33
Water Filtration System Performance data Sheet
brand: metro
model: CHP-04Al
This system has been tested and certified by the Water Quality Association according to NSF/ANSI 42, 53, and 58 for
the reduction of the substances listed below. The concentration of the indicated substances in water entering the
system was reduced to a concentration less than or equal to the permissible limit for water leaving the system, as
specified in NSF/ANSI 42, 53, and 58
Substance
Max. Allowable
Concentration
(mg/L)
Average
Influent
(mg/L)
Average
Effluent
(mg/L)
Minimum
Percent
Reduction (%)
Average
Percent
Reduction (%)
Arsenic (Pentavalant)
0.010
0.05
0.006
79.1
87.7
Barium
2.0
10
1.4
83.5
86.6
Radium 226/228
5pCi/L
25pCi/L
5pCi/L
N/A
N/A
Cadmium
0.005
0.031
0.002
89.0
92.7
Chromium (Hexavalent)
0.1
0.358
0.023
93.8
95.1
Chromium (Trivalent)
0.1
0.367
0.028
93.8
95.7
Lead
0.010
0.153
0.005
93.6
95.1
Nitrate/Nitrite
10
29.6
4.8
78.5
83.7
Selenium
0.05
0.117
0.003
96.0
97.8
TDS
<187.5
741.5
55.1
90.0
92.6
Aesthetic Chlorine
INNOSENSE
≥ 50%
2.07
0.56
54.53
72.8
FINE POST CARBON
≥ 50%
1.96
0.53
55.0
72.8
VOC*
INNOSENSE
≥ 95% reduction
0.327
0.0052
96.20
98.4
FINE POST CARBON
≥ 95% reduction
0.317
0.005
96.2
98.5
While testing was performed under laboratory conditions, actual performance may vary.
General Operating information:
Rated Capacity
INNOSENSE FILTER
359 gallons (for VOC)
7,523 gallons (for Aesthetic Chlorine)
FINE POST-CARBON
402 gallons (for VOC)
1,453 gallons (for Aesthetic Chlorine)
Min-Max operating pressure:
20 ~ 120 psi (14 ~ 8.4 kgf/cm
2
)
Min-Max feed water temperature:
41 ~ 95 ºF (5 ~ 35 ºC)
Rated Service Flow
0.07 GPM (for VOC)
0.5 GPM (for Aesthetic Chlorine)
Daily Water Production Rate
53.3 GPD
Product Efficiency Rating
31.0 %
Electrical Requirements:
120 Vac / 60Hz
• Do not use with water that is microbiologically unsafe or of unknown quality without adequate disinfection
before or after the system.
• Refer to the owners manual for specific installation instructions, manufacturer’s limited warranty, user
responsibility, and parts and service availability.
• The influent water to the system shall include the following characteristics:
o No organic solvents
o Chlorine: < 2 ppm
o pH: 7 - 8
o Temperature: 41 ~ 95 ºF (5 ~ 35 ºC)
o Iron: < 2 ppm
o Turbidity: < 1 NTU
o Hardness: < 1000 mg/L
Summary of Contents for CHP-04AR