USER MANUAL

 TROUBLESHOOTING

ISSUE

POSSIBLE CAUSES

REMEDIES

Pilot not lighting

Insufficient gas pressure in pipe

Contact local gas supply department

Nozzle occlusion

Dredge nozzle

Pilot ignited, but not 

the main burner

Insufficient gas pressure in pipe

Contact local gas supply department

Nozzle occlusion

Dredge nozzle

Gas control valves broken

Replace control valves

Low flame distance

Adjust distance

Low flame

Adjust height of pilot light

Inconsistent burning

Insufficient gas pressure in pipe

Contact local gas supply department

Nozzle does not match gas requirements

Adjust nozzle diameter

Flow of connection pipe is not adequate

Increase pipe’s allowable flow

Damper opening degree is too large

Adjust damper

Yellow flame and/or 

black smoke

Incorrect gas

Change gas

Nozzle does not match gas requirements

Adjust nozzle diameter

Not enough air to ignite

Increase damper opening degree

Gas spikes and floats

Turn down valve flow

THE PROBLEMS MENTIONED ABOVE ARE FOR REFERENCE ONLY.

IF ANY FAULT OCCURS, STOP USING THE MACHINE IMMEDIATELY AND 

CONTACT AN AUTHORIZED TECHNICIAN TO CHECK AND MAKE REPAIRS.

All manuals and user guides at all-guides.com

Summary of Contents for 351CPGSPR18L

Page 1: ...USER MANUAL Stock Pot Range MODEL 351CPGSPR18 L N 06 2017 All manuals and user guides at all guides com a l l g u i d e s c o m ...

Page 2: ... unit in compliance with this manual Any nearby walls surfaces kitchen supplies etc should be non combustible and heat resistant Please pay special attention to fire prevention regulations This user s manual contains information and guidelines collected from years of industry experience For optimal safety and efficient operation please make this document available to staff members authorized to us...

Page 3: ...supplied must be installed on the appliance prior to connecting the equipment to the gas line Failure to install a regulator could be potentially hazardous and will void the appliance warranty The appliance and its individual shut off valve must be disconnected from the gas supply piping system during any pressure testing of that system at test pressures in excess of psi 3 45kpa The appliance must...

Page 4: ...hould be made for any commercial heavy duty cooking appliance to have it its exhaust combustion waste products released to the outside of the building The usual practice is to place the appliance under an exhaust hood which should be constructed in accordance with local codes Strong exhaust fans in this hood or in the overall air conditioning system can produce a slight vacuum in the room and or c...

Page 5: ...ill have inlet outlet openings and are adjusted at the factory for 4 WC natural gas or 10 WC liquid propane gas depending on customer s ordering instructions Prior to connecting the regulator check the incoming line pressure as these regulators can only withstand a maximum pressure of psi 14 WC If the line pressure is beyond this limit a step down regulator will be required The arrow shown on the ...

Page 6: ... minute for existing gas in pipe to disperse and try again after 1 minute Turn ON gas valve s to light the main burner For complete shutdown shut OFF gas valve s and turn pilot valve s by adjusting the screw clockwise to shut off gas to the pilot s Wait 5 minutes before next use Turn off range remove all objects and disconnect energy source Remove control panel cooking grates pilot light head and ...

Page 7: ...NOT USE steel wool abrasive cloths or powders to clean stainless surfaces If it is necessary to scrape stainless steel to remove encrusted materials soak in hot water to loosen the material then use a wood or nylon scraper DO NOT USE a metal knife spatula or any other metal tool to scrape stainless steel Scratches are nearly impossible to remove Ensure your Cooking Performance Group range is check...

Page 8: ...stent burning Insufficient gas pressure in pipe Contact local gas supply department Nozzle does not match gas requirements Adjust nozzle diameter Flow of connection pipe is not adequate Increase pipe s allowable flow Damper opening degree is too large Adjust damper Yellow flame and or black smoke Incorrect gas Change gas Nozzle does not match gas requirements Adjust nozzle diameter Not enough air ...

Page 9: ...WEIGHT 120 0 Lb 120 0 Lb OF BURNERS 2 2 GAS TYPE Liquid Propane Natural Gas INTAKE TUBE PRESSURE 4 WC 10 WC BTU PER BURNER 40 000 40 000 BTU TOTAL 80 000 80 000 NOZZLE NO LP49 NG32 IGNITION TYPE Manual Manual VALVE TYPES Pilot Light Pilot Light TEMPERATURE CONTROL None None TOP GRADE DIMENSIONS 17 9 x 20 9 17 9 x 20 9 SPECIFICATIONS MAY VARY DEPENDING ON MODEL AND ARE SUBJECT TO CHANGE AT ANY TIME...

Page 10: ...10 www CookingPerformanceGroup com 1 800 678 5517 USER MANUAL EXPLODED VIEW All manuals and user guides at all guides com ...

Page 11: ...01990006 Damper cover 2 15 301081011 Stainless steel cross screws 2 16 301080007 Brass nut 0 17 301070011 Brass hoop 0 18 301050015 Brass street elbow 0 19 21106002013 Front burner outer pilot intake tube 1 20 301060003 Pilot light head 2 21 211060000000 Pilot light head stator 2 22 21106002014 Front burner inner pilot intake tube 1 23 301080008 Brass lock nut 0 24 301050014 Brass double male elbo...

Page 12: ...ersonnel or changed from our original design is not covered under this Warranty Furthermore COOKING PERFORMANCE GROUP assumes no obligation for any product which has been subject to misuse abuse or harsh chemicals Normal maintenance as outlined in the instructions is the responsibility of the owner user and is not a part of this warranty Ninety days on Cast Iron Parts Light bulbs porcelain and gla...

Page 13: ...www CookingPerformanceGroup com 13 1 800 678 5517 USER MANUAL NOTES All manuals and user guides at all guides com ...

Reviews: