GENERAL INFORMATION

2

Congratulations on your purchase of the all new Pro-Set

 

®

 TRA21 Series Mobile A/C 

refrigerant recovery unit. The TRA21 can be setup for either R-134a or R-1234yf operation. 
The TRA21 utilizes CPS’s patent pending 2 cylinder oil-less compressor. The unit is 
equipped with a suction side oil separator to collect oil removed from the mobile A/C 
system. The unit also is equipped with a suction side filter drier with moisture sightglass.
Features:
• Convertible for Mobile A/C R-134a and R-1234yf systems
• Convertible for Commercial recovery
• Small High Side volume eliminates pump down system
• Fast and easy convertible instructions
• All components mounted on a heavy duty roll cage
• Easy to carry handle integrated into the roll cage
• Models TRA21, TRA21C and TRA21S include tank overfill sensor cord
• High Pressure cutout switch

This  manual  contains  important  information  on  the  proper  procedures  for  operating 
this equipment. Please pay close attention to the: Safety InformationWarnings, and 
Cautions provided throughout this manual.

ALWAYS REMEMBER “ SAFETY FIRST ”

Table of Contents

Introduction

General Information 

2-5

Introduction 

2

General Safety Instructions 

3

Specifications 

4

Unit Layout 

5

6-11

6-7

Operation 

Direct Vapor or Liquid Recovery 
Liquid Flush Recovery 
Filter Drier Maintenance 
Trouble Shooting Chart 

8-9

 

10

 

11

 

Summary of Contents for Pro-Set TRA21 Series

Page 1: ...OPERATION MANUAL Pro Set TRA21 SERIES Mobile Multiple Refrigerant Recovery Recycle System Certified by ITS to meet SAE J2810 for R 134a Designed to meet new SAE J2851 for R 1234yf ...

Page 2: ...systems Convertible for Commercial recovery Small High Side volume eliminates pump down system Fast and easy convertible instructions All components mounted on a heavy duty roll cage Easy to carry handle integrated into the roll cage Models TRA21 TRA21C and TRA21S include tank overfill sensor cord High Pressure cutout switch This manual contains important information on the proper procedures for o...

Page 3: ... heart arrhythmia loss of consciousness or even cause suffocation DANGER ELECTRICAL SHOCK HAZARD Always disconnect power source when servicing this equipment DANGER EXPLOSION RISK Do not recover flamable refrigerants CAUTION All hoses may contain liquid refrigerant under pressure Contact with refrigerant may cause frostbite or other related injuries Wear proper personal protective equipment such a...

Page 4: ...ents Included TRA21 TRA21C TRA21S TRA21E R 134a Manifold Hose Set Included Included Included 30 lb DOT Recovery with Overfill Sensor Included Included Included Overfill Sensor Cord Included Included Included Suction Hose Included Discharge Hose Included Included Included Included Oil Drain Bottle and Hose Included Included Included Included R 1234yf Low Side Coupler Included R 134a Low Side Couple...

Page 5: ...port 2 Oil drain valve and port 3 Base unit 4 High pressure indicator light 5 Overfill sensor cord and indicator light not included on the TRA21E 6 Roll cage handle 7 Discharge Port 8 Oil seperator 9 Drier with moisture indicator 6 5 5 4 3 7 9 8 2 1 ...

Page 6: ... tank 3 Connect the Yellow Overfill Sensor Cord to the float in the recovery tank This cord is not inclueded on the model TRA21E For the TRA21E use scale to monitor tank weight All connections should be done as shown in Diagram 1 4 Open the vapor valve on the recovery tank 5 Start unit by pushing main power switch to the ON position 6 Open the HI and LO side manifold valves to start the refrigeran...

Page 7: ...OPERATION Diagram 1 ...

Page 8: ...at in the recovery tank This cord is not included on the model TRA21E For the TRA21E use scale to monitor tank weight All connections should be done as shown in Diagram 2 5 Open the vapor valve on the recovery tank 6 Start unit by pushing main power switch to the ON position 7 Open the HI and LO side manifold valves to start the refrigerant flow 8 Run for 15 minutes to allow liquid refrigerant to ...

Page 9: ...Diagram 2 OPERATION ...

Page 10: ...d into the system and placed in the storage tank Liquid filter drier manitenance The TRA21 is equipped with a 16 cubic inch filter drier with an integrated moisture indicator This filter should be checked and replaced periodically This filter drier removes any moisture that may be contained in the recovered refrigerant Replace the filter drier as follows Caution Always assume the presence of high ...

Page 11: ...ts off Solution The high pressure switch has activated Make sure the discharge valve and recovery tank valve s are open Check for any other restrictions on the discharge port of the unit Correct restriction Restart the unit Problem TOS Red LED lights up and the unit shuts off or will not start Solution 1 Check to make sure TOS cord is properly plugged into the recovery tank float 2 Check tank weig...

Reviews: