARNING

:  To reduce the risk of personal injury, use 

only

 parts provided with this fan.  

The use of parts 

OTHER

 than those provided with 

this fan will void the warranty.

WARNING

:  

This fan MUST be installed with the safety cable provided with the fan. Failure to use the safety cable provided may result in 

personal injury, damage to the fan or damage to other property.

CAUTION

:  Metal cover for use without light kit will be HOT if light is left on.  To reduce the risk of personal injury, light kit must be OFF.  Do 

NOT use light button on remote control if installing metal cover.

CAUTION

:  Do NOT tamper with or attempt to repair LED component of fixture.  The light source is designed for this specific application and 

should not be serviced by untrained personnel.  If any servicing is required, call our customer service department.

11.       Light kit is d

immable to 10% with select dimmers.

Modifications not approved by the party responsible for compliance could void the user's authority to operate the equipment.  [The 
equipment refers to the remote and/or wall control and/or LED light kit.]

NOTE:  This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC Rules.  
These limits are designed to provide reasonable protection against harmful interference in a residential installation.  This equipment 
generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause 
harmful interference to radio communications.  However, there is no guarantee that interference will not occur in a particular installation.  If 
this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off 
and on, the user is encouraged to try to correct the interference by one or more of the following measures:
 

* Reorient or relocate the receiving antenna.

 

* Increase the separation between the equipment and receiver.

 

* Connect the equipment into an outlet on a circuit different from that to which the receiver is connected.

Consult the dealer or an experienced radio/TV technician for help.

The LED light kit complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) this LED light kit may not 
cause harmful interference, (2) this LED light kit must accept any interference received, including interference that may cause undesired 
operation.

Distributed by: Craftmade, 650 S. Royal Lane, Coppell, TX, 75019; 1-800-486-4892

NOTE

:  The important safety precautions and instructions appearing in the manual are not meant to cover all possible conditions and 

situations that may occur.  It must be understood that common sense and caution are necessary factors in the installation and operation of 
this fan.

Summary of Contents for Cole CLE44

Page 1: ...llation pg 4 Preparation for Wiring pg 5 Wiring pgs 5 6 Fan Assembly pg 6 Blade Assembly pg 7 Light Kit Assembly pgs 7 8 Handheld Remote Control Assembly pg 9 Automated Learning Process Activating Code pg 10 Remote Wall Control Operation pg 10 Testing Your Fan pg 10 Troubleshooting pg 11 Warranty pg 11 Parts Replacement pg 11 Cole page 1 4007498 APPROVED FOR USE IN DAMP LOCATIONS net weight of fan...

Page 2: ...pability reverse fan blade direction only when on LOW speed 9 Do not insert anything between the fan blades while they are rotating WARNING To reduce the risk of personal injury do not bend the blade arms during assembly or after installation WARNING To avoid personal injury or damage to the fan and other items be cautious when working around or cleaning the fan 10 Do not use water or detergents w...

Page 3: ...inventory that all parts have been included 2 Parts Inventory a mounting plate 1 piece b housing ring 1 piece c motor housing 1 piece d wall plate 1 piece e remote control cover 1 piece f faceplate 3 pieces g wall control 2 pieces h fitter plate 1 piece i LED light kit 1 piece j shade 1 piece k metal cover 1 piece l blade 3 pieces m hardware packs l m c a b h IMPORTANT REMINDER You must use the pa...

Page 4: ...rew Also remove screw on outer edge of mounting plate directly opposite the screw that was just removed Partially loosen the other 2 screws Note It is very important that you use the proper hardware when installing the mounting plate as this will support the fan 3 Installation Preparation downrod installation flushmount installation CANNOT be installed on angled or vaulted ceilings blade edge 7 fe...

Page 5: ...urrent fixture from breaker panel and be sure switch is turned to the OFF position CAUTION Be sure outlet box is grounded properly and that a ground wire GREEN or Bare is present Make sure all electrical connections comply with Local Codes or Ordinances and the National Electrical Code If you are unfamiliar with electrical wiring or if the house building wires are different colors than those refer...

Page 6: ...lation To install wall control remove existing wall switch Wire one of the wall controls with wire connectors provided as shown in diagram at right Wrap each wire connector separately with electrical tape as an extra safety measure Gently push wires and taped wire connectors into outlet box Install one 12 volt battery included in wall control IMPORTANT Wall control will not function unless battery...

Page 7: ...k and break Time Saver Washers for blade attachment screws can be set on each screw prior to installing blades Locate 9 blade attachment screws and washers in hardware pack Slide a blade through one of the narrow rectangular openings on the motor housing aligning holes in blade with holes in blade arm which is pre attached to the underside of the motor housing and located inside the motor housing ...

Page 8: ...tighten all 3 screws with a Phillips screwdriver If you wish to USE the light kit align grooves on shade with nodules on inside of fitter plate and push up gently on shade Twist shade to the RIGHT clockwise until shade locks into place Pull down VERY GENTLY on shade to make sure that shade is secure If you do NOT wish to use the light kit locate slots on metal cover and align with nodules inside f...

Page 9: ...part of remote control cover aligning posts in top of remote control cover with post holes in the bottom Refer to diagram 3 NOTE Make sure to align narrower ends of remote control cover before closing Squeeze top and bottom of remote control cover together until you hear a click at each end indicating that the remote control cover has closed completely IMPORTANT Store the handheld remote control a...

Page 10: ...and holding it down for up to 5 seconds Test fan speeds with the different fan speed buttons If the wall and or handheld remote control operate s all of the functions of the fan and light battery batteries has have been installed correctly If the wall and or handheld remote control do does not operate all of the fan light functions refer to Troubleshooting section to solve any issues before contac...

Page 11: ...ges shall not apply in states where prohibited Problem Fan fails to operate Solutions 1 Check wall switch to fan wall control 2 Check to be sure wall control optional use is wired properly 3 Check to be sure fan is wired properly 4 Learning process between fan handheld remote control and if applicable wall control may not have been successful and code was not activated Turn off power and repeat in...

Page 12: ...ra la instalación eléctrica Pág 5 Instalación eléctrica Págs 5 6 Instalación del ventilador Pág 6 Colocación de las aspas Pág 7 Instalación del juego de luz Págs 7 8 Ensamblaje del control remoto de mano Pág 9 Proceso de aprendizaje automático El activar el código Pág 10 Funcionamiento del control remoto control de pared Pág 10 Verificación del funcionamiento del ventilador Pág 10 Localización de ...

Page 13: ... la velocidad del ventilador causará un zumbido recio del ventilador 8 No utilizar el interruptor de reversa hasta que el ventilador se haya parado completamente Nota Si se usa un control remoto con capacidad de reversa cambiar la dirección de las aspas sólo cuando el ventilador esté en velocidad BAJA 9 No insertar ningún objeto entre las aspas mientras estén rotando ADVERTENCIA Para reducir el ri...

Page 14: ...car que se incluyeron todas RECORDATORIO IMPORTANTE Se tienen que utilizar las piezas provistas con este ventilador para una instalación adecuada y su seguridad 2 Inventario de piezas a placa de montaje 1 unidad b aro del bastidor 1 unidad c bastidor del motor 1 unidad d tapa de tomacorriente 1 unidad e cubierta del control remoto 1 unidad f tapa 3 unidades g control de pared 2 unidades h placa de...

Page 15: ...illo Quitar también el tornillo en el borde exterior de la placa de montaje que está directamente enfrente del tornillo que apenas se quitó Aflojar parcialmente los otros 2 tornillos Nota Es muy importante usar los artículos de ferretería correctos al instalar la placa de montaje puesto que sirve para sostener el ventilador Para prevenir daño corporal y otros daños estar seguro de que el lugar en ...

Page 16: ... gancho en forma de j bastidor del motor ADVERTENCIA Apagar los cortacircuitos en el panel de electricidad que suplen corriente a la caja de salida y asegurarse de que el interruptor de luz esté APAGADO PRECAUCIÓN Asegurarse de que la caja de salida esté conectada a tierra como es debido y que exista un conductor a tierra VERDE o pelado Asegurarse de que toda conexión eléctrica cumpla con los Códi...

Page 17: ...ntinuación para seguir con la instalación del ventilador Para instalar el control de pared quitar el interruptor de pared existente Alambrar uno de los controles de pared con los conectores para cable provistos así como se muestra en el diagrama al lado Como una medida de seguridad adicional envolver cada conector para cable con cinta aisladora Delicadamente meter los cables y los conectores para ...

Page 18: ...r 3 tornillos para fijar el aspa junto con las arandelas con los dedos primero y luego apretarlos bien con un destornillador de estrella Phillips Repetir el procedimiento con las demás aspas NOTA Apretar los tornillos para fijar las aspas dos veces al año Quitar 1 tornillo de la placa del motor en el lado inferior del motor y aflojar los otros 2 tornillos Alinear los agujeros con ranura en la plac...

Page 19: ...uz alinear las ranuras en la pantalla con los nódulos dentro de la placa de conexión y empujar la pantalla delicadamente hacia arriba Girar la pantalla hacia la DERECHA en sentido de las agujas del reloj hasta que se quede encajada Con MUCHO CUIDADO jalar hacia abajo en la pantalla para asegurarse de que se quedó bien sujetada Si NO desea utilizar el juego de luz alinear las ranuras en la cubierta...

Page 20: ...amente Referirse al diagrama 3 Alinear los agujeros en el control de pared con los postes que se encuentran adentro de la parte SUPERIOR de la cubierta del control remoto y apretar fijamente Colocar el control de pared dentro de la parte INFERIOR de la cubierta del control remoto alineando los postes en la parte superior de la cubierta del control remoto con los agujeros para los postes en la part...

Page 21: ...comienda poner el ventilador a prueba antes de terminar la instalación Regresar la corriente de electricidad en el cortacircuitos y el interruptor de la luz si se aplica Poner a prueba el control de pared instalación opcional localizando el interruptor corredero de APAGADO y ENCENDIDO en el control de pared luego ponerlo en posición de ENCENDIDO ON Poner a prueba la luz y la función del reductor d...

Page 22: ...los tornillos para la placa de montaje Garantía Piezas de repuesto Para piezas o información referirse al Inventario de piezas en la página 3 Servicio al cliente de Craftmade 1 800 486 4892 www craftmade com GARANTÍA LIMITADA DE POR VIDA DE CRAFTMADE CRAFTMADE garantiza este ventilador al comprador original de grupo familiar para uso interior con las siguientes condiciones GARANTÍA DE 1 AÑO CRAFTM...

Reviews: