The G-250XTP is designed for long, trouble-free performance and
should not require extensive troubleshooting in the field. If difficulty
is encountered, check the following:
SYMPTOM
POSSIBLE CAUSES
Failure to start
Ensure there is adequate propane in the tank.
Ensure the E-Stop button is raised.
Check battery for charge.
Check to ensure oil level is correct.
Check the speed you are starting on – starting
at a high speed is not recommended (see Best
Practices).
Stops suddenly
Ensure there is adequate propane in the tank.
Make sure that the propane tank is not over
filled. (80% maximum)
Make sure you are using a vapor draw tank.
If you are cutting next to a wall, make sure that
exhaust is pointed away from the wall.
Ensure that there is adequate ventilation.
Vacuum Not
Working
Check that hoses are fastened securely.
Head does not
turn
Check belt tension. If the engine is running, and
the head does not turn, the belt is slipping or is
broke. Contact CPS for service.
Heads spin but
housing doesn’t
If the heads run but the housing doesn’t the
pinion gear shear pin has broken. Test it by
turning one of the heads and the housing
should turn. Contact CPS for service.