Super Shot 60 Propane Melter Part Manual
Chapter 8 Troubleshooting
©2018 by Crafco, Inc. All Rights Reserved
………………...…………………………..……………...Illustrated Parts List 8-21
Step
Possible Cause
If . . .
3
Check for continuity in the hose from end to
end. Disconnect the three blue heating
element wires (blue) from the terminal block
inside the junction box and disconnect the five
pin plug between the hose and wand. Refer
to
NOTE
:
Check each letter
“D”, “E”, and “A”
with the three blue wires on the other end of
the hose. There should only be continuity on
one wire to each letter.
Yes, go to Step 3a.
No, either there was no continuity from one
letter to the other end of the hose or there
was more than one wire with continuity to a
letter. This hose needs to be repaired or
replaced. Contact Crafco, Inc. to send back
the hose for repair.
3a
Check the RTD sensor in the hose against the
readout in the control box. Disconnect the
black and white wires from the terminal block
in the junction box and test for ohms.
Refer to
Table 8-21 RTD Sensor Ohms vs.
Yes, the readout matches the table, go to
Step 4.
No, this hose needs to be repaired or
replaced. Contact Crafco, Inc. to send back
the hose for repair.
4
Check for continuity in the wand between “D”,
“E”, and “A”.
NOTE
:
Check between “D” and “E”, “D” and
“A”, and “A” and “E”.
Yes, go to Step 5.
No, this wand needs to be repaired or
replaced. Contact Crafco, Inc. to send back
the wand for repair.
5
Is there 12Vdc between wire labeled “BLU-
GEN” on the upper terminal block and nearby
ground source (black wire)?
Yes, check for loose or broken connections
between terminal block and the
“BATT”
terminal of generator.
No, go to Step 6.
6
Is there 12Vdc between Hose PAKSTAT blue
wire terminal #4 and black wire terminal #8?
Yes, check for loose or broken wire between
terminal #4 and the terminal block.
No, go to Step 6a.
6a
Is there 12Vdc between Hose PAKSTAT
terminal #3 Pink wire and terminal #8 black
wire?
Yes, replace hose PAKSTAT.
No, go to Step 6b.
6b
Is there 12Vdc between Hose PAKSTAT pink
wire terminal #1 and black wire terminal #8?
Yes, check for loose or broken wires
between terminal #1 and terminal #3.
No, go to Step 7.
7
Is there 12Vdc between pink wire labeled
“PNK-1 on the upper terminal block and a
nearby ground source (black wire)?
Yes, check for loose or broken wire between
terminal block and terminal #1.
No go to Step 7.
7a
Is there 12Vdc between pink wire labeled
“PNK-3 and nearby ground source (black
wire)?
Yes, call Crafco, Inc. and speak to a
customer service technician you should have
been able to find the problem.
No, replace terminal block.
Table 8-19 Hose Electrical Troubleshooting (continued)
Summary of Contents for SUPER SHOT 60
Page 1: ...Parts Manual 26616 Revision C SUPER SHOT 60 PROPANE MELTER ...
Page 4: ...Super Shot 60 Propane Trailer Melter PN 43300 Super Shot 60 Propane Skid Melter PN 50750 ...
Page 14: ......
Page 22: ......
Page 62: ......
Page 66: ......
Page 102: ......
Page 136: ......
Page 139: ......
Page 140: ... 2018 Crafco Inc ...