background image

www.coyoteoutdoor.com

NON-COMBUSTIBLE 

CONSTRUCTION ONLY

Insulated Jacket NOT Required

FRONT VIEW

Combustible material can not be within 24" of the side

burners frame

This applies to all directions - horizontal & vertical

Shaded area above on "TOP VIEW" illustrates the 24"

minimum requirement (not to scale for rendering

purposes)

The grill is designed to hang from the counter top with

no support underneath

Ventilation Requirements:

 

Regardless if you are using a combustible or non-combustible building material, you must include at least two vents within the island.

These vents must be at least 20 sq. in. each and allow fresh air to move from the grill cabinet to the exterior environment.

For a propane setup, the vents should be installed lower as propane is heavier than air.

For a natural gas setup, the vents should be located higher in the island, as natural gas is lighter than air.

Do not locate the two vents on the same wall of the island. Cross ventilation is key to allow any excess heat or trapped gas to dissipate.

C1

D

B

   INSTALL GUIDE

OPENING 

HEIGHT

CUTOUT

WIDTH

TOP VIEW

24"

24"

COUNTERTOP

OVERHANG

SIDE

BURNER 

OPENING

24"

3/4" 

20 1/4" 

11 7/8" 

10 1/4" 

INCLUDING 

COUNTERTOP

DOORS / DRAWERS 

OPENING WIDTH

OPENING

HEIGHT

1 1/2" MIN

Important Note to Installer: 

This file is not intended to replace your Owners' Manual which contains specific safety requirements and 

consumer guidelines. Please refer to your Owners' Manual prior to installing or operating your built-in side burner.

3"

3"

3"

COMBUSTIBLE 

CONSTRUCTION

Insulated Jacket Required

 Model # CJAKTC1DB

FRONT VIEW

OPENING 

HEIGHT

CUTOUT

WIDTH

TOP VIEW

COUNTERTOP

OVERHANG

SIDE

BURNER 

OPENING

7/8"

22 1/4"

15 1/2"

11"

INCLUDING 

COUNTERTOP

DOORS / DRAWERS 

OPENING WIDTH

OPENING

HEIGHT

1 1/2" MIN

3"

3"

3"

If using combustible material within 24" of the grill frame,

you MUST use

 

the corresponding Coyote Insulated Jacket

Using a insulated jacket, does not waive any other standard

installation

 

procedure (ventilation, connections, etc)

The jacket is designed to hang from the counter top with no

support

 

underneath