Super Shot 60 Diesel Melter Part Manual
Chapter 8 Troubleshooting
©2016 by Crafco, Inc. All Rights Reserved
………………...………………………………..……………...Troubleshooting 8-34
Table 8-30 Pump Electrical Troubleshooting (continued)
Step
Possible Cause
If . . .
10d
Is there 12 Vdc between the "Mixer" toggle
switch center post red wire and the blue (4) wires
ground din plug?
Yes, check for a broken wire or poor wire
crimp on the red wire between the "Mixer"
toggle switch and the "Pump" toggle
switch.
No, if this is the case you would have had
an agitator problem. Call Crafco, Inc. and
speak to a service technician.
10e
Unscrew the din plug center screw so you can
pull the din plug up about 1/4", so you can check
for voltage. Is there 12 Vdc from side post to side
post, when the wand trigger is pulled?
Yes, the electrical system for the agitator is
No, recheck the amber light, if the light comes
"ON" and you do not have 12 Vdc then
replace the din plug.
Summary of Contents for SS60-Diesel
Page 1: ...Parts Manual 26618 Revision B ...
Page 4: ...SUPER SHOT 60 DIESEL SKID MOUNT MELTER PN 46800 SUPER SHOT 60 DIESEL TRAILER MELTER PN 46950 ...
Page 5: ......
Page 8: ...Super Shot 60 Diesel Melter Part Manual Table of Contents 10 0 Tools and Accessories 10 1 ...
Page 14: ......
Page 18: ......
Page 24: ......
Page 44: ......
Page 48: ......
Page 114: ......
Page 118: ......
Page 119: ... 2016 Crafco Inc ...