AFM100 OPERATION

7

Turn 

FLUSH VALVE

 to 

PURGE

/

OFF

 position. Turn 

FLOW DIRECTION VALVE

 to 

 

FORWARD

 position.

Connect shop air hose to 

COMPRESSED AIR INLET PORT

 located on the 

  back of the unit.

Open the 

AIR SUPPLY VALVE

 on the back of the unit.

Verify air flow by checking the air vent on the back of the unit. Air should be felt 

  coming out of this port. If no flow, turn the 

FLOW DIRECTION VALVE

 to 

REVERSE

 

  position turn. If there is still no air flow, the component may be permanently 

  plugged.

Once air flow is confirmed in either direction, proceed to flush procedure.

Flush Procedure:

With the 

FLOW DIRECTION VALVE

 in the position of verified flow, turn 

 

FLUSH VALVE

 to 

FLUSH

 position. The CPS solvent is now being pushed through 

  the component.

Monitor the Clear Bowl and both flush hoses. Once CPS solvent is present in both 

  hoses and is seen moving through the bowl, turn the 

FLUSH VALVE

 to 

 

FLUSH HOLD

 position.

Hold for 

10-15 minutes

. This allows the CPS solvent to dissolve contaminants.

Turn 

FLUSH VALVE

 back to 

FLUSH

 position. Run for 1-2 minutes or until all the 

  solvent has passed through the component.

To 

REVERSE FLUSH

, turn the 

FLOW DIRECTION VALVE

 to opposite position used 

  during flush. Run until solvent is gone.

Air Drying Procedure:

Turn the 

FLUSH VALVE

 to 

PURGE

/

OFF 

position. Turn the 

FLOW DIRECTION VALVE

 

  to the 

FORWARD

 position. Let air run through component for 5-10 minutes to 

  evaporate remaining solvent 

Once air drying procedure is complete, close the 

AIR SUPPLY VALVE

. Make sure 

  air pressure gauge reads zero before disconnecting flush hose to component.

 

Open Drain on the back of the unit to drain spent solvent. Dispose of solvent per 

local, state, and/or federal requirements.

3.

4.

5.

6.

7.

1.

2.

3.

4.

5.

1.

2.

Summary of Contents for afm100 series

Page 1: ...A C SOLVENT FLUSH For use with CPS SUPER FLUSH SOLVENT TO BE OPERATED BY QUALIFIED PERSONNEL ONLY OPERATION MANUAL ...

Page 2: ...erating Range 0 C 32 F to 49 C 120 F Air Pressure Gauge 0 to 100 PSIG Filtration 100 mesh cleanable screen Manual Control Valves 2 way ball type valve to control air supply to the unit 3 way ball type valve to control air Purge Flush circulation 4 way ball type valve to control Forward and Reverse flush Construction Heavy duty power coated sheet metal cabinet with 6 wheels Adaptors One set of univ...

Page 3: ...ol valve will allow the user to reverse the flow at any time The CPS Universal Flush clamps makes connecting to an A C component easy The following are additional features One set of CPS Universal Flush Clamps Easy one step hook up Air Hose and Flush Hoses Forward Reverse flush valve to eliminate reconnection of hoses Filter with clear removable bowl for flow and filtration verification Large mout...

Page 4: ...reathing solvent vapor fumes Exposure may irritate eyes nose throat and skin Please read the manufacturers material safety data sheet for further safety information on the solvent CAUTION avoid skin contact with solvent Exposure may irritate eyes nose throat and skin Please read the manufacturers material safety data sheet for further safety information on the solvent Wear proper personal protecti...

Page 5: ... unit not shown Hose storage hooks Outlet Hose A to component out fitting 6 wheels Handle Flow direction valve 1 2 3 4 5 6 7 Flush valve Outlet Hose B to component out fitting Clear bowl with cleanable filter Storage shelf Collection tank drain valve back side of unit not shown Collection tank sight glass right side of unit not shown Flush tank pressure gauge 8 9 10 11 12 13 14 1 2 3 4 5 6 7 9 10 ...

Page 6: ... tank is 2 5 gallons See following chart for flush amount to used RECOMMENDED FLUSH SOLVENT AMOUNT PER VEHICLE CAR PICKUP TRUCKS 2 Quarts DUAL AIR SYSTEMS 3 Quarts HEAVY DUTY TRUCKS 3 Quarts BUSES MOBILE HOMES etc up to 2 Gallons Once flush tank is filled to the desired amount with CPS solvent reinstall cap Make sure the cap is hand tight DO NOT USE A WRENCH TO TIGHTEN FILL CAP Purge or Flow Verif...

Page 7: ...r Bowl and both flush hoses Once CPS solvent is present in both hoses and is seen moving through the bowl turn the FLUSH VALVE to FLUSH HOLD position Hold for 10 15 minutes This allows the CPS solvent to dissolve contaminants Turn FLUSH VALVE back to FLUSH position Run for 1 2 minutes or until all the solvent has passed through the component To REVERSE FLUSH turn the FLOW DIRECTION VALVE to opposi...

Page 8: ... Reinstall filter element and secure by screwing clear bowl back onto the filter housing Check the universal flush clamp for worn seals Check hoses for worn seals THE FOLLOWING ARE SERVICEABLE PARTS FOR THE AFM100 UNIT CPS Part Number Description AFMXH Flush hose with 3 8 female SAE swivel connection AFMXHS Flush hose rubber seal set of 2 AFMXF Replacement cylindrical filters AFMXC Replacement uni...

Reviews: