background image

CPR Aquatic, INC•P.O. Box 1111•3749 West End Road, Arcata, CA 95521 

AeroForce

TM

 AP (Air Pump) 

 

As many hobbyists venture into the world of reef keeping, a common goal among most is to keep the filtration 
system as simple as possible.  One of the most important components to filtration is the removal of compounds 
which could eventually break down into ammonia and nitrite.  The AeroForce

TM

 AP is designed to provide a simple yet 

highly efficient protein skimmer for a reef system.  The AeroForce

TM

 AP employs a new dual-body chamber to make 

maintenance easier and for sturdier construction. Requiring no supplemental plumbing, the AeroForce

TM 

simply 

hangs on the back of the tank and can be installed in a few short minutes. 

 

To place your AeroForce

TM

 AP into operation: 

 
1)  Carefully remove all packaging and inspect the unit for damaged or missing parts.  You should have: 
 

 

 
(1)   Outer acrylic body 
(1)  Inner protein skimmer body 
(1) Pico400 (feed pump) 
(1)   MA400 air pump 
(2)  Wooden air diffusers  
(1)  Collection cup assembly with “O” ring and lid 
(1)   Support pin  
If any items are damaged or missing, please contact your dealer immediately. 

 
2)  Rinse inside of the AeroForce

TM

 AP with warm water. (optional, but recommended) 

 

 

3)  Remove inner body from outer body.  The unit should come with the wooden air duiffusers installed on the inside 

of the unit.   Secure the two airlines coming out of the air diffusers to the air pump outlets and place the air 
pump in a secure location.  Insert the airline into the black airline clip on the side of the unit.   

 
4)  Slide the inner skimmer body into the outer body.  The inlet pipe parts 1 and 2 should line up once the two bodies 

are together (see page 4).  

 
5)  Attach the Pico4 (5) to the inlet part 2.   
 
6)  Hang the AeroForce

TM

 AP on your tank.  Use the adjustment screws (7) and support pin (6) to position the 

AeroForce

TM

 AP so that it is parallel to the back of the tank.  Insert the support pin into the desired position 

first, and then adjust the screws accordingly. 

 
7)  Clean the collection cup  (1) including the throat of the funnel in hot water. This will cause the skimmer to begin 
 

collecting waste faster.  Do not use any detergents on the collection cup.  Insert cup inside protein skimmer 

 

section with O-ring placed around the outside.  The o-ring acts as a support for the cup to rest on top of the 

 AeroForce

TM

 AP body.  This is not intended to form a seal inside the body. 

 
 

CPR Technical Support (707) 826-9636 • FAX (707) 826-9623 

www.cprusa.com • [email protected] 

Summary of Contents for AeroForce AP

Page 1: ...nside of the AeroForceTM AP with warm water optional but recommended 3 Remove inner body from outer body The unit should come with the wooden air duiffusers installed on the inside of the unit Secure the two airlines coming out of the air diffusers to the air pump outlets and place the air pump in a secure location Insert the airline into the black airline clip on the side of the unit 4 Slide the ...

Page 2: ... to assist in taking the Pico pump apart During disassembly ensure that no pieces are misplaced The Pico 400 pump includes a small clear translucent bushing that the impeller rod fits into inside red cap and is required for quiet operation It can pop out so please be careful during disassembly 4 Wash Pico parts under warm tap water Do not use any detergents 5 Make sure that the air pump outlet and...

Page 3: ...contain conditioners which increase the surface tension of the water Bubbles should disappear within 48 hours New substrate has recently been added The addition of new substrate and the silicates as a result can increase bubble production and decrease bubble size Perform respon sibly aggressive water changes to help the system process through this transition No waste collecting in collection cup T...

Page 4: ...iagram A Adjustment screws 7 Pico 400 5 Collection cup 9 Inlet part 2 Support pin 6 Outlet 8 Inner body slides down into the outer body Ensure that the Inlet part 1 and Inlet part 2 are in line with each other so that water can pass through both inlet parts NOT SHOWN Air pump Airline ...