CPG CK HPSU212 User Manual Download Page 6

6

CONVERSION

Instructions are for conversion from Natural Gas to Propane (L.P.) on all models. The conversion

should be done before connecting the unit to the gas supply.

Units are shipped from the factory equipped for use with natural gas. Orifices necessary for LP

(propane) are provided in a bag tied to the valve on the front panel.

1. Remove the knobs and front panel.

2 . Uns

2.

Remove the burner from the top 

of the gas pipe

.

1.

Remove  the  trivets  from  the 
top of the appliance

.

Note: Unit Number on side
of orifice fittings.

Plastic Insert

3. Replace the orifice

fittings into the valve.

5. Before installing the regulator,

unscrew the octagonal cap up, you can

read (NAT) on the plastic insert out of

the cap, flip it over and snap back in

6. Continue with

installation.

Regulator with brass cap

L.P Position of insert

4. Install the front

panel knobs

Summary of Contents for CK HPSU212

Page 1: ...1 USER MANUAL Gas Step Up Hot Plate MODELS CK HPSU212 CK HPSU424 CK HPSU636 06 2017...

Page 2: ...ion can be obtained from your local gas supplier CAUTION These models are designed built and sold for commercial use only If these models are positioned so the general public can use the equipment mak...

Page 3: ...ars of reliable operation from this equipment To ensure best results it is important that you read and follow the instructions in this manual carefully TABLE OF CONTENTS ITEM PAGE ITEM PAGE Safety pre...

Page 4: ...y read understands and follows these instruction If you have questions concerning the installation operation maintenance or service of this product visit Cooking Performance Group s website at www Coo...

Page 5: ...TS ARE SUITABLE FOR INSTALLATION ON NON COMBUSTIBLE SURFACES ONLY Combustible clearances 6 sides 152 mm 6 rear 152 mm 4 oor 102 mm Noncombustible clearances 0 sides 0 mm 0 rear 0 mm 4 oor 102 mm Do no...

Page 6: ...the front panel 1 Remove the knobs and front panel 2 Uns 2 Remove the burner from the top of the gas pipe 1 Remove the trivets from the top of the appliance Note Unit Number on side of ori ce ttings P...

Page 7: ...cient air supply results in a yellow streaming ame Primary air supply is controlled by an air shutter on the front of the burner 2 Loosen the screws on the front of the burner and adjust the air shut...

Page 8: ...grabbing the handle and pulling it out of the opening in the front panel To replace the pan reverse this procedure 3 Burner air shutter openings must be kept clean Main burner ports must be kept clean...

Page 9: ...9 EXPLOSION VIEW DRAWING MODEL CK HPSU424...

Page 10: ...1068643 2 4 6 CK HPSU212 LPG CK HPSU424 LPG CK HPSU636 LPG 01 20 1068652 2 4 6 6 Burner CK HPSU212 CK HPSU424 CK HPSU636 06 05 1472521 2 4 6 7 Grate CK HPSU212 CK HPSU424 CK HPSU636 01 03 1015096 2 4...

Page 11: ...PSU424 CK HPSU636 06 05 1473193 1 2 3 14 Valve connection CK HPSU212 CK HPSU424 CK HPSU636 66 04 1820085 2 4 6 15 Valve CK HPSU212 CK HPSU424 CK HPSU636 01 20 1068502 2 4 6 16 Pilot valve CK HPSU212 C...

Page 12: ...or equipment failure occurs because of accident carelessness lack of proper set up supervision when required or if the equipment is installed or operated in any manner contrary to the installation and...

Reviews: