AFM100 OPERATION
7
Turn
FLUSH VALVE
to
PURGE
/
OFF
position. Turn
FLOW DIRECTION VALVE
to
FORWARD
position.
Connect shop air hose to
COMPRESSED AIR INLET PORT
located on the
back of the unit.
Open the
AIR SUPPLY VALVE
on the back of the unit.
Verify air flow by checking the air vent on the back of the unit. Air should be felt
coming out of this port. If no flow, turn the
FLOW DIRECTION VALVE
to
REVERSE
position turn. If there is still no air flow, the component may be permanently
plugged.
Once air flow is confirmed in either direction, proceed to flush procedure.
Flush Procedure:
With the
FLOW DIRECTION VALVE
in the position of verified flow, turn
FLUSH VALVE
to
FLUSH
position. The CPS solvent is now being pushed through
the component.
Monitor the Clear Bowl and both flush hoses. Once CPS solvent is present in both
hoses and is seen moving through the bowl, turn the
FLUSH VALVE
to
FLUSH HOLD
position.
Hold for
10-15 minutes
. This allows the CPS solvent to dissolve contaminants.
Turn
FLUSH VALVE
back to
FLUSH
position. Run for 1-2 minutes or until all the
solvent has passed through the component.
To
REVERSE FLUSH
, turn the
FLOW DIRECTION VALVE
to opposite position used
during flush. Run until solvent is gone.
Air Drying Procedure:
Turn the
FLUSH VALVE
to
PURGE
/
OFF
position. Turn the
FLOW DIRECTION VALVE
to the
FORWARD
position. Let air run through component for 5-10 minutes to
evaporate remaining solvent
Once air drying procedure is complete, close the
AIR SUPPLY VALVE
. Make sure
air pressure gauge reads zero before disconnecting flush hose to component.
Open Drain on the back of the unit to drain spent solvent. Dispose of solvent per
local, state, and/or federal requirements.
3.
4.
5.
6.
7.
1.
2.
3.
4.
5.
1.
2.