Super Shot 60 Propane Melter Part Manual
Chapter 5 Operating Instructions
©2018 by Crafco, Inc. All Rights Reserved
………………..…………………………………..….Operating Instructions 5-12
5.10 Overnight Heater Use
An overnight heater rod is available as an option. 24190 110V and 24194 220V. The overnight
heater may be used to maintain an overnight heat transfer oil temperature of approximately 200-
250°F (93.3°C)
Step
Action
1
Attach the heater power cord to a suitable extension cord.
2
Attach the extension cord to its own outlet rated for 15 amps minimum.
WARNING
Suitable extension cord size requirements for
110 Volt
use:
25-50 FT
• 16-20 Amps • 12 Gauge (Heavy Duty) or 10 Gauge (Extra Heavy Duty)
100 FT
• 16-20 Amps • 10 Gauge (Extra Heavy Duty)
Suitable extension cord size requirements for
220 Volt
use:
25-50 FT
• 8-10 Amps • 14 Gauge (Medium Duty) or 12 Gauge (Heavy Duty)
100 FT
• 8-10 Amps • 12 Gauge (Heavy Duty)
Failure to use the correct size extension cord could result in damage and
possible fire!
3
Disconnect the heater when using the machine’s burner system.
CAUTION
Do not use the heater without heat transfer oil in the tank. Doing so will overheat and
damage the heater, and it will have to be replaced.
Table 5-10 Overnight Heater Use
Summary of Contents for SUPER SHOT 60
Page 1: ...Parts Manual 26616 Revision C SUPER SHOT 60 PROPANE MELTER ...
Page 4: ...Super Shot 60 Propane Trailer Melter PN 43300 Super Shot 60 Propane Skid Melter PN 50750 ...
Page 14: ......
Page 22: ......
Page 62: ......
Page 66: ......
Page 102: ......
Page 136: ......
Page 139: ......
Page 140: ... 2018 Crafco Inc ...