Quick Start Guide
QSG EIP LEMCOM EN (v04-2020) - 6 -
VI- COVAL BUS ADDRESS ASSIGNMENT
Standalone secondary module or modules of a “secondary only” island are factory set to address
#16 to avoid any address conflict.
User must assign a valid and unique address
(#1 to #15) to each secondary module to
make them “visible” on the COVAL bus. LEMCOM Manager software or web server can be used
to complete this operation.
1- Wire the modules.
Connect secondary module(s) to the master LEMCOM module using M8/M8 female cables.
2- Connect to the master module using LEMCOM Manager software.
Default password:
coval
3- Assign an address.
Click on the button of the first blank slot, then click OK.
4- Follow the instructions.
5- Repeat these steps
with a different address for each secondary module that is to be add-
ed to the COVAL bus.
NOTES
-
Press and hold SET button (on a secondary module) during power-up to reinitialize its
address to #16 (release the button when MS LED starts flashing).
-
Access to “Configuration Mode” in LEMCOM Manager is password-protected. Default
password is :
coval