Page 1: ...Cat 5 Pro Vacuum OPERATOR S MANUAL Concrete Polishing Solutions PO Box 520 Norris TN 37828 Phone 865 494 8200 Fax 865 494 8300 Toll Free 877 472 8200 www go2cps com ...

Page 2: ...logy for the concrete flooring industry Our representatives will be happy to inform you of any products or help assist you with your Polished Concrete needs We want you as our customer to understand that while we do consider our company to be the leader in research and development in this industry we are not above learning from you as you experience new and challenging obstacles on each floor surf...

Page 3: ...t be accompanied with a return authorization number and a copy of the original invoice We will then review the complaint and inspect the merchandise before a credit can be processed Any items that are returned because of obvious misuse will be shipped back to the sender at their expense and no credit shall be issued Any returned items including items under warranty must be sent at the customer s e...

Page 4: ...ions have been made to the equipment Customer Service Concrete Polishing Solutions has a well trained service department and our sales and technical staff have extensive knowledge on how to service our equipment Being the manufacturer we best understand our equipment and already have parts in stock We can also send you the parts and help you to service your own equipment over the phone In some loc...

Page 5: ... who delivered your machine The following items should be included with the delivery of your Cat 5 Pro Vac please contact Customer Service if anything is missing a Cat 5 Pro Vacuum b 100 Hose c Propane Tank d Vac Wand and Head e Longo Pack Weight 495 lbs Power Required Propane Motor 17 HP Propane Specifications Serial Number Sales Person Cell Number DELIVERY SPECIFICATIONS Concrete Polishing Solut...

Page 6: ...e and weight and provide convenient dust free disposal The practical design of the CAT 5 Propane Vacuum is equipped with a unique manually operated filter cleaning system that does not require the use of compressed air A secondary HEPA filter assembly is also a standard feature on your CAT 5 Pro vacuum to capture 99 97 of dust down to 0 3 micron particle size Start Up Your CAT 5 Pro vacuum is equi...

Page 7: ... with it to determine how long it takes to fill the collection bag The unique design of the CAT 5 Pro vacuum allows the operator to control the weight volume of the material in the collection bag to suit his individual or his company s needs The CAT 5 Pro is also a high productivity machine because it allows the operator to discharge the vacuumed debris into the continuous bag without shutting dow...

Page 8: ...ully lift off the filter cover which has the two primary cartridge filters attached Place the cover assembly on a flat work surface with the filters facing upward 5 Remove the wing nut steel washer and rubber washer from each filter mounting rod and remove the filters and dispose of them properly according to Federal state local or corporate regulations 6 Carefully place a new filter cartridge ove...

Page 9: ...s or damage replace these items before continuing vacuum operation 8 Place the filter cover assembly back on the filter housing and re install the four clamps 9 Reconnect the vacuum hose to the back of the filter cover 10 Turn your vacuum back on and resume vacuuming operation NOTES 24 7 Technical Support Toll Free 1 877 472 8200 FILTER MAINTENANCE Concrete Polishing Solutions Cat 5 Pro Vacuum Ope...

Page 10: ...ge filter out of the housing and dispose of it properly according to Federal state local or corporate regulations 4 Carefully place a new HEPA filter cartridge over the mounting rod and replace the mounting hardware exactly as shown in the photo above The rubber washer prevents dust from bypassing the filter cartridge through the mounting rod opening and entering other parts of the vacuum system o...

Page 11: ...ine service point inside the back housing is the motor junction box If your CAT 5 Pro is used as a portable vacuum regularly check your wire connections between the battery and the solinoid to make sure that they are tight Frequent moves encountered with portable equipment can result in loose wires A loose wire can result in engine not starting or machine not running correctly NOTES 11 24 7 Techni...

Page 12: ... as shown When properly installed the loose outer end of the continuous bag will face downward as shown Cut the packaging strings as shown in photo 2 Do not cut the packaging string until you have properly installed the bag set in the bag holder 3 Re install the plastic bag holder on the metal adaptor as shown in photo 3 so that the three spring steel tags lock under the holder Photo 1 Bag set in ...

Page 13: ...ed from the vacuum 4 Pull the lose outer end of the continuous bag downward and bring the edges together until there is enough material to tie it off with a tie wrap to form the bottom of the first bag as shown in photos 4 and 5 Apply one tie wrap as shown in photo 6 NOTES 13 24 7 Technical Support Toll Free 1 877 472 8200 Concrete Polishing Solutions Cat 5 Pro Vacuum Operator s Manual ...

Page 14: ...lve that opens automatically when the vacuum is shut down or a filter cleaning operation is taking place Collected debris will discharge from the primary filter housing into the collection bag CAUTION DO NOT ALLOW THE TIED OFF BAG TO INTERFERE WITH THE DISCHARGE VALVE OPENING OR CLOSING NOTES 14 24 7 Technical Support Toll Free 1 877 472 8200 CONTINUOUS BAGGING SYSTEM CON T Concrete Polishing Solu...

Page 15: ...ates maximum vacuum at 7 8 Hg and the vacuum relief valve opens Pull handle to the Backwash position which also vents the vacuum producer This can be repeated several times if necessary Push handle back to the operating position and immediately open the blocking valve on the vacuum inlet 15 24 7 Technical Support Toll Free 1 877 472 8200 Concrete Polishing Solutions Cat 5 Pro Vacuum Operator s Man...

Page 16: ...24 7 Technical Support Toll Free 1 877 472 8200 INTERNATIONAL POLISHED CONCRETE INSTITUTE LLC A CPT INSTITUTION ...