background image

Bidet

•  This product can not be used if the voltage is different from that 

mentioned in the rating plate.

•  For your safety and proper use of the product, please read this 

User’s Manual before use.

•  Warranty card is included in this User’s Manual.

BA07-R/E

1014692 BA07 »ç¿ë¼³¸í¼- ¹ÌÁÖÇâ_(08.09.10).indd   1

2008-09-10   ¿ÀÀü 11:35:34

Summary of Contents for BA07-E

Page 1: ...not be used if the voltage is di erent from that mentioned in the rating plate For your safety and proper use of the product please read this User s Manual before use Warranty card is included in this...

Page 2: ...tic function In the case there is an abnormality in the product function the indicators on the control panel blink to indicate the abnormality 4 Nozzle position adjustment The user can adjustment the...

Page 3: ...duct 19 CLEANING METHOD 21 Nozzles 21 Product Body 21 Uninstallation the Product 22 MAINTENANCE 23 Freezing Protection Function 23 FILTER REPLACEMENT METHOD 24 OTHERS TROUBLESHOOTING 25 SPECIFICATION...

Page 4: ...connect and pull out the power plug repeatedly Otherwise electric shock or re may occur as a result If the electric outlet is wet carefully unplug the unit and let the electric outlet completely dry...

Page 5: ...e Otherwise malfunctions or accidents may occur as a result Make sure to connect to cold tap water pipe After installation make sure to check the water supply connections for leaks Rubber packing shou...

Page 6: ...er outlet with a hand Otherwise burns or re may occur as a result Please turn o the main water supply valve when you replace the lter Otherwise electric shock or product damage may occur as a result F...

Page 7: ...water valve and call the Coway Service Center Don t separate the bidet body and the bidet seat Otherwise electric shock re or product damage may occur as a result Do not disassemble repair or modify...

Page 8: ...ilet that does not meet these dimensional requirements Round type 133 3 mm 5 25 inch 376 7 mm 14 8 inch 490 mm 19 3 inch 400 mm 15 7 inch 197 2 mm 7 76 inch 133 3 mm 5 25 inch 406 7 mm 16 inch 490 mm...

Page 9: ...E Seat cover Precautions sticker Nozzle Bidet seat Indication part operation part T shaped connector Bidet hose Tap water pipe Water tank hose Body Main water supply valve Power plug Product sticker N...

Page 10: ...which the product connected must be 120 V 60 Hz with an minimum current rating of 10 A The outlet must be properly installed and grounded and have three slot receptacle shown bellows If it is necessa...

Page 11: ...if you set the power saving mode After passing about 1 minute The warm water seat temperature setting becomes as a Low status After passing about 30 minutes The product is switched to the power savin...

Page 12: ...r performance deteriorates resulting in cleansing water that is not ltered properly Please keep the lter replacement cycle Filter replacement cycle Every 4 months If the bidet has not been used for a...

Page 13: ...n Water pressure air dryer temperature indicator Rear cleansing function selection button WIDE function selection button Air dryer function selection button Front cleansing function selection button 1...

Page 14: ...ure adjustment indicator When you press the seat temperature adjustment button the temperature lamp is turn on L Green M Orange H Red O Operation Part 1 Stop button Stops all operating functions 2 Noz...

Page 15: ...clean the more widen areas 9 Nozzle cleaning button Use it when you want to clean the nozzle If you press the nozzle cleaning button as the nozzle come forth and stop you can clean conveniently See P...

Page 16: ...k and forth providing a wider range of cleansing It will be worked continuously while the cleansing function is operated You can adjust the nozzle position by pressing the nozzle position button To st...

Page 17: ...roviding a wider range of cleansing It will be worked continuously while the cleansing function is operated You can adjust the nozzle position by pressing the nozzle position button To stop the move f...

Page 18: ...ge Cold water pipe Make sure to connect the bidet to cold water pipe If the product is connected to warm water pipe the lter and hoses of the bidet may be damaged To maintain the optimal product perfo...

Page 19: ...ped connector Please insert the rubber packing between the water pipe and the T shaped connectior necessarily Firmly rotate the nuts below and on top of the T shaped connector to the end clockwise 3 P...

Page 20: ...ible If the bidet hose is long it may cause noises 7 Open the main water supply valve 8 Connect the power plug to the electrical outlet Make sure to use a grounded electrical outlet In the case of sho...

Page 21: ...sing nozzle retracts itself If no button is pressed for 2 minutes after the nozzle cleaning starts the nozzle retracts itself automatically Product body Apply the neutral detergent to a soft cloth or...

Page 22: ...roduct again after draining 5 Please separate the product from the xing plate by pulling out it forward Please pull out the power plug and separate the bidet hose before separating the product When st...

Page 23: ...the power is turned on If the power is turned o the anti freezing program does not work and the bidet may have freezing burst or malfunctions in a cold environment CLEANING METHOD Uninstallation the...

Page 24: ...ve 2 Separate the MF lter from the lter holder by rotating the MF lter to replace to the arrow direction 3 Please rotate and insert new MF lter to the lter holder like the next arrow direction to the...

Page 25: ...d with water after installation before water can be ejected The water pressure is weak Is the water pressure set too low Adjust the water pressure properly Is the nozzle clogged with foreign material...

Page 26: ...tween the nozzles after cleansing is to clean the nozzles not a malfunction In some cases water drops around the nozzles may fall down in the toilet It is that the water drops remaining on the nozzle...

Page 27: ...eating prevention Warm air dryer Warm air temperature control 3 levels Timing Air dryer 2 min Power consumption of dryer heater 210 W Safety device Bimetal temperature fuse overheating prevention Warm...

Page 28: ...28 MEMO...

Page 29: ...29 Others MEMO...

Page 30: ...ions other than those speci cally identi ed in the preceding section COWAY is not responsible or liable for personal injury or property damage of any kind even if arising from a breach of this Warrant...

Page 31: ...ut prior written approval of COWAY c The OWNER has noti ed COWAY in writing of any failure of the Product covered by this Warranty within thirty 30 days following such failure d There has been no misu...

Page 32: ...http www coway com 1014692 001 MADE IN KOREA...