Page 23
Service Hotline: 855-584-7168
CHINT POWER SYSTEMS AMERICA CO., LTD.
Email: [email protected]
Website: www.chintpowersystems.com
Flex Gateway Datasheet
Ethernet port
FOMlink port
Connections
Data Interfaces
Inverter daisy chain
Third-party data logger
CPS cloud service
Third-party server
SCADA client
RS485 port A
RS485 port B
AUX port
Isolated RS485, Max. 32 devices
AUX port, Isolated 3 Pin RS485
Internet, Primary MQTT
Internet, HTTPS or Secondary MQTT
Ethernet port, Modbus/TCP
Internal installation, RS485+DC Input, 6 Pin
External installation, RS485+DC Input, 5 Pole 3.5 mm pitch EDG
Only one effective at the same time between port A and B
RS485, 3 Pole, A+ / B- / G
RJ45, 10Base-T / 100Base-T
4Pin connector
General data
Voltage supply
4G Cellular module
WiFi module
LTE-FDD/LTE-TDD, WCDMA, GSM/EDGE
Option, 802.11 b/g/n
Input voltage
Power consumption
9 ~ 24 Vdc
< 1 W, Max. 5 W
Ambient conditions
Degree of protection
Ambient temperature
Relative humidity
Installed in inverter wire-box or NEMA4 enclosure
-40
℃
to +85
℃
, Natural convection
< 85%, Non-condensing
Dimensions ( W/H/D)
Weight
140 mm / 70 mm / 15 mm
69 g