NOTICE NEVER operate pump with discharge 

valve completely closed. Pump can destroy itself if 

run with discharge shut off (“deadheaded”).
NOTICE To avoid sand-locking pump, follow 

procedure below when starting pump for the 

first time. NEVER start a pump with discharge 

completely open unless you have done this 

procedure first.

1.  Connect a pipe elbow, a short length of pipe 

and a gate valve to pump discharge at well 

head (see Figure 10).

2.  Mount fused disconnect switch, motor control 

box (3-wire pump), or magnetic starter 

(1-1/2HP 3-wire pump) in a permanently 

weather proofed place. Make sure that controls 

will not be subjected to extreme heat or 

excess moisture.

3.  Make sure controls are in OFF position.

4.  Connect motor leads and power supply to 

fused disconnect switch, motor control box, 

or magnetic starter (see Figure 1). Do not start 

pump yet.

5.  Set gate valve on discharge 1/3 open; start 

pump (see Figure 10).

6.  Keep gate valve at this setting while water 

pumps out on ground. Let it run until water is 

clear of sand or silt. To check solids in water, fill 

a glass from pump and let solids settle out.

7.  When water is completely clear at 1/3 setting, 

open gate valve to approximately 2/3 open and 

repeat process.

8.  When water is completely clear at 2/3 setting, 

open gate valve completely and run pump until 

water is completely clear.

9.  Remove gate valve for permanent installation 

near tank (see Figures 11 and 12).

10. Install sanitary well seal or pitless adapter unit, 

well unit, electrical conduit and surface piping 

according to local code requirements.

C onnecting to Tank / 

Water System

 Risk of explosion . Submersible 

pumps can develop very high pressure in some 

situations. To prevent tank failure, install a 

pressure relief valve able to pass full pump flow 

at 75 PSI (517 kPa) when using an air over water 

pressure tank. Install a pressure relief valve 

capable of passing entire pump flow at 100 PSI 

(690 kPa) when using a pre-charged pressure 

tank. Install this relief valve between pump 

and tank.
NOTICE Allowing pump or piping system to 

freeze may severely damage pump and will void 

warranty. Protect pump and entire piping system 

(including pressure tank) from freezing.
Standard Tank Hookup:
See Figure 11 for piping connections to standard 

pressure tank and for correct distance of bleeder 

orifices from pressure tank.

Pre-charged Pressure Tank Hookup:
See Figure 12 for piping connections to pre-

charged pressure tank.
NOTICE Check air pre-charge in tank before 

starting pump. Adjust pre-charge to 2 PSI 

(13.8 kPa) below pump cut-in setting. (For 

example, a pre-charge tank used with a 30-50 

switch should be pre-charged with air to 28 PSI 

(193 kPa)). Adjust pre-charge by either adding or 

bleeding air through air pressure valve located 

on top of tank. Check pre-charge annually and 

adjust as needed.

Electrical Grounding Information

 Risk of electric shock . Can shock, 

burn or kill. To reduce the risk of electrical 

shock during pump operation, ground and bond 

the pump and motor as follows:

• 

To reduce risk of electrical shock from metal 

parts of the assembly other than the pump, bond 

together all metal parts accessible at the well 

head (including metal discharge pipe, metal 

well casing, and the like). Use a metal bonding 

conductor at least as large as the power cable 

conductors running down the well to the pump’s 

motor.

•  Clamp or weld this bonding conductor to the 

grounding means provided with the pump, which 

will be the equipment-grounding terminal, the 

grounding conductor on the pump housing, or an 

equipment-grounding lead (the conductor having 

green insulation).

•  Ground the pump, motor, and any metallic 

conduit that carries power cable conductors. 

Ground these back to the service by connecting 

a copper conductor from the pump, motor, and 

conduit to the grounding screw provided within 

the supply-connection box wiring compartment. 

This conductor must be at least as large as the 

circuit conductors supplying the pump.

Figure 10 - Typical pump start-up

Control

box

or

electrical

disconnect

box

Temporary wiring

to control box or

electrical disconnect box

Temporary piping

Gate valve

Pump in well

6470 1111

Pump installation

for developing a well

Summary of Contents for 102890199

Page 1: ...v 01 06 17 Installation Operation Parts For further operating installation or maintenance assistance Call 800 535 4950 English Pages 2 12 Instalaci n Operaci n Piezas Para mayor informaci n sobre el f...

Page 2: ...n must meet United States National Electrical Code Canadian Electrical Code and local codes as applicable for all wiring Disconnect electrical power supply before installing or servicing pump Make sur...

Page 3: ...rge as wires carrying current to motor See Table 1 for recommended fuses and also see Cable Splicing Motor is supplied with copper ground wire Splice to copper conductor that matches motor wire size s...

Page 4: ...rload trips look for 1 Shorted capacitor 2 Voltage problems 3 Overloaded or locked pump NOTICE Use only control box specified for your pump Make sure motor and control box match Table 3 Failure to do...

Page 5: ...Make four passes with the tape when finished you should have four layers of tape tightly wrapped around the wire Press edges of tape firmly down against the wire see Figure 5 NOTICE Since the tightly...

Page 6: ...ed in designated location Most submersible motors will include a ground lead for connection Other motors will have designated location on motor bracket 4 Use only submersible cable supplied by pump ma...

Page 7: ...s relief valve between pump and tank NOTICE Allowing pump or piping system to freeze may severely damage pump and will void warranty Protect pump and entire piping system including pressure tank from...

Page 8: ...on Submersible motor control 3 wire models Electrical disconnect Pressure gauge Air volume control Pressure switch To house service Gate valve Relief valve 2 ft 6 m See table 6472 1111 Figure 11 Typic...

Page 9: ...s Electrical disconnect Pre charged tank Pressure switch Pressure gauge To house service Relief valve Union Gate valve 6471 1111 Figure 12 Typical Pre Charge Tank Installation Cut In PSI Cut Off PSI P...

Page 10: ...ontrol box Check control box wiring diagram against incoming power hookup Reconnect leads to match wiring diagram in control box cover Check drop cable color coding Reconnect drop cable so cable color...

Page 11: ...ee valve if installed backwards reverse it Low water level Determine lowest water level in well while pump is running and compare to pump depth setting Lower pump further into well but at least 5 1 6m...

Page 12: ...l rental applications Sewage Pumps DO NOT return a sewage pump that has been installed to your retail store Contact CountyLine Customer Service Sewage pumps that have seen service and been removed car...

Page 13: ...de instalar la bomba o de realizar tareas de reparaci n y mantenimiento Verifique que la tensi n de l nea y la frecuencia del suministro de corriente el ctrica coincidan con la tensi n y la frecuenci...

Page 14: ...alme del cable El motor viene equipado con un cable de cobre de puesta a tierra Empalme este cable a tierra a un conductor de cobre que concuerde con el tama o del hilo del motor especificado en los T...

Page 15: ...se dispara verifique que no haya 1 Un capacitor en corto circuito 2 Problemas de tensi n 3 Bomba sobrecargada o bloqueada AVISO Use solamente la caja de control dise ada para usar con la bomba Aseg r...

Page 16: ...ase la cinta cuatro veces Es decir cuando termine tendr cuatro capas de cinta envueltas firmemente alrededor del cable Presione los bordes de la cinta firmemente contra el cable consulte la Figura 5 A...

Page 17: ...otores sumergibles incluyen un conductor a tierra para la conexi n Otros motores tendr n un lugar designado en el soporte del motor 4 Use solamente cables sumergibles suministrados por el fabricante d...

Page 18: ...tanque AVISO Si se permite que la bomba o el sistema de tuber as se congelen existe el riesgo de provocar da os graves en la bomba y esto invalidar la garant a Proteja la bomba y todo el sistema de tu...

Page 19: ...que est ndar Distancia de la v lvula de retenci n al orificio de purga superior Capacidad del tanque en galones l distancia en pies m 42 159 2 6 82 310 4 3 9 120 454 2 5 1 5 Uni n V lvula de alivio V...

Page 20: ...ol box 3 wire models Electrical disconnect Pre charged tank Pressure switch Pressure gauge To house service Relief valve Union Gate valve 6471 1111 Figura 12 Instalaci n t pica para un tanque de presi...

Page 21: ...n de corriente el ctrica de entrada Vuelva a conectar los conductores para que coincidan con el diagrama de cableado en la tapa de la caja de control Verifique los c digos de color del cable de segre...

Page 22: ...nivel del agua Determine el nivel m s bajo de agua en el pozo cuando la bomba est marchando y comp relo con la graduaci n de profundidad de la bomba Baje la bomba a mayor profundidad en el pozo pero...

Page 23: ...productos utilizados en aplicaciones comerciales o de alquiler Bombas cloacales NO devuelva una bomba cloacal que se haya instalado a su tienda minorista Comun quese con el Departamento de Atenci n al...

Page 24: ......

Reviews: