TROUBLE SHOOTING 

Before calling CPR’s Technical Support, please take some time to look over this trouble  

shooting guide.  Most of the problems associated with the performance of the  

AeroForce

TM

 AP 

are due to improper maintenance of the pumps.   

Cleaning the powerhead at least once a month will ensure  

optimal performance of the 

Aero Force

TM

  

 

Pico 400 disassembly 

Problem: 

Cause and Solution:

 

Small air bubbles returning to the tank 

The surface tension of the water has been increased by added supplements, medications,  
or conditioners.  Disable the protein skimmer by submerging the airline into the water 
or shutting off the air pump for 24 hours.  Many products contain chemicals which will 
still be present in the aquarium after 24 hours.  Run the protein skimmer as normal to 
remove compounds which may be affecting surface tension. 

 

The salinity is too high.  Lower the salinity to 1.023. 

 

Adjust the red flow controller on the feed pump.  Reducing the flow will slow the flow 
rate through the skimmer, reducing the draft of bubbles into the tank.  

 

The aquarium has just been cleaned or water has been changed.  Synthetic salt mixes 
often contain conditioners which increase the surface tension of the water.  Bubbles 
should disappear within 48 hours. 

 

New substrate has recently been added.  The addition of new substrate and the silicates 
(as a result) can increase bubble production and decrease bubble size.  Perform respon-
sibly aggressive water changes to help the system process through this transition. 

No waste collecting in collection cup. 

The air pump outlet and its airline may be dirty.  Clean the whole unit every two weeks 
for optimal performance. 

 

The collection cup is not low enough.  See instructions for the correct height of the 
collection cup. 

 

The biological load may not be sufficient to generate waste.  On a new tank or a tank 
with supplemental filtration it may take over a week to generate waste foam. 

The air pump is producing little or no 
bubbles. 

The airline or the air pump outlet may be blocked.  Detritus, calcium and salt will build 
up in these parts over time.  Clean these parts every two to three weeks with warm tap 
water. 

 

The air diffusers have become clogged with organic material and the flow rate and the 
air output rates are reduced.  Clean the air diffusers with water and replace, if necessary.  

* a small, clear, translucent bushing is located inside of 

the red cap.  It can pop out during disassembly, so be 
careful to not misplace that required part.   

Summary of Contents for AeroForce AP

Page 1: ...nside of the AeroForceTM AP with warm water optional but recommended 3 Remove inner body from outer body The unit should come with the wooden air duiffusers installed on the inside of the unit Secure the two airlines coming out of the air diffusers to the air pump outlets and place the air pump in a secure location Insert the airline into the black airline clip on the side of the unit 4 Slide the ...

Page 2: ... to assist in taking the Pico pump apart During disassembly ensure that no pieces are misplaced The Pico 400 pump includes a small clear translucent bushing that the impeller rod fits into inside red cap and is required for quiet operation It can pop out so please be careful during disassembly 4 Wash Pico parts under warm tap water Do not use any detergents 5 Make sure that the air pump outlet and...

Page 3: ...contain conditioners which increase the surface tension of the water Bubbles should disappear within 48 hours New substrate has recently been added The addition of new substrate and the silicates as a result can increase bubble production and decrease bubble size Perform respon sibly aggressive water changes to help the system process through this transition No waste collecting in collection cup T...

Page 4: ...iagram A Adjustment screws 7 Pico 400 5 Collection cup 9 Inlet part 2 Support pin 6 Outlet 8 Inner body slides down into the outer body Ensure that the Inlet part 1 and Inlet part 2 are in line with each other so that water can pass through both inlet parts NOT SHOWN Air pump Airline ...

Reviews: