Disassembling and refitting
Coway co., Ltd
4-11
No.
Part name
Explanation
Reference picture
6
Cold water
thermistor
4) Remove the tape and separate
the press sealant.
5) Remove the 2 screws and
separate the thermistor.
: 2 screw tapping (THT2, 4x10,
MSWR, Ni-P)
7
Water level
sensor
1) Separate the low water level
sensor (yellow) and full water
level sensor (red) by undoing
the two fixing nuts using an
adjustable spanner.
8
Overflow
sensor
1) Remove the 2 rubber tubes
and then separate the overflow
sensor.
CHP-06EL-eng.indb 11
2007-10-19 ソタネト 1:04:27