3
)
VOX
VOX function is transmitted by detecting a voice level without Using the
PTT button VOX sensitivity level is 1 - 5 steps, you can set using the CPS
program.
4
)
Lone Worker
It is function to inform others about your safety within the time set in
the menu. Setting time supports up to 1-100 minutes.
5
)
BCL/BCLO
If the another user on the currently used channel, it is the ability to limit
the transmission so as not to interfere.
BCL: If the current channel is busy,
the transmission prohibition BCLO: The ability to send regardless of the
user of the current channel
6
)
Button Lock
With the exception of the minimum of buttons necessary for the user to
prevent unwanted terminal operation, it is the ability to limit the
operation. When the button lock is on, all buttons are locked except the
PTT button, the emergency button and power ON / OFF button. When
press the key (button lock temporary release key) for seconds,
you can use a button. After 25 seconds from you pressing the last button,
to return to the button again locked.
7
)
Sound
This is a sound setting function. The main menu is available Only
ON / OFF. The detailed sound can be set using the CPS program.
8
)
LCD Back Light
This feature is LCD backlight ON / OFF.
9
)
LCD Contrast
The function is to adjust the brightness. The brightness can be set from
1 to 7 step.
LED Status display setting. The feature is to set the LED status
display. It can be set detailed using the CPS program.
www.cps-telecom.com