HDMI & VGA SWITCHER/HDBT EXTENDER - S2MBW-120
Page 13
Uploading new EDID
To upload a new EDID, go to the setup tab of the Configuration and Control software. Once there select
which input’s EDID you would like to change by checking one of the boxes at the bottom of the screen. Use
the “Browse” button to locate the EDID file you would like use and finish the upload by pressing the “UpDate”
button.
Reading the current EDID
To read a copy of the current EDID, go to the setup tab of the Configuration and Control software. Once there
select which input’s EDID you would like to copy by checking one of the boxes at the bottom of the screen.
Finally, press the “Read” button and save the file with the name you wish.
Factory Reset
Holding the front panel button, sending the reset command, or using the “Restore” button within the configu-
ration software will all Reset the S2MBW-120 to the original factory settings. After performing a reset, the
unit must be power-cycled so that all of the changes take effect.