5.  MAINTENANCE 

You are advised to send us your instrument for maintenance (at CPF or an authorized 
service centre) once a year. 

Normal maintenance consists of checking the calibration and cleaning the pipes. 

FOR CORRECT MAINTENANCE:  

Always use original sensors or spare parts and do not have the instrument maintained at 
unauthorized centres, otherwise the warranty shall be forfeited. 

 

REPLACING THE BATTERY 

The replaceable battery (BA045) is easy to replace. 

Turn off the instrument and 

disconnect it from the battery charger

  then open the cover at the back of the 

case

remove the battery and take off the connector.  

Next, attach the polarized connector on the new battery, put the battery in the 
compartment and re-close the cover. 
 
 

6.  TECHNICAL CHARACTERISTICS 

 

 

Pressure range 

0... +35bar 

Resolution 

0.1 bar 

Accuracy 

±1% fs 

Display 

LCD 8 characters on 2 lines 

Battery 

Li-ion 3.6Vdc 1.1 Ah 

Average battery duration 

30 hours 

Battery charging time 

4 hours 

Pneumatic connection 

M1 0x1 

Weight of the case 

Approx. 1.4 Kg 

Dimensions of the instrument 

260mm x 80mm x 35mm (excl. the sensor l =21 0mm) 

Printer 

External infrared printer; paper width 58mm 

Power  

230Vca external power supply for charging or direct 
power (also for the printer). 

Operating temperature 

-5 +60°C 

Storage temperature 

-20 +85°C 

Max applicable pressure 

65 bar 

 

AC999 conforms to the provisions of standard EN 3-7/2005 

 

Summary of Contents for AC999

Page 1: ...ssago Brescia Italy Tel 39 030 31 04 61 Fax 39 030 31 04 65 http www cpfindustraiale it e mail info cpfindustraiale it EN IST 3402 PT13 02 A File IST 3402 PT13 02_A_ENG_AC999 doc Extinguisher pressure...

Page 2: ...ruction Pag 2 16 CPF Industriale S p a Via Enrico Fermi 98 Gussago BS Tel 030 31 04 61 Fax 030 310465 IMPORTANT NOTE Please read and keep this user s instructions NOTE This manual applies to devices w...

Page 3: ...2 2 2 PRESSURE AND TEMPERATURE 6 2 2 3 UNIT OF MEASUREMENT 6 2 2 4 NOMINAL PRESSURE 7 2 2 5 PRESSURE TEST 7 2 2 6 READING THE MEMORY 7 2 2 7 ERASE THE MEMORY 7 2 2 8 PC DATA 7 3 SOFTWARE 8 3 1 INSTALL...

Page 4: ...put the appliance to any use other than the one intended by the manufacturer Keep it in a place that is neither too hot nor too cold refer to the Technical Characteristics and where there is no likeli...

Page 5: ...ts even when the battery is low To charge the battery insert the plug of the power supply in the socket on the left hand side of the AC999 The display is illuminated when the instrument is charging Th...

Page 6: ...lue displayed starting with the first digit in the top left corner Press ENTER to move the cursor to the right ESC to move the cursor back to the start and ENTER to confirm PRINTER press ENTER and the...

Page 7: ...ful or LOW if it is not Press PRINT to print the test result on a receipt Press ESC and you are asked whether to save the data press ENTER to save the data on the memory or ESC to return to the previo...

Page 8: ...er on your own pc is enabled autoplay CD ROM software installation will start automatically Otherwise run the setup exe file in the root directory of the CD ROM Select I accept the license agreement a...

Page 9: ...e that the driver installation is complete before starting the software SW999 On startup the software displays the following screen Button to download the data from the instrument Select to export and...

Page 10: ...ECTING 3 2 2 Exporting saved data from instrument memory Select whether to export to a text file or an excel file you can select both Then clicking on the RECEIVING DATA FROM MEMORY the data on the de...

Page 11: ...USING THE PRINTER How to replace the paper 1 Open the cover by lifting the transparent window 2 Remove the old roll and if necessary feed out any paper still remaining in the printer 3 Put in the new...

Page 12: ...ry charger then open the cover at the back of the case remove the battery and take off the connector Next attach the polarized connector on the new battery put the battery in the compartment and re cl...

Page 13: ...RY 7 DELETE MEMORY 8 PC DATA Main Display 0 bar ESC Memory Down key Start test Confirm Make zero Print Escape Up key Menu BUTTONS batt lev LOW BAT 2 PRESS TEMP 15 4bar 23 5 C 3 UNIT OF MEAS 5 PRESSU R...

Page 14: ...same parts unless specifically requested to do so If not possible to restore the instrument through the repair and or if the same proves to be too costly in comparison to the value of the product eval...

Page 15: ...IST 3402 PT13 02 A AC999 User instruction Pag 15 16 CPF Industriale S p a Via Enrico Fermi 98 Gussago BS Tel 030 31 04 61 Fax 030 310465 8 Note...

Page 16: ...n symbol on the appliance or pack indicates the product should be disposed of separately from other waste at the end of its useful life Segregated collection of this appliance at the end of its life i...

Reviews: