Installation
The DrumQuik
®
PRO drum insert
assembly replaces one of the
drum’s bung plugs and is torqued
and shipped as part of the drum
package.
1. Fully press dip-tube into drum insert socket.
2. Place the drum insert assembly in drum.
Dispensing
Remove the shipping plug from
the drum insert assembly, then
connect the DrumQuik PRO
coupler, locking it into place.
Vapor Management
Three vapor management options:
1. Fully open to vent vapors to the
atmosphere.
2. Connect CPC check valve (e.g. 2879800)
to allow make-up air in, without allowing
fumes to escape.
3. Connect a CPC quick disconnect coupling
for blanket gas (N
2
, CO
2
) or for pressure
dispensing.
3. Torque insert with drum wrench or 1/2" drive
torque wrench and a CPC torque socket tool
(CPC PN 2408900).
Note: Contact CPC for torque recommendations.
1. Turn shipping plug counterclockwise to remove.
(Use a large flat blade, #4 Phillips screwdriver
or coin.)
2. Insert coupler into drum insert assembly.
3. Turn the coupler locking ring clockwise until stop
is reached (approximately 2 full turns); valve is
opened during this process.
1. Vent port fully open.
2. Vent port outfitted with CPC check valve.
3. Vent port shown with CPC quick disconnect
coupling.