TSK WALL STAT KIT
OPTIONAL
(VC/VCR-
B “D”
SERIES HEATERS)
WALL THERMOSTAT INSTALLATION INSTRUCTIONS
This kit must be installed by a qualified installer or service technician.
Your heater can be re-wired to operate with a millivolt wall thermostat by your qualified installer/service person.
See wiring diagram below for correct wiring.
NOTE: Do not disconnect the wire from the blocked flue switch to the “TH” terminal on the gas valve.
STEP 1.
Turn temperature control knob to “OFF” or lowest setting.
STEP 2.
Turn gas valve control knob to “OFF”.
STEP 3.
Disconnect wire leading from
Part #80180
(Bulb Control Switch) from valve.
STEP 4.
Cut the remaining wire leading from
Part #80180
(Bulb Control Switch) to the blocked flue
switch, leaving its end connected to the blocked flue switch and leaving enough length to reach
the gas valve. Strip 1/2” of the insulation from the cut end of the wire.
STEP 5.
Connect one leg of thermostat wire to the “TH/PP” terminal on the gas valve.
STEP 6.
Connect second leg from the thermostat to the stripped wire coming from the blocked flue
switch. Secure this connection inside the heater cabinet.
STEP 7.
Secure both red wires from blocked flue switch inside heater cabinet. Make sure none of the
wires have enough slack to lay against the heat exchanger or draft hood.
STEP 8.
Remove lighting instructions P/N 91237, 91238, 91239 from back of heater and replace with
P/N 91242, 91243, 91244 lighting instructions supplied in TSK Kit.
STEP 9.
Follow lighting instructions to place heater in operation.
Page 14
REV. DATE: APRIL 2011
BLOCKED
FLUE SWITCH
THERMOSTAT
(OPTIONAL)
WIRE
NUT
(Not provided)
PILOT
GENERATOR
Summary of Contents for VC201B-D
Page 16: ......